Comparison of finger plethysmograph to ECG in the measurement of heart rate variability
The DOI matches its Crossref record.
Abstract
Two experiments compared finger plethysmograph (FP) to electrocardiogram (ECG) in providing accurate heart periods for use in heart rate variability (HRV) calculations. In Experiment 1, simultaneous ECG and FP recordings were taken from 16 healthy subjects at rest. In Experiment 2, 10 additional healthy subjects were recorded at rest and during the Stroop Color-Word Test. In both studies, high correlations were found between FP-derived and ECG-derived band variance for high and low frequency HRV at rest. But, during the Stroop task, correlations were strongly diminished. In addition, under both conditions, HRV measures were significantly higher using the FP signal. Thus, FP may be adequate for determining HRV at rest, but, for experimental use, ECG may still be recommended. Nonetheless, further studies that include test-retest reliability assessment of both data collection techniques are warranted before a more certain determination can be made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shaffer, F., McCraty, R., & Zerr, C. L. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01040 · Cited by 1,866
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Selvaraj, N., Jaryal, A., Santhosh, J., Deepak, K. K., & Anand, S. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701781317 · Cited by 342
The psychophysiology of flow during piano playing.
de Manzano, Ö., Theorell, T., Harmat, L., & Ullén, F. (2010) · Emotion · doi:10.1037/a0018432 · Cited by 330
A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
Shaffer, F., Meehan, Z. M., & Zerr, C. L. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594880 · Cited by 248
Mejía-Mejía, E., Budidha, K., Abay, T. Y., May, J. M., & Kyriacou, P. A. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00779 · Cited by 171
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160
A Practical Guide to Resonance Frequency Assessment for Heart Rate Variability Biofeedback
Shaffer, F., & Meehan, Z. M. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.570400 · Cited by 133
Thurber, M. R., Bodenhamer-Davis, E., Johnson, M., Chesky, K., & Chandler, C. K. (2010) · Biofeedback · doi:10.5298/1081-5937-38.1.28 · Cited by 74
Evaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis
Barrios, L., Oldrati, P., Santini, S., & Lutterotti, A. (2019) · Proceedings of the 13th EAI International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3329189.3329215 · Cited by 43
“[15] found good agreement between the HRV metrics obtained from a finger plethysmograph and an ECG with three leads.”
Metadata
- Authors
- GIARDINO, N. D., LEHRER, P. M., & EDELBERG, R.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2002-03
- Volume
- 39
- Issue
- 2
- Pages
- 246-253
- ISSN
- 0048-5772 (ISSN-L)
- OpenAlex
- W2120969014
- Cited by
- 132
- References
- 0
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.