The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Sensitive Immunosensor for Cancer Biomarker Based on Dual Signal Amplification Strategy of Graphene Sheets and Multienzyme Functionalized Carbon Nanospheres
Open accessAbstract
A novel electrochemical immunosensor for sensitive detection of cancer biomarker alpha-fetoprotein (AFP) is described that uses a graphene sheet sensor platform and functionalized carbon nanospheres (CNSs) labeled with horseradish peroxidase-secondary antibodies (HRP-Ab2). Greatly enhanced sensitivity for the cancer biomarker is based on a dual signal amplification strategy: first, the synthesized CNSs yielded a homogeneous and narrow size distribution, which allowed several binding events of HRP-Ab2 on each nanosphere. Enhanced sensitivity was achieved by introducing the multibioconjugates of HRP-Ab2-CNSs onto the electrode surface through "sandwich" immunoreactions. Second, functionalized graphene sheets used for the biosensor platform increased the surface area to capture a large amount of primary antibodies (Ab1), thus amplifying the detection response. On the basis of the dual signal amplification strategy of graphene sheets and the multienzyme labeling, the developed immunosensor showed a 7-fold increase in detection signal compared to the immunosensor without graphene modification and CNSs labeling. The proposed method could respond to 0.02 ng mL(-1) AFP with a linear calibration range from 0.05 to 6 ng mL(-1). This amplification strategy is a promising platform for clinical screening of cancer biomarkers and point-of-care diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Systems biology: a brief overview
Kitano, H. (2002) · Science · doi:10.1126/science.1069492 · Cited by 4,265
Single Sheet Functionalized Graphene by Oxidation and Thermal Expansion of Graphite
McAllister, M. J., Li, J.-L., Adamson, D. H., Schniepp, H. C., Abdala, A. A., Liu, J., Herrera-Alonso, M., Milius, D. L., Car, R., Prud'homme, R. K., et al. (2007) · Chemistry of Materials · doi:10.1021/cm0630800 · Cited by 3,569
Self-citationFunctionalized Single Graphene Sheets Derived from Splitting Graphite Oxide
Schniepp, H. C., Li, J.-L., McAllister, M. J., Sai, H., Herrera-Alonso, M., Adamson, D. H., Prud'homme, R. K., Car, R., Saville, D. A., & Aksay, I. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp060936f · Cited by 3,476
Self-citationAdvanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Colloidal Carbon Spheres and Their Core/Shell Structures with Noble‐Metal Nanoparticles
Sun, X., & Li, Y. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200352386 · Cited by 2,193
Electrochemical Sensing and Biosensing Platform Based on Chemically Reduced Graphene Oxide
Zhou, M., Zhai, Y., & Dong, S. (2009) · Analytical Chemistry · doi:10.1021/ac900136z · Cited by 1,706
Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene
Shan, C., Yang, H., Song, J., Han, D., Ivaska, A., & Niu, L. (2009) · Analytical Chemistry · doi:10.1021/ac802193c · Cited by 1,315
Glucose Oxidase–graphene–chitosan modified electrode for direct electrochemistry and glucose sensing
Kang, X., Wang, J., Wu, H., Aksay, I. A., Liu, J., & Lin, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.004 · Cited by 1,229
Self-citationShang, N. G., Papakonstantinou, P., McMullan, M., Chu, M., Stamboulis, A., Potenza, A., Dhesi, S. S., & Marchetto, H. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200800951 · Cited by 812
Biomolecule‐Functionalized Carbon Nanotubes: Applications in Nanobioelectronics
Katz, E., & Willner, I. (2004) · ChemPhysChem · doi:10.1002/cphc.200400193 · Cited by 749
Enzyme immunoassays with special reference to ELISA techniques.
Voller, A., Bartlett, A., & Bidwell, D. E. (1978) · Journal of Clinical Pathology · doi:10.1136/jcp.31.6.507 · Cited by 700
Preparation and electrochemical performance for methanol oxidation of pt/graphene nanocomposites
Li, Y., Tang, L., & Li, J. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.02.009 · Cited by 689
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Probing the Electrochemical Properties of Graphene Nanosheets for Biosensing Applications
Alwarappan, S., Erdem, A., Liu, C., & Li, C.-Z. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp9010313 · Cited by 616
Mani, V., Chikkaveeraiah, B. V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800863w · Cited by 532
Metal Nanoparticle-Based Electrochemical Stripping Potentiometric Detection of DNA Hybridization
Wang, J., Xu, D., Kawde, A.-N., & Polsky, R. (2001) · Analytical Chemistry · doi:10.1021/ac0107148 · Cited by 526
Self-citationBiomedical and clinical applications of immunoassays and immunosensors for tumor markers
Wu, J., Fu, Z., Yan, F., & Ju, H. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.05.007 · Cited by 461
Polsky, R., Gill, R., Kaganovsky, L., & Willner, I. (2006) · Analytical Chemistry · doi:10.1021/ac0519864 · Cited by 459
Trends in biomarker research for cancer detection
Srinivas, P. R., Kramer, B. S., & Srivastava, S. (2001) · The Lancet Oncology · doi:10.1016/s1470-2045(01)00560-5 · Cited by 411
Authier, L., Grossiord, C., Brossier, P., & Limoges, B. (2001) · Analytical Chemistry · doi:10.1021/ac0103221 · Cited by 328
Hydrothermal Dehydration of Aqueous Fructose Solutions in a Closed System
Yao, C., Shin, Y., Wang, L.-Q., Windisch, Samuels, W. D., Arey, B. W., Wang, C., Risen, & Exarhos, G. J. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp074188l · Cited by 303
Self-citationDehydration Reactions of Carbohydrates
Feather, M. S., & Harris, J. F. (1973) · Advances in Carbohydrate Chemistry and Biochemistry · doi:10.1016/s0065-2318(08)60383-2 · Cited by 228
Cui, R., Liu, C., Shen, J., Gao, D., Zhu, J., & Chen, H. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701340 · Cited by 220
High-sensitivity miniaturized immunoassays for tumor necrosis factor ? using microfluidic systems
Cesaro-Tadic, S., Dernick, G., Juncker, D., Buurman, G., Kropshofer, H., Michel, B., Fattinger, C., & Delamarche, E. (2004) · Lab on a Chip · doi:10.1039/b408964b · Cited by 203
Wang, J., Liu, G., Engelhard, M. H., & Lin, Y. (2006) · Analytical Chemistry · doi:10.1021/ac060809f · Cited by 174
Self-citationHydrothermal Syntheses of Colloidal Carbon Spheres from Cyclodextrins
Shin, Y., Wang, L., Bae, I., Arey, B. W., & Exarhos, G. J. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp801343y · Cited by 149
Self-citationDetection of Protein Analytes via Nanoparticle-Based Bio Bar Code Technology
Bao, Y. P., Wei, T.-F., Lefebvre, P., et al. (2006) · Analytical Chemistry · doi:10.1021/ac051798d · Cited by 144
Cheng, W., Ding, L., Lei, J., Ding, S., & Ju, H. (2008) · Analytical Chemistry · doi:10.1021/ac800199t · Cited by 140
Radioimmunoassay of tumor necrosis factor in serum.
Teppo, A.-M., & Maury, C. P. J. (1987) · Clinical Chemistry · doi:10.1093/clinchem/33.11.2024 · Cited by 139
Radioimmunoassay: Review of basic principles
Goldsmith, S. J. (1975) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(75)80028-6 · Cited by 123
Matsuya, T., Tashiro, S., Hoshino, N., et al. (2003) · Analytical Chemistry · doi:10.1021/ac034346e · Cited by 112
Electrochemical Quantification of Single-Nucleotide Polymorphisms Using Nanoparticle Probes
Liu, G., & Lin, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja070429r · Cited by 105
Self-citationSaito, K., Kobayashi, D., Sasaki, M., Araake, H., Kida, T., Yagihashi, A., Yajima, T., Kameshima, H., & Watanabe, N. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.5.665 · Cited by 103
Saito, K., Kobayashi, D., Sasaki, M., Araake, H., Kida, T., Yagihashi, A., Yajima, T., Kameshima, H., & Watanabe, N. (1999) · PubMed · Cited by 96
Niederkofler, E. E., Tubbs, K. A., Gruber, K. F., Nedelkov, D., Kiernan, U. A., Williams, P., & Nelson, R. W. (2001) · Analytical Chemistry · doi:10.1021/ac010143j · Cited by 85
Shen, G. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh932 · Cited by 48
Wang, J., Liu, G., Wu, H., & Lin, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.01.024 · Cited by 41
Self-citation
Cited by
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Zhu, C., Du, D., Eychmüller, A., & Lin, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00255 · Cited by 672
Self-citationXu, S., Liu, Y., Wang, T., & Li, J. (2011) · Analytical Chemistry · doi:10.1021/ac200237j · Cited by 367
Liu, Q., Shi, J., Zeng, L., Wang, T., Cai, Y., & Jiang, G. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.11.022 · Cited by 317
Metadata
- Authors
- Du, D., Zou, Z., Shin, Y., Wang, J., Wu, H., Engelhard, M. H., Liu, J., Aksay, I. A., & Lin, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-04
- Volume
- 82
- Issue
- 7
- Pages
- 2989-2995
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047806434
- Cited by
- 448
- References
- 38
- FWCI
- 48.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.