The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
β-Galactosidase-Based Colorimetric Paper Sensor for Determination of Heavy Metals
Abstract
We demonstrate a novel approach for rapid, selective, and sensitive detection of heavy metals using a solid-phase bioactive lab-on-paper sensor that is inkjet printed with sol-gel entrapped reagents to allow colorimetric visualization of the enzymatic activity of β-galactosidase (B-GAL). The bioactive paper assay is able to detect a range of heavy metals, either alone or as mixtures, in as little as 10 min, with detection limits as follows: Hg(II) = 0.001 ppm; Ag(I) = 0.002 ppm, Cu(II) = 0.020 ppm; Cd(II) = 0.020 ppm; Pb(II) = 0.140 ppm; Cr(VI) = 0.150 ppm; Ni(II) = 0.230 ppm. The paper-based assay was immune to interferences from nontoxic metal ions such as Na(+) or K(+), could be used to detect heavy metals that were spiked into tap water or lake water, and provided quantitative data that was in agreement with values obtained by atomic absorption. With the incorporation of standard chromogenic metal sensing reagents into a multiplexed bioactive paper sensor, it was possible to identify specific metals in mixtures, albeit with much lower detection limits than were obtained with the enzymatic assay. The paper-based sensor should be valuable for rapid, on-site screening of trace levels of heavy metals in resource limited areas and developing countries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in metal-induced oxidative stress and human disease
Jomova, K., & Valko, M. (2011) · Toxicology · doi:10.1016/j.tox.2011.03.001 · Cited by 3,207
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
Development, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Paper-Based Bioassays Using Gold Nanoparticle Colorimetric Probes
Zhao, W., Ali, M. M., Aguirre, S. D., Brook, M. A., & Li, Y. (2008) · Analytical Chemistry · doi:10.1021/ac801008q · Cited by 338
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Soil Sensors and Plant Wearables for Smart and Precision Agriculture
Yin, H., Cao, Y., Marelli, B., Zeng, X., Mason, A. J., & Cao, C. (2021) · Advanced Materials · doi:10.1002/adma.202007764 · Cited by 522
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Razzak, S. A., Faruque, M. O., Alsheikh, Z., Alsheikhmohamad, L., Alkuroud, D., Alfayez, A., Hossain, S. M. Z., & Hossain, M. M. (2022) · Environmental Advances · doi:10.1016/j.envadv.2022.100168 · Cited by 462
Self-citationYamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.037 · Cited by 434
Chiu, D. T., deMello, A. J., Di Carlo, D., Doyle, P. S., Hansen, C., Maceiczyk, R. M., & Wootton, R. C. R. (2017) · Chem · doi:10.1016/j.chempr.2017.01.009 · Cited by 347
Chen, Z., Zhang, Z., Qi, J., You, J., Ma, J., & Chen, L. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129889 · Cited by 319
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Biosensors for wastewater monitoring: A review
Ejeian, F., Etedali, P., Mansouri-Tehrani, H.-A., Soozanipour, A., Low, Z.-X., Asadnia, M., Taheri-Kafrani, A., & Razmjou, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.019 · Cited by 287
Paper based diagnostics for personalized health care: Emerging technologies and commercial aspects
Mahato, K., Srivastava, A., & Chandra, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.001 · Cited by 280
Metadata
- Authors
- Hossain, S. M. Z., & Brennan, J. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-27
- Volume
- 83
- Issue
- 22
- Pages
- 8772-8778
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2334049801
- Cited by
- 297
- References
- 20
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.