The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
β-Galactosidase-Based Colorimetric Paper Sensor for Determination of Heavy Metals
Abstract
We demonstrate a novel approach for rapid, selective, and sensitive detection of heavy metals using a solid-phase bioactive lab-on-paper sensor that is inkjet printed with sol-gel entrapped reagents to allow colorimetric visualization of the enzymatic activity of β-galactosidase (B-GAL). The bioactive paper assay is able to detect a range of heavy metals, either alone or as mixtures, in as little as 10 min, with detection limits as follows: Hg(II) = 0.001 ppm; Ag(I) = 0.002 ppm, Cu(II) = 0.020 ppm; Cd(II) = 0.020 ppm; Pb(II) = 0.140 ppm; Cr(VI) = 0.150 ppm; Ni(II) = 0.230 ppm. The paper-based assay was immune to interferences from nontoxic metal ions such as Na(+) or K(+), could be used to detect heavy metals that were spiked into tap water or lake water, and provided quantitative data that was in agreement with values obtained by atomic absorption. With the incorporation of standard chromogenic metal sensing reagents into a multiplexed bioactive paper sensor, it was possible to identify specific metals in mixtures, albeit with much lower detection limits than were obtained with the enzymatic assay. The paper-based sensor should be valuable for rapid, on-site screening of trace levels of heavy metals in resource limited areas and developing countries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in metal-induced oxidative stress and human disease
Jomova, K., & Valko, M. (2011) · Toxicology · doi:10.1016/j.tox.2011.03.001 · Cited by 3,207
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
Development, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Paper-Based Bioassays Using Gold Nanoparticle Colorimetric Probes
Zhao, W., Ali, M. M., Aguirre, S. D., Brook, M. A., & Li, Y. (2008) · Analytical Chemistry · doi:10.1021/ac801008q · Cited by 338
Hossain, S. M. Z., Luckham, R. E., McFadden, M. J., & Brennan, J. D. (2009) · Analytical Chemistry · doi:10.1021/ac901714h · Cited by 316
Self-citationRoles of dioxins and heavy metals in cancer and neurological diseases using ROS-mediated mechanisms
Matés, J. M., Segura, J. A., Alonso, F. J., & Márquez, J. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.07.028 · Cited by 286
Thread as a Versatile Material for Low-Cost Microfluidic Diagnostics
Li, X., Tian, J., & Shen, W. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am9006148 · Cited by 275
Luminescent bacterial sensor for cadmium and lead
Tauriainen, S., Karp, M., Chang, W., & Virta, M. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00027-x · Cited by 240
Metering the Capillary-Driven Flow of Fluids in Paper-Based Microfluidic Devices
Noh, H., & Phillips, S. T. (2010) · Analytical Chemistry · doi:10.1021/ac100431y · Cited by 203
Feldmann, J., Salaün, P., & Lombi, E. (2009) · Environmental Chemistry · doi:10.1071/en09018 · Cited by 111
Evaluation of a microplate assay specific for heavy metal toxicity
Bitton, G., Jung, K., & Koopman, H. F. J. M. (1994) · Archives of Environmental Contamination and Toxicology · doi:10.1007/bf00203883 · Cited by 105
Senillou, A., Jaffrezic-Renault, N. J., Martelet, C., & Cosnier, S. (1999) · Talanta · doi:10.1016/s0039-9140(99)00122-8 · Cited by 92
Determination of cadmium and lead in human biological samples by spectrometric techniques: a review
Lemos, V. A., & de Carvalho, A. L. (2009) · Environmental Monitoring and Assessment · doi:10.1007/s10661-009-1276-z · Cited by 81
Multienzyme electrochemical sensor array for determination of heavy metal ions
Кукла, А. Л., Kanjuk, N. I., Starodub, N. F., & Shirshov, Y. M. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00153-7 · Cited by 65
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Soil Sensors and Plant Wearables for Smart and Precision Agriculture
Yin, H., Cao, Y., Marelli, B., Zeng, X., Mason, A. J., & Cao, C. (2021) · Advanced Materials · doi:10.1002/adma.202007764 · Cited by 522
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Metadata
- Authors
- Hossain, S. M. Z., & Brennan, J. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-27
- Volume
- 83
- Issue
- 22
- Pages
- 8772-8778
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2334049801
- Cited by
- 297
- References
- 20
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.