Mass Spectrometry Compatible Surfactant for Optimized In-Gel Protein Digestion
The DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.
Abstract
Identification of proteins resolved by SDS-PAGE depends on robust in-gel protein digestion and efficient peptide extraction, requirements that are often difficult to achieve. A lengthy and laborious procedure is an additional challenge of protein identification in gel. We show here that with the use of the mass spectrometry compatible surfactant sodium 3-((1-(furan-2-yl)undecyloxy)carbonylamino)propane-1-sulfonate, the challenges of in-gel protein digestion are effectively addressed. Peptide quantitation based on stable isotope labeling showed that the surfactant induced 1.5-2 fold increase in peptide recovery. Consequently, protein sequence coverage was increased by 20-30%, on average, and the number of identified proteins saw a substantial boost. The surfactant also accelerated the digestion process. Maximal in-gel digestion was achieved in as little as one hour, depending on incubation temperature, and peptides were readily recovered from gel eliminating the need for postdigestion extraction. This study shows that the surfactant provides an efficient means of improving protein identification in gel and streamlining the in-gel digestion procedure requiring no extra handling steps or special equipment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously, acid-cleavable surfactants such as Rapigest [28], ProteaseMAX [29], and MS-compatible degradable surfactant MaSDeS [30] were developed as MS-compatible surfactants to enable protein solubilization for digestion and MS-analysis.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [29]
Citations
Cites
In-gel digestion for mass spectrometric characterization of proteins and proteomes
Shevchenko, A., Tomas, H., Havli, J., Olsen, J. V., & Mann, M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.468 · Cited by 4,942
HaloTag: A Novel Protein Labeling Technology for Cell Imaging and Protein Analysis
Los, G. V., Encell, L. P., McDougall, M. G., Hartzell, D. D., Karassina, N., Zimprich, C., Wood, M. G., Learish, R., Ohana, R. F., Urh, M., et al. (2008) · ACS Chemical Biology · doi:10.1021/cb800025k · Cited by 2,624
Self-citationAnalysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Yu, Y.-Q., Gilar, M., Lee, P. J., Bouvier, E. S. P., & Gebler, J. C. (2003) · Analytical Chemistry · doi:10.1021/ac0346196 · Cited by 313
Katayama, H., Nagasu, T., & Oda, Y. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.379 · Cited by 240
Ultra Fast Trypsin Digestion of Proteins by High Intensity Focused Ultrasound
López-Ferrer, D., Capelo, J. L., & Vázquez, J. (2005) · Journal of Proteome Research · doi:10.1021/pr050112v · Cited by 160
Culver, B. P., Savas, J. N., Park, S. K., Choi, J. H., Zheng, S., Zeitlin, S. O., Yates, J. R., & Tanese, N. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.359307 · Cited by 150
Shieh, I.-F., Lee, C.-Y., & Shiea, J. (2005) · Journal of Proteome Research · doi:10.1021/pr049765m · Cited by 94
Mass Spectrometry of Intracellular and Membrane Proteins Using Cleavable Detergents
Norris, J. L., Porter, N. A., & Caprioli, R. M. (2003) · Analytical Chemistry · doi:10.1021/ac034802z · Cited by 73
Kinetic characterization of sequencing grade modified trypsin
Finehout, E. J., Cantor, J. R., & Lee, K. H. (2005) · PROTEOMICS · doi:10.1002/pmic.200401268 · Cited by 70
Research works printed but not linked: 2
- Speicher K. D., 2000, J. Biomol. Tech., 11, 74
- Srinivasan S., 2010, Invest. Ophthalmol. Vis. Sci., 51, 5200
Cited by
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Novel Strategies to Address the Challenges in Top-Down Proteomics
Melby, J. A., Roberts, D. S., Larson, E. J., Brown, K. A., Bayne, E. F., Jin, S., & Ge, Y. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00099 · Cited by 190
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
“Previously, acid-cleavable surfactants such as Rapigest [28], ProteaseMAX [29], and MScompatible degradable surfactant MaSDeS [30] were developed as MS-compatible surfactants to enable protein solubilization for digestion and MS-analysis.”
BackgroundKirmiz, M., Vierra, N. C., Palacio, S., & Trimmer, J. S. (2018) · Journal of Neuroscience · doi:10.1523/jneurosci.0893-18.2018 · Cited by 130
“Gel bands were prepared essentially as described previously (Saveliev et al., 2013).”
MethodWang, H., Deng, G., Ai, M., Xu, Z., Mou, T., Yu, J., Liu, H., Wang, S., & Li, G. (2019) · Oncogene · doi:10.1038/s41388-018-0532-5 · Cited by 117
Verrastro, I., Pasha, S., Jensen, K., Pitt, A., & Spickett, C. (2015) · Biomolecules · doi:10.3390/biom5020378 · Cited by 114
“MS friendly surfactant additives, such as ProteaseMax (Promega) [15,16] and Rapigest (Waters) [17], and on-membrane [18] or in-pellet digestion [15] have all been shown to”
Kharade, S. S., & McBride, M. J. (2013) · Journal of Bacteriology · doi:10.1128/jb.01170-13 · Cited by 124
“Enzymatic in-gel digestion and mass spectrometric analysis of the peptides were performed at the University of Wisconsin—Madison Mass Spectrometry Facility essentially as previously described (33, 34).”
MethodA photocleavable surfactant for top-down proteomics
Brown, K. A., Chen, B., Guardado-Alvarez, T. M., Lin, Z., Hwang, L., Ayaz-Guner, S., Jin, S., & Ge, Y. (2019) · Nature Methods · doi:10.1038/s41592-019-0391-1 · Cited by 111
New Mass-Spectrometry-Compatible Degradable Surfactant for Tissue Proteomics
Chang, Y.-H., Gregorich, Z. R., Chen, A. J., Hwang, L., Guner, H., Yu, D., Zhang, J., & Ge, Y. (2015) · Journal of Proteome Research · doi:10.1021/pr5012679 · Cited by 80
Zhu, Y., & McBride, M. J. (2013) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-013-5355-2 · Cited by 76
Updates of the In‐Gel Digestion Method for Protein Analysis by Mass Spectrometry
Goodman, J. K., Zampronio, C. G., Jones, A. M. E., & Hernandez-Fernaud, J. R. (2018) · PROTEOMICS · doi:10.1002/pmic.201800236 · Cited by 59
Shen, S., An, B., Wang, X., Hilchey, S. P., Li, J., Cao, J., Tian, Y., Hu, C., Jin, L., Ng, A. Y. H., et al. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02172 · Cited by 58
Li, Y., & Lee, J. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.02.024 · Cited by 58
Emergence of mass spectrometry detergents for membrane proteomics
Behnke, J., & Urner, L. H. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04584-z · Cited by 54
“Furthermore, these detergents show good solubilizing properties and can accelerate trypsin activity for the benefit of the digest [38, 39].”
BackgroundShen, Q., Xiong, T., Zheng, W., Luo, Y., Peng, W., Dai, J., Song, R., Li, Y., Liu, S., Li, B., et al. (2022) · Food Research International · doi:10.1016/j.foodres.2022.111326 · Cited by 50
Proteome analysis of tissues by mass spectrometry
Đapić, I., Baljeu‐Neuman, L., Uwugiaren, N., Kers, J., Goodlett, D. R., & Corthals, G. L. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21598 · Cited by 53
“One example is sodium 3‐((1‐(furan‐2‐yl)undecyloxy)‐carbonylamino)propane‐1‐sulfonate (ProteaseMAX), an anionic surfactant that contains a sulfonate group and is structurally similar to SDS, which allowed rapid digestion of membrane proteins like bacteriorhodopsin (Saveliev et al., 2013).”
BackgroundHigh‐Throughput Proteomics Enabled by a Photocleavable Surfactant
Brown, K. A., Tucholski, T., Eken, C., Knott, S. J., Zhu, Y., Jin, S., & Ge, Y. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201915374 · Cited by 47
Vasseur, M. L., Friedman, J. R., Jost, M., Xu, J., Yamada, J., Kampmann, M., Horlbeck, M. A., Salemi, M., Phinney, B. S., Weissman, J. S., et al. (2021) · eLife · doi:10.7554/elife.67624 · Cited by 43
“Gel slices were air-dried before overnight ProteaseMax-aided digestion as previously described (Saveliev et al., 2013).”
MethodLin, S., Lin, T., & Fuh, M. (2013) · Electrophoresis · doi:10.1002/elps.201300415 · Cited by 34
Gemperline, D. C., Marshall, R. S., Lee, K.-H., Zhao, Q., Hu, W., McLoughlin, F., Scalf, M., Smith, L. M., & Vierstra, R. D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.ra119.010219 · Cited by 32
“Proteins were digested overnight at 37 °C with 1 g of sequencing grade modified porcine trypsin (Promega) together with ProteaseMAX surfactant (66).”
MethodĐapić, I., Uwugiaren, N., Jansen, P. J., & Corthals, G. L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01937 · Cited by 31
Donaghy, D., & Moore, A. R. (2020) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2020.110014 · Cited by 31
Streng, A. S., de Boer, D., Bouwman, F. G., Mariman, E. C. M., Scholten, A., van Dieijen‐Visser, M. P., & Wodzig, W. K. W. H. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2015.12.028 · Cited by 30
Effects of site-specific phosphorylation on the mechanical properties of ovalbumin-based hydrogels
Xiong, Z., Ma, M., Jin, G., & Xu, Q. (2017) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.05.028 · Cited by 28
Hu, W., Zhang, X., Shen, Y., Meng, X., Wu, Y., Tong, P., Li, X., Chen, H., & Gao, J. (2024) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.70029 · Cited by 28
Calligaris, M., Zito, G., Busà, R., Bulati, M., Iannolo, G., Gallo, A., Carreca, A. P., Cuscino, N., Castelbuono, S., Carcione, C., et al. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1385712 · Cited by 27
“…mM Tris/HCl 8 M urea pH 8), proteins were digested with 0.3 µg LysC (Promega) in UC (25 mM Tris/HCl 2 M urea pH 8) for 16 h at 37 ° C followed by a second digestion step with 0.15 µg trypsin in 50 mM ammonium bicarbonate (Promega) for 4 h at 37 ° C as previously described (Saveliev et al., 2013).”
MethodInfluentialZhang, W., Yuan, Z., Huang, L., Kang, J., Jiang, R., & Zhong, H. (2016) · Scientific Reports · doi:10.1038/srep20981 · Cited by 16
Improving long circulation and procoagulant platelet targeting by engineering of hirudin prodrug
Han, H.-H., Zhang, H., Wang, R., Yan, Y., Liu, X., Wang, Y., Zhu, Y., & Wang, J. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119869 · Cited by 16
Tutorial review for peptide assays: An ounce of pre-analytics is worth a pound of cure
Maurer, J., Grouzmann, E., & Eugster, P. J. (2023) · Journal of Chromatography B · doi:10.1016/j.jchromb.2023.123904 · Cited by 16
Nonionic, Cleavable Surfactant for Top-Down Proteomics
Brown, K. A., Gugger, M. K., Yu, Z., Moreno, D., Jin, S., & Ge, Y. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03916 · Cited by 15
High‐Throughput Proteomics Enabled by a Photocleavable Surfactant
Brown, K. A., Tucholski, T., Eken, C., Knott, S., Zhu, Y., Jin, S., & Ge, Y. (2020) · Angewandte Chemie · doi:10.1002/ange.201915374 · Cited by 14
Shen, F., Xiong, Y., Zhang, L., Li, H., Zhao, H., Liu, X., & Yang, P. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03985 · Cited by 13
Surfactant-Induced Artifacts during Proteomic Sample Preparation
Ji, Y., Liu, M., Bachschmid, M. M., Costello, C. E., & Lin, C. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00249 · Cited by 13
Wang, S., Wang, R., Li, G. Q., Cho, J., Deng, Y., & Li, Y. (2020) · Journal of Proteomics · doi:10.1016/j.jprot.2020.104001 · Cited by 12
Terhaar, H. M., Henriksen, M. D. L., Uhl, L. K., Boeckling, C., Mehaffy, C., Hess, A. M., & Lappin, M. R. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273449 · Cited by 14
Identification of a TeO32− reductase/mycothione reductase fromRhodococcus erythropolisPR4
Butz, Z. J., Hendricks, A. R., Borgognoni, K. M., & Ackerson, C. J. (2020) · FEMS Microbiology Ecology · doi:10.1093/femsec/fiaa220 · Cited by 11
“(Saveliev et al. 2013) Briefly, the gel pieces were washed with 200 μL of LC-MS Grade Water (Optima LC-MS, Fisher Scientific, Pittsburgh, PA) for 30 s and destained with 2 × 200 μL of 50% Acetonitrile (ACN; Optima LCMS Grade)/50 mM Ammonium bicarbonate at 60◦C, with intermittent mixing.”
MethodHwang, L., Guardado‐Alvarez, T. M., Ayaz‐Güner, Ş., Ge, Y., & Jin, S. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b00658 · Cited by 11
Identification and Characterization of the Lactating Mouse Mammary Gland Citrullinome
Li, G., Young, C. H., Snow, B., Christensen, A. O., Demoruelle, M. K., Nemmara, V. V., Thompson, P. R., Rothfuss, H. M., & Cherrington, B. D. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21072634 · Cited by 11
“Gel fragments were subjected to in-gel trypsin digestion and LC-MS/MS as previously described [46].”
MethodLiu, H., Guo, J., Li, Y., Zhang, Y.-S., Wang, J., Gao, J., Deng, Y., & Li, Y. (2020) · Molecules · doi:10.3390/molecules25194391 · Cited by 11
Zhang, T., de Vries, M. P., Permentier, H. P., & Bischoff, R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01039 · Cited by 9
Rehkamp, A., Tänzler, D., Tüting, C., Kastritis, P. L., Iacobucci, C., Ihling, C. H., Kipping, M., Koch, K., & Sinz, A. (2021) · Journal of Molecular Biology · doi:10.1016/j.jmb.2021.166947 · Cited by 9
Huo, Y., Liu, K., & Lou, X. (2020) · Talanta · doi:10.1016/j.talanta.2020.121524 · Cited by 9
RapiGest precipitation depends on peptide concentration
Mosen, P., Hardt, R., & Winter, D. (2021) · PROTEOMICS · doi:10.1002/pmic.202100129 · Cited by 8
“While deoxycholate can be removed by liquid phase extraction [9,13], ProteaseMax and RapiGest require a step that separates their hydrophobic and hydrophilic moieties, which is achieved by tryptic cleavage [11] or acid hydrolysis [12], respectively.”
BackgroundMethodInfluentialEngineering a “three-in-one” hirudin prodrug to reduce bleeding risk: A proof-of-concept study
Zhu, Y., Han, H.-H., Zhai, L., Yan, Y., Liu, X., Wang, Y., Lei, L., & Wang, J. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.08.058 · Cited by 6
Brown, K. A., Gugger, M. K., Roberts, D. S., Moreno, D., Chae, P. S., Ge, Y., & Jin, S. (2023) · Langmuir · doi:10.1021/acs.langmuir.2c02820 · Cited by 6
Label-free quantitative proteomics of rat liver exposed to simulated microgravity
Chen, B., Li, G. Q., Li, Y., Cho, J., Wang, J., Gao, J., Deng, Y., & Li, Y. (2020) · Acta Astronautica · doi:10.1016/j.actaastro.2020.02.007 · Cited by 6
Böcker, J. K., Dörner, W., & Mootz, H. D. (2018) · Biological Chemistry · doi:10.1515/hsz-2018-0367 · Cited by 5
Ying, G., He, Y., Yang, M., Lü, G., Li, Y., Cui, W., Hu, Z., & Zhang, Z. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c04857 · Cited by 2
High Concentration Trypsin Assisted Fast In-Gel Digestion for Phosphoproteome Analysis
Liu, F., Ye, M., Pan, Y., & Zou, H. (2015) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(15)60864-7 · Cited by 2
N-terminal toxin signal peptides efficiently load therapeutics into a natural nano-injection systemPreprint
Steiner, E. M., Ejaz, R. N., Kielkopf, C. S., Pérez‐Ruiz, M., Marín-Arraiza, L., Hendriks, I. A., Nissen, J. N., Pozdnyakova, I., Pape, T., Regaiolo, A., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.11.13.566157 · Cited by 2
The Structural Proteins of Bdellovibrio bacteriovorus Bacteriophage MAC-1
Ranu, R. S., Gallegos, R., Althauser, M., & Wolfe, L. M. (2016) · World Journal of Engineering and Technology · doi:10.4236/wjet.2016.43b002 · Cited by 1
“After rehydration in LC-MS grade water, the gel fragments were then subjected to in-gel trypsin digestion for LC-MS/MS as previously described [25].”
MethodTargeted Protein Biomarker Quantitation by LC‐MS
Pang, Y., Shi, C., & Jian, W. (2017) · Wiley eBooks · doi:10.1002/9781119413073.ch15 · Cited by 1
Lee, M. C. G. (2014) · Summit (Simon Fraser University) · Cited by 1
Wang, Y. (2017) · Digital Repository Service (Northeastern University) · doi:10.17760/d20252417
Improved Protein Characterizations using Ionic Liquids: PAGE and MALDI-MS
Vidanapathirana, P. (2017) · Louisiana State University · doi:10.31390/gradschool_dissertations.4234
Novel Protein Secretion and Chitin Utilization Machinery of Flavobacterium Johnsoniae
Kharade, S. S. (2014) · UWM Digital Commons (University of Wisconsin–Milwaukee)
Nanoproteomics: An Approach for the Identification of Molecular Targets Associated with Hypoxia
Priya, J. D. A., Malik, S., Khalid, M., & Gautam, A. (2023) · Smart nanomaterials technology · doi:10.1007/978-981-99-1718-1_8
Proteomic Point of View to Tissue Engineering and Regenerative Medicine
Ekiz, M. Ş., & Çelikbıçak, Ö. (2024) · Tissue repair and reconstruction · doi:10.1007/978-981-97-7600-9_4
Protocols for Proteomic Analysis: Isolation, Solubilization and Hydrolysis by Proteases
Obukhova, E. N., Khryapova, E. V., Novikova, S. E., Kazieva, L. S., Tikhonova, O. V., & Zgoda, V. G. (2025) · Biomedical Chemistry Research and Methods · doi:10.18097/bmcrm00277
Quantitative Determination of Casein in Facial Masks Labeled as Containing Milk by UHPLC‐ESI‐QqQ‐MS
Dong, Z., Luo, J., Wang, L., Li, M., Cao, J., & Sun, S. (2026) · Journal of Separation Science · doi:10.1002/jssc.70346
Guzeloglu, A., Bishop, J. V., Campen, H. V., Davis, J. S., Diaz, G., & Hansen, T. R. (2026) · Biology of Reproduction · doi:10.1093/biolre/ioag067
“Gel fragments that were collected following immunoprecipitation of endometrial extracts with rbISG15 antibody (described above) were subjected to in-gel trypsin digestion and LC–MS/MS as previously described [ 19].”
Identification, caractérisation et validation de biomarqueurs liés à l’immunothérapie allergénique
Caillot, N. (2015) · theses.fr (ABES) · doi:10.70675/98f70acdz10e3z41fez8434zc21404ec5613
West Nile virus: viral dynamics within the avian host and host-targeted transmission control
Savran, M. J., Foy, B. D., Ebel, G. D., Bosco‐Lauth, A. M., & Titcomb, G. (2026) · doi:10.25675/3.027520
Metadata
- Authors
- Saveliev, S. V., Woodroofe, C. C., Sabat, G., Adams, C. M., Klaubert, D., Wood, K., & Urh, M.
- Affiliations
- Promega (United States) (US)
- University of Wisconsin–Madison (US)
- Stanford University (US)
- Corresponding author
- Saveliev, Sergei V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-07
- Volume
- 85
- Issue
- 2
- Pages
- 907-914
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1970731237
- Cited by
- 62
- References
- 18
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 6 · 2022: 2 · 2021: 5 · 2020: 12 · 2019: 5 · 2018: 5 · 2017: 6 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 3
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Organic Chemistry › Chemical Synthesis and Analysis
- Keywords
- SDS-PAGE, peptide extraction, peptide recovery, protein identification, protein sequence coverage, stable isotope labeling, peptide quantification
- MeSH terms
- Gels, Proteins, Surface-Active Agents, Molecular Structure, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.