CoChat

Mass Spectrometry Compatible Surfactant for Optimized In-Gel Protein Digestion

The DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.

Abstract

Identification of proteins resolved by SDS-PAGE depends on robust in-gel protein digestion and efficient peptide extraction, requirements that are often difficult to achieve. A lengthy and laborious procedure is an additional challenge of protein identification in gel. We show here that with the use of the mass spectrometry compatible surfactant sodium 3-((1-(furan-2-yl)undecyloxy)carbonylamino)propane-1-sulfonate, the challenges of in-gel protein digestion are effectively addressed. Peptide quantitation based on stable isotope labeling showed that the surfactant induced 1.5-2 fold increase in peptide recovery. Consequently, protein sequence coverage was increased by 20-30%, on average, and the number of identified proteins saw a substantial boost. The surfactant also accelerated the digestion process. Maximal in-gel digestion was achieved in as little as one hour, depending on incubation temperature, and peptides were readily recovered from gel eliminating the need for postdigestion extraction. This study shows that the surfactant provides an efficient means of improving protein identification in gel and streamlining the in-gel digestion procedure requiring no extra handling steps or special equipment.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac302423t

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Research works printed but not linked: 2

  1. Speicher K. D., 2000, J. Biomol. Tech., 11, 74
  2. Srinivasan S., 2010, Invest. Ophthalmol. Vis. Sci., 51, 5200

Cited by

Metadata

Authors
Saveliev, S. V., Woodroofe, C. C., Sabat, G., Adams, C. M., Klaubert, D., Wood, K., & Urh, M.
Affiliations
  • Promega (United States) (US)
  • University of Wisconsin–Madison (US)
  • Stanford University (US)
Corresponding author
Saveliev, Sergei V.
Venue
Analytical Chemistry
Published
2013-01-07
Volume
85
Issue
2
Pages
907-914
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1970731237
Cited by
62
References
18
Citations by year
2026: 2 · 2025: 2 · 2024: 4 · 2023: 6 · 2022: 2 · 2021: 5 · 2020: 12 · 2019: 5 · 2018: 5 · 2017: 6 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 3
FWCI
1.27
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Organic Chemistry › Chemical Synthesis and Analysis
Keywords
SDS-PAGE, peptide extraction, peptide recovery, protein identification, protein sequence coverage, stable isotope labeling, peptide quantification
MeSH terms
Gels, Proteins, Surface-Active Agents, Molecular Structure, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.