Mass Spectrometry Compatible Surfactant for Optimized In-Gel Protein Digestion
The DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.
Abstract
Identification of proteins resolved by SDS-PAGE depends on robust in-gel protein digestion and efficient peptide extraction, requirements that are often difficult to achieve. A lengthy and laborious procedure is an additional challenge of protein identification in gel. We show here that with the use of the mass spectrometry compatible surfactant sodium 3-((1-(furan-2-yl)undecyloxy)carbonylamino)propane-1-sulfonate, the challenges of in-gel protein digestion are effectively addressed. Peptide quantitation based on stable isotope labeling showed that the surfactant induced 1.5-2 fold increase in peptide recovery. Consequently, protein sequence coverage was increased by 20-30%, on average, and the number of identified proteins saw a substantial boost. The surfactant also accelerated the digestion process. Maximal in-gel digestion was achieved in as little as one hour, depending on incubation temperature, and peptides were readily recovered from gel eliminating the need for postdigestion extraction. This study shows that the surfactant provides an efficient means of improving protein identification in gel and streamlining the in-gel digestion procedure requiring no extra handling steps or special equipment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously, acid-cleavable surfactants such as Rapigest [28], ProteaseMAX [29], and MS-compatible degradable surfactant MaSDeS [30] were developed as MS-compatible surfactants to enable protein solubilization for digestion and MS-analysis.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [29]
Citations
Cites
In-gel digestion for mass spectrometric characterization of proteins and proteomes
Shevchenko, A., Tomas, H., Havli, J., Olsen, J. V., & Mann, M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.468 · Cited by 4,942
HaloTag: A Novel Protein Labeling Technology for Cell Imaging and Protein Analysis
Los, G. V., Encell, L. P., McDougall, M. G., Hartzell, D. D., Karassina, N., Zimprich, C., Wood, M. G., Learish, R., Ohana, R. F., Urh, M., et al. (2008) · ACS Chemical Biology · doi:10.1021/cb800025k · Cited by 2,624
Self-citationAnalysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Yu, Y.-Q., Gilar, M., Lee, P. J., Bouvier, E. S. P., & Gebler, J. C. (2003) · Analytical Chemistry · doi:10.1021/ac0346196 · Cited by 313
Katayama, H., Nagasu, T., & Oda, Y. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.379 · Cited by 240
Ultra Fast Trypsin Digestion of Proteins by High Intensity Focused Ultrasound
López-Ferrer, D., Capelo, J. L., & Vázquez, J. (2005) · Journal of Proteome Research · doi:10.1021/pr050112v · Cited by 160
Culver, B. P., Savas, J. N., Park, S. K., Choi, J. H., Zheng, S., Zeitlin, S. O., Yates, J. R., & Tanese, N. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.359307 · Cited by 150
Shieh, I.-F., Lee, C.-Y., & Shiea, J. (2005) · Journal of Proteome Research · doi:10.1021/pr049765m · Cited by 94
Mass Spectrometry of Intracellular and Membrane Proteins Using Cleavable Detergents
Norris, J. L., Porter, N. A., & Caprioli, R. M. (2003) · Analytical Chemistry · doi:10.1021/ac034802z · Cited by 73
Kinetic characterization of sequencing grade modified trypsin
Finehout, E. J., Cantor, J. R., & Lee, K. H. (2005) · PROTEOMICS · doi:10.1002/pmic.200401268 · Cited by 70
Structure of a lectin with antitumoral properties in king bolete (Boletus edulis) mushrooms
Bovi, M., Carrizo, M. E., Capaldi, S., Perduca, M., Chiarelli, L. R., Galliano, M., & Monaco, H. L. (2011) · Glycobiology · doi:10.1093/glycob/cwr012 · Cited by 66
Katayama, H., Tabata, T., Ishihama, Y., Sato, T., Oda, Y., & Nagasu, T. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1637 · Cited by 59
Luque-Garcia, J. L., Zhou, G., Sun, T., & Neubert, T. A. (2006) · Analytical Chemistry · doi:10.1021/ac060344t · Cited by 48
Nomura, E., Katsuta, K., Ueda, T., Toriyama, M., Mori, T., & Inagaki, N. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.578 · Cited by 46
McNamara, M. J., Tzeng, S., Maier, C. S., Zhang, L., & Bermudez, L. E. (2012) · Infection and Immunity · doi:10.1128/iai.06151-11 · Cited by 45
Recovery of Gel-Separated Proteins for In-Solution Digestion and Mass Spectrometry
Jonsson, P. A., Aissouni, Y., Palmberg, C., Percipalle, P., Nordling, E., Daneholt, B., Jörnvall, H., & Bergman, T. (2001) · Analytical Chemistry · doi:10.1021/ac010486h · Cited by 39
Efficient In-Gel Proteolysis Accelerated by Infrared Radiation for Protein Identification
Bao, H., Liu, T., Chen, X., & Chen, G. (2008) · Journal of Proteome Research · doi:10.1021/pr800572e · Cited by 26
Research works printed but not linked: 2
- Speicher K. D., 2000, J. Biomol. Tech., 11, 74
- Srinivasan S., 2010, Invest. Ophthalmol. Vis. Sci., 51, 5200
Cited by
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Novel Strategies to Address the Challenges in Top-Down Proteomics
Melby, J. A., Roberts, D. S., Larson, E. J., Brown, K. A., Bayne, E. F., Jin, S., & Ge, Y. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00099 · Cited by 190
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
“Previously, acid-cleavable surfactants such as Rapigest [28], ProteaseMAX [29], and MScompatible degradable surfactant MaSDeS [30] were developed as MS-compatible surfactants to enable protein solubilization for digestion and MS-analysis.”
BackgroundKirmiz, M., Vierra, N. C., Palacio, S., & Trimmer, J. S. (2018) · Journal of Neuroscience · doi:10.1523/jneurosci.0893-18.2018 · Cited by 130
“Gel bands were prepared essentially as described previously (Saveliev et al., 2013).”
Method
Metadata
- Authors
- Saveliev, S. V., Woodroofe, C. C., Sabat, G., Adams, C. M., Klaubert, D., Wood, K., & Urh, M.
- Affiliations
- Promega (United States) (US)
- University of Wisconsin–Madison (US)
- Stanford University (US)
- Corresponding author
- Saveliev, Sergei V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-07
- Volume
- 85
- Issue
- 2
- Pages
- 907-914
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1970731237
- Cited by
- 62
- References
- 18
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 6 · 2022: 2 · 2021: 5 · 2020: 12 · 2019: 5 · 2018: 5 · 2017: 6 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 3
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Organic Chemistry › Chemical Synthesis and Analysis
- Keywords
- SDS-PAGE, peptide extraction, peptide recovery, protein identification, protein sequence coverage, stable isotope labeling, peptide quantification
- MeSH terms
- Gels, Proteins, Surface-Active Agents, Molecular Structure, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.