Integrated Capillary Zone Electrophoresis–Electrospray Ionization Tandem Mass Spectrometry System with an Immobilized Trypsin Microreactor for Online Digestion and Analysis of Picogram Amounts of RAW 264.7 Cell Lysate
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A capillary zone electrophoresis (CZE) electrospray ionization (ESI) tandem mass spectrometry (MS/MS) system was integrated with an immobilized trypsin microreactor. The system was evaluated and then applied for online digestion and analysis of picogram loadings of RAW 264.7 cell lysate. Protein samples were dissolved in a buffer containing 50% (v/v) acetonitrile (ACN), and then directly loaded into the capillary for digestion, followed by CZE separation and MS/MS identification. The organic solvent (50% (v/v) ACN) assisted the immobilized trypsin digestion and simplified the protein sample preparation protocol. Neither protein reduction nor alkylation steps were employed, which minimized sample loss and contamination. The integrated CZE-ESI-MS/MS system generated confident identification of bovine serum albumin (BSA) with 19% sequence coverage and 14 peptide identifications (IDs) when 20 fmol was loaded. When only 1 fmol of BSA was injected, one BSA peptide was consistently detected. For the analysis of a standard protein mixture, the integrated system produced efficient protein digestion and confident identification for proteins with different molecular weights and isoelectric points when a low-femtomole amount was loaded for each protein. We further applied the system for triplicate analysis of a RAW 264.7 cell lysate; 2 ± 1 and 7 ± 2 protein groups were confidently identified from only 300 pg and 3 ng loadings, respectively. The 300 pg sample loading corresponds to the protein content of three RAW 264.7 cells. In addition to high-sensitivity analysis, the integrated CZE-ESI-MS/MS system produces good reproducibility in terms of peptide and protein IDs, peptide migration time, and peptide intensity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geiger, T., Wehner, A., Schaab, C., Cox, J., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014050 · Cited by 797
Wiśniewski, J. R., Ostasiewicz, P., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr200019m · Cited by 290
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Li, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128
Self-citationZhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac303750g · Cited by 103
Self-citationCapillary electrophoresis with Orbitrap-Velos mass spectrometry detection
Wojcik, R., Li, Y., MacCoss, M. J., & Dovichi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.10.048 · Cited by 43
Self-citation
Cited by
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61
Quantitative Proteomics Using Ultralow Flow Capillary Electrophoresis–Mass Spectrometry
Faserl, K., Kremser, L., Müller, M., Teis, D., & Lindner, H. H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00312 · Cited by 57
Capillary zone electrophoresis for bottom‐up analysis of complex proteomes
Sun, L., Zhu, G., Yan, X., Zhang, Z., Wojcik, R., Champion, M. M., & Dovichi, N. J. (2016) · PROTEOMICS · doi:10.1002/pmic.201500339 · Cited by 41
Self-citationRecent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30
Metadata
- Authors
- Sun, L., Zhu, G., & Dovichi, N. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-04-04
- Volume
- 85
- Issue
- 8
- Pages
- 4187-4194
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2331314753
- Cited by
- 55
- References
- 6
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated Capillary Zone Electrophoresis–Electrospray Ionization Tandem Mass Spectrometry System with an Immobilized Trypsin Microreactor for Online Digestion and Analysis of Picogram Amounts of RAW 264.7 Cell Lysate. https://app.cochat.ai/papers/10.1021/ac400523x
- The paper
- Sun, L., Zhu, G., & Dovichi, N. J. (2013). Integrated Capillary Zone Electrophoresis–Electrospray Ionization Tandem Mass Spectrometry System with an Immobilized Trypsin Microreactor for Online Digestion and Analysis of Picogram Amounts of RAW 264.7 Cell Lysate. Analytical Chemistry. https://doi.org/10.1021/ac400523x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.