Native Top-Down Electrospray Ionization-Mass Spectrometry of 158 kDa Protein Complex by High-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) delivers high resolving power, mass measurement accuracy, and the capabilities for unambiguously sequencing by a top-down MS approach. Here, we report isotopic resolution of a 158 kDa protein complex, tetrameric aldolase with an average absolute deviation of 0.36 ppm and an average resolving power of ~520 000 at m/z 6033 for the 26+ charge state in magnitude mode. Phase correction further improves the resolving power and average absolute deviation by 1.3-fold. Furthermore, native top-down electron capture dissociation (ECD) enables the sequencing of 168 C-terminal amino acid (AA) residues out of 463 total AAs. Combining the data from top-down MS of native and denatured aldolase complexes, a total of 56% of the total backbone bonds were cleaved. The observation of complementary product ion pairs confirms the correctness of the sequence and also the accuracy of the mass fitting of the isotopic distribution of the aldolase tetramer. Top-down MS of the native protein provides complementary sequence information to top-down ECD and collisonally activated dissociation (CAD) MS of the denatured protein. Moreover, native top-down ECD of aldolase tetramer reveals that ECD fragmentation is not limited only to the flexible regions of protein complexes and that regions located on the surface topology are prone to ECD cleavage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
Ge, Y., Rybakova, I. N., Xu, Q., & Moss, R. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813369106 · Cited by 154
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules
Brodbelt, J. S., Morrison, L. J., & Santos, I. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00440 · Cited by 295
Li, H., Nguyen, H. H., Ogorzalek Loo, R. R., Campuzano, I. D. G., & Loo, J. A. (2018) · Nature Chemistry · doi:10.1038/nchem.2908 · Cited by 249
“…including ours have demonstrated that direct sequence information can be obtained from protein complexes in their native states using either ECD 25–27, 41 or the similar technique, electron transfer dissociation ( ETD) 42 , ECD of protein complexes gave no fragment Although the structural…”
Self-citationIon Activation Methods for Peptides and Proteins
Brodbelt, J. S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04563 · Cited by 248
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Mass Spectrometry of Protein Complexes: From Origins to Applications
Mehmood, S., Allison, T. M., & Robinson, C. V. (2015) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040214-121732 · Cited by 199
“This was used in a top-down electron-capture dissociation study for improved sequence coverage of protein assemblies (54, 55) and to map the location of a ligand-binding site (56, 57).”
MethodRoberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Self-citationLermyte, F., Tsybin, Y. O., O’Connor, P. B., & Loo, J. A. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02201-x · Cited by 132
Self-citationWongkongkathep, P., Han, J. Y., Choi, T. S., Yin, S., Kim, H. I., & Loo, J. A. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-2002-2 · Cited by 71
Self-citationStandard Proteoforms and Their Complexes for Native Mass Spectrometry
Schachner, L. F., Ives, A. N., McGee, J. P., Melani, R. D., Kafader, J. O., Compton, P. D., Patrie, S. M., & Kelleher, N. L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02191-w · Cited by 48
“For example, ion-mobility has been widely applied to study biomolecule conformations in the gas-phase [39–42], and novel instrument designs, including the infinity cell for ICR analyzers [43, 44] and the UHMR for the Orbitrap [45], have improved sensitivity and resolving power for high-mass biomolecules, even for prot…”
Mikhailov, V. A., Griffiths, R. L., & Cooper, H. J. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.09.011 · Cited by 41
“Q-TOF mass analysers have been the analysers of choice in native ESI, due to their high m/z range [2, 19]; however, more recently native MS has been successfully implemented on FT ICR and Orbitrap instruments [20, 21], which offer mass resolution”
MethodCrittenden, C. M., Novelli, E. T., Mehaffey, M. R., Xu, G. N., Giles, D. H., Fies, W. A., Dalby, K. N., Webb, L. J., & Brodbelt, J. S. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00066 · Cited by 24
Top-Down Analysis of Branched Proteins Using Mass Spectrometry
Chen, D., Gomes, F., Abeykoon, D., Lemma, B., Wang, Y., Fushman, D., & Fenselau, C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05234 · Cited by 14
Metadata
- Authors
- Li, H., Wolff, J. J., Van Orden, S. L., & Loo, J. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-10
- Volume
- 86
- Issue
- 1
- Pages
- 317-320
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2312841378
- Cited by
- 118
- References
- 3
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.