CoChat

Biological and Technical Variables Affecting Immunoassay Recovery of Cytokines from Human Serum and Simulated Vaginal Fluid: A Multicenter Study

Open access
Fichorova, Raina N., Richardson-Harman, Nicola, Alfano, Massimo, Belec, Laurent, Carbonneil, Cedric, Chen, Silvia, Cosentino, Lisa, Curtis, Kelly, Dezzutti, Charlene S., Donoval, Betty, Doncel, Gustavo F., Donaghay, Melissa, Grivel, Jean-Charles, Guzman, Esmeralda, Hayes, Madeleine, Herold, Betsy, Hillier, Sharon, Lackman-Smith, Carol, Landay, Alan, Margolis, Leonid, Mayer, Kenneth H., Pasicznyk, Jenna-Malia, Pallansch-Cokonis, Melanie, Poli, Guido, Reichelderfer, Patricia, Roberts, Paula, Rodriguez, Irma, Saidi, Hela, Sassi, Rosaria Rita, Shattock, Robin, Cummins, Jr., James E. · 2008 · Analytical Chemistry
Cited by 184

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

The increase of proinflammatory cytokines in vaginal secretions may serve as a surrogate marker of unwanted inflammatory reaction to microbicide products topically applied for the prevention of sexually transmitted diseases, including HIV-1. Interleukin (IL)-1beta and IL-6 have been proposed as indicators of inflammation and increased risk of HIV-1 transmission; however, the lack of information regarding detection platforms optimal for vaginal fluids and interlaboratory variation limit their use for microbicide evaluation and other clinical applications. This study examines fluid matrix variants relevant to vaginal sampling techniques and proposes a model for interlaboratory comparisons across current cytokine detection technologies. IL-1beta and IL-6 standards were measured by 12 laboratories in four countries, using 14 immunoassays and four detection platforms based on absorbance, chemiluminescence, electrochemiluminescence, and fluorescence. International reference preparations of cytokines with defined biological activity were spiked into (1) a defined medium simulating the composition of human vaginal fluid at pH 4.5 and 7.2, (2) physiologic salt solutions (phosphate-buffered saline and saline) commonly used for vaginal lavage sampling in clinical studies of cytokines, and (3) human blood serum. Assays were assessed for reproducibility, linearity, accuracy, and significantly detectable fold difference in cytokine level. Factors with significant impact on cytokine recovery were determined by Kruskal-Wallis analysis of variance with Dunn's multiple comparison test and multiple regression models. All assays showed acceptable intra-assay reproducibility; however, most were associated with significant interlaboratory variation. The smallest reliably detectable cytokine differences ( P < 0.05) derived from pooled interlaboratory data varied from 1.5- to 26-fold depending on assay, cytokine, and matrix type. IL-6 but not IL-1beta determinations were lower in both saline and phosphate-buffered saline as compared to vaginal fluid matrix, with no significant effect of pH. The (electro)chemiluminescence-based assays were most discriminative and consistently detected <2-fold differences within each matrix type. The Luminex-based assays were less discriminative with lower reproducibility between laboratories. These results suggest the need for uniform vaginal sampling techniques and a better understanding of immunoassay platform differences and cross-validation before the biological significance of cytokine variations can be validated in clinical trials. This investigation provides the first standardized analytic approach for assessing differences in mucosal cytokine levels and may improve strategies for monitoring immune responses at the vaginal mucosal interface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac702628q

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 184

Metadata

Authors
Fichorova, R. N., Richardson-Harman, N., Alfano, M., Belec, L., Carbonneil, C., Chen, S., Cosentino, L., Curtis, K., Dezzutti, C. S., Donoval, B., Doncel, G. F., Donaghay, M., Grivel, J.-C., Guzman, E., Hayes, M., Herold, B., Hillier, S., Lackman-Smith, C., Landay, A., Margolis, L., Mayer, K. H., Pasicznyk, J.-M., Pallansch-Cokonis, M., Poli, G., Reichelderfer, P., Roberts, P., Rodriguez, I., Saidi, H., Sassi, R. R., Shattock, R., & Cummins, Jr.
Venue
Analytical Chemistry
Published
2008-05-17
Volume
80
Issue
12
Pages
4741-4751
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2048270654
Cited by
184
References
22
FWCI
9.05
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biological and Technical Variables Affecting Immunoassay Recovery of Cytokines from Human Serum and Simulated Vaginal Fluid: A Multicenter Study. https://app.cochat.ai/papers/10.1021/ac702628q
The paper
Fichorova, R. N., Richardson-Harman, N., Alfano, M., Belec, L., Carbonneil, C., Chen, S., Cosentino, L., Curtis, K., Dezzutti, C. S., Donoval, B., Doncel, G. F., Donaghay, M., Grivel, J.-C., Guzman, E., Hayes, M., Herold, B., Hillier, S., Lackman-Smith, C., Landay, A., . . . Cummins, Jr. (2008). Biological and Technical Variables Affecting Immunoassay Recovery of Cytokines from Human Serum and Simulated Vaginal Fluid: A Multicenter Study. Analytical Chemistry. https://doi.org/10.1021/ac702628q

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.