The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
Abstract
We describe the design and current performance of a 14.5 T hybrid linear quadrupole ion trap Fourier transform ion cyclotron resonance mass spectrometer. Ion masses are routinely determined at 4-fold better mass accuracy and 2-fold higher resolving power than similar 7 T systems at the same scan rate. The combination of high magnetic field and strict control of the number of trapped ions results in external calibration broadband mass accuracy typically less than 300 ppb rms, and a resolving power of 200,000 (m/Delta m50% at m/z 400) is achieved at greater than 1 mass spectrum per second. Novel ion storage optics and methodology increase the maximum number of ions that can be delivered to the FTICR cell, thereby improving dynamic range for tandem mass spectrometry and complex mixture applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Key interactions in HIV-1 maturation identified by hydrogen-deuterium exchange
Lanman, J., Lam, T. T., Emmett, M. R., Marshall, A. G., Sakalian, M., & Prevelige, P. E. (2004) · Nature Structural & Molecular Biology · doi:10.1038/nsmb790 · Cited by 164
Self-citation
Cited by
Petroleomics: Chemistry of the underworld
Marshall, A. G., & Rodgers, R. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805069105 · Cited by 673
Self-citationZubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Lu, W., Clasquin, M. F., Melamud, E., Amador-Noguez, D., Caudy, A. A., & Rabinowitz, J. D. (2010) · Analytical Chemistry · doi:10.1021/ac902837x · Cited by 502
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“5 T version of the LTQ-FT-ICR instrument has also been reported, featuring approximately 4-fold higher mass accuracy and twice the resolving power of the 7T instrument [99].”
MethodPrecision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
Gajiwala, K. S., Wu, J. C., Christensen, J., Deshmukh, G. D., Diehl, W., DiNitto, J. P., English, J. M., Greig, M. J., He, Y.-A., Jacques, S. L., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0812413106 · Cited by 391
Self-citationHendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citationIon dynamics in a trapped ion mobility spectrometer
Hernandez, D. R., DeBord, J. D., Ridgeway, M. E., Kaplan, D. A., Park, M. A., & Fernandez-Lima, F. (2014) · The Analyst · doi:10.1039/c3an02174b · Cited by 267
Performance evaluation of a high-field Orbitrap mass analyzer
Makarov, A., Denisov, E., & Lange, O. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.01.005 · Cited by 188
Measurement of Individual Ions Sharply Increases the Resolution of Orbitrap Mass Spectra of Proteins
Kafader, J. O., Melani, R. D., Senko, M. W., Makarov, A. A., Kelleher, N. L., & Compton, P. D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04519 · Cited by 87
Self-citationAnderson, L. C., DeHart, C. J., Kaiser, N. K., Fellers, R. T., Smith, D. F., Greer, J. B., LeDuc, R. D., Blakney, G. T., Thomas, P. M., Kelleher, N. L., et al. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00696 · Cited by 94
Self-citationValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Self-citation
Metadata
- Authors
- Schaub, T. M., Hendrickson, C. L., Horning, S., Quinn, J. P., Senko, M. W., & Marshall, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-05-09
- Volume
- 80
- Issue
- 11
- Pages
- 3985-3990
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000858971
- Cited by
- 192
- References
- 1
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.