Ionic Liquids Containing the Tris(pentafluoroethyl)trifluorophosphate Anion: a New Class of Highly Selective and Ultra Hydrophobic Solvents for the Extraction of Polycyclic Aromatic Hydrocarbons Using Single Drop Microextraction
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
A new class of ionic liquids (ILs) containing the tris(pentafluoroethyl)trifluorophosphate (FAP) anion are paired with imidazolium, phosphonium, and pyrrolidinium cations and used as extraction solvents in direct immersion single drop microextraction (SDME) studies coupled to high performance liquid chromatography (HPLC). The selectivity and sensitivity of the extraction method can be tuned and manipulated by varying the cationic component of the IL, thereby providing larger enrichment factors for a variety of analytes, including polycyclic aromatic hydrocarbons (PAHs). Compared to other hydrophobic ILs containing the hexafluorophosphate (PF(6)(-)) and bis[(trifluoromethyl)sulfonyl]imide (NTf(2)(-)) anions, FAP-based ILs are significantly more hydrophobic and hydrolytically stable permitting them to be used in the sampling of large volumes of aqueous solutions without dissolution or loss of the IL. The highest enrichment factors were obtained with the trihexyl(tetradecyl)phosphonium FAP ([PH(3)T] [FAP]) IL for compounds with high molecular weight and fused rings while high enrichment factors were obtained for smaller, more polar molecules using the 1-hexyl-3-methylimidazolium FAP ([HMIM] [FAP]) IL. The detection limits for nine studied PAHs ranged from 0.1 to 0.6, 0.03 to 0.4, 0.04 to 0.7 and 0.1 to 1.2 microg L(-1) for [HMIM] [FAP], [PH(3)T] [FAP], 1-butyl-1-methylpyrrolidinium FAP ([BMPL] [FAP]), and 1-(6-amino-hexyl)-1-methylpyrrolidinium FAP ([HNH(2)MPL] [FAP]), respectively. The reproducibility of the extraction method at 20 degrees C using the FAP-based ILs was in the range of 1.5-9.4%. Three real water samples including tap water, creek water, and river water were analyzed and yielded recoveries ranging from 79-114%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This study demonstrated that the application of SDME for analysis of PAHs had high efficiency [77].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [77]
Citations
Cites
CO2 Capture by a Task-Specific Ionic Liquid
Bates, E. D., Mayton, R. D., Ntai, I., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017593d · Cited by 2,270
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Ionic liquids are not always green: hydrolysis of 1-butyl-3-methylimidazolium hexafluorophosphate
Swatloski, R. P., Holbrey, J. D., & Rogers, R. D. (2003) · Green Chemistry · doi:10.1039/b304400a · Cited by 982
Electrodeposition from Ionic Liquids
(2008) · Wiley eBooks · doi:10.1002/9783527622917 · Cited by 804
Improving Carbon Dioxide Solubility in Ionic Liquids
Muldoon, M. J., Aki, S. N. V. K., Anderson, J. L., Dixon, J. K., & Brennecke, J. F. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp071897q · Cited by 800
Self-citationHe, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids
O’Mahony, A. M., Silvester, D. S., Aldous, L., Hardacre, C., & Compton, R. G. (2008) · Journal of Chemical & Engineering Data · doi:10.1021/je800678e · Cited by 574
Use of Ionic Liquids for Liquid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons
Liu, J.-F., Jiang, G.-B., Chi, Y.-G., Cai, Y.-Q., Zhou, Q.-X., & Hu, J.-T. (2003) · Analytical Chemistry · doi:10.1021/ac034506m · Cited by 484
Research works printed but not linked: 4
- Chrobok A., 2007, Pol. J. Chem., 81, 337
- Gammon M. D., 2002, Cancer Epidemiol. Biomarkers Prev., 11, 677
- Li D., 1996, Cancer Res., 56, 287
- Froehlich, U.Chirality and Ionic Liquids, PhD. dissertation, Queen’s University of Belfast, May 2005.
Cited by
Items 101–170 of 170
Investigation of tertiary amine-based PILs for ideal efficient SO2 capture from CO2
Geng, Z., Xie, Q., Fan, Z., Sun, W., Zhao, W., Zhang, J., Chen, J., & Xu, Y. (2021) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2021.105824 · Cited by 23
Havlíková, M., Čabala, R., Pacáková, V., Bursová, M., & Bosáková, Z. (2018) · Journal of Separation Science · doi:10.1002/jssc.201800902 · Cited by 22
Shamshina, J. L., & Bertón, P. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24097866 · Cited by 21
Das, S. K., & Sarkar, M. (2011) · Journal of Luminescence · doi:10.1016/j.jlumin.2011.09.002 · Cited by 21
Domańska, U., Lukoshko, E. V., & Królikowski, M. (2013) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2013.01.027 · Cited by 21
Das, S. K., Majhi, D., Sahu, P. K., & Sarkar, M. (2016) · ChemPhysChem · doi:10.1002/cphc.201600983 · Cited by 21
Zhu, J., Wang, Q., Li, M., Ren, L., Zheng, B., & Zou, X. (2017) · Analytical Methods · doi:10.1039/c6ay03189g · Cited by 22
Adhami, K., Asadollahzadeh, H., & Ghazizadeh, M. (2019) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2019.03.048 · Cited by 22
Jordan‐Sinisterra, M., Medina, D. A. V., & Lanças, F. M. (2022) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2022.104832 · Cited by 20
Applications of ionic liquids in the microextraction of pesticides: A mini-review
Boamah, P. O., Wang, L., Shen, W., Tang, S. N., & Lee, H. K. (2023) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2023.100090 · Cited by 21
Arshad, M. S., Kovač, J., Cruz, S. M. A., & Kalin, M. (2020) · Tribology International · doi:10.1016/j.triboint.2020.106482 · Cited by 20
de Castro, C. A. N., Ribeiro, A. P. C., Figueiras, A. O., Langa, E., Vieira, S. I. C., Lourenço, M. J., Santos, Â. F. S., Santos, F. J. V., Lampreia, I. M. S., Goodrich, P. A., et al. (2021) · Journal of Chemical & Engineering Data · doi:10.1021/acs.jced.0c01017 · Cited by 18
Zhou, X., Zhu, A., & Shi, G. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.07.040 · Cited by 18
Órfão, E. F., Dohnal, V., & Blahut, A. (2013) · The Journal of Chemical Thermodynamics · doi:10.1016/j.jct.2013.05.035 · Cited by 18
Mao, J. X., & Damodaran, K. (2014) · Ionics · doi:10.1007/s11581-014-1341-7 · Cited by 17
Zhao, Q., & Anderson, J. L. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00053-3 · Cited by 19
Self-citationPadró, J. M., Vidal, R. B. P., & Reta, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8264-z · Cited by 17
“The use of PB-RTILs in liquid-liquid extractions has been scarcely reported in the literature [9, 10].”
BackgroundInfluentialPolycyclic aromatic hydrocarbons as model solutes for carbon nanomaterials in ionic liquids
Bordes, É., Costa, A. J. L., Szala‐Bilnik, J., Andanson, J., Esperança, J. M. S. S., Gomes, M. C., Lopes, J. N. C., & Pádua, A. A. H. (2017) · Physical Chemistry Chemical Physics · doi:10.1039/c7cp04932c · Cited by 15
Toots, K. M., Sild, S., Leis, J., Acree, W. E., & Maran, U. (2021) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2021.117573 · Cited by 15
Analytical Applications of Ionic Liquids
Acree, W. E., & Grubbs, L. M. (2012) · Wiley eBooks · doi:10.1002/9780470027318.a9153 · Cited by 14
Costa, R., Pereira, C. M. D. M., & Silva, F. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.01.232 · Cited by 13
Stephens, N. M., Masching, H. P., Walid, M. K. I., Petrich, J. W., Anderson, J. L., & Smith, E. A. (2022) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.2c01588 · Cited by 13
Self-citationIonic liquids in separation and preconcentration of organic and inorganic species
Khezeli, T., Ghaedi, M., Daneshfar, A., Bahrani, S., Asfaram, A., & Soylak, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818569-8.00006-1 · Cited by 13
Dołżonek, J., Synak, E., Fabiańska, A., Caban, M., Stolte, S., Husson, P., Gomes, M. C., Synak, R., & Stepnowski, P. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8545-1 · Cited by 11
Rauber, D., Philippi, F., & Hempelmann, R. (2017) · Journal of Fluorine Chemistry · doi:10.1016/j.jfluchem.2017.06.014 · Cited by 11
Ionic Mobility within Functionalized Silica Nanopores
Elola, M. D., & Rodríguez, J. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.8b11444 · Cited by 11
Das, S. K., Sahu, P. K., & Sarkar, M. (2014) · RSC Advances · doi:10.1039/c4ra05582a · Cited by 11
5 Choice of Solvent in Liquid-Phase Microextraction
Dadfarnia, S., & Haji-Shabani, A. M. (2014) · doi:10.2478/9783110410181.5 · Cited by 14
Hawkins, C. A., Rud, A., Garvey, S. L., & Dietz, M. L. (2012) · Separation Science and Technology · doi:10.1080/01496395.2012.697527 · Cited by 11
“1-(10-hydroxydecyl)-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide (9) From compound 3 (7.”
Jumepaeng, T., Luthria, D. L., & Chanthai, S. (2011) · Analytical Methods · doi:10.1039/c2ay05646a · Cited by 10
Off-line sample preparation by electrophoretic concentration using a micropipette and hydrogel
Wuethrich, A., Haddad, P. R., & Quirino, J. P. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.006 · Cited by 10
“[5] C.”
Fotouhi, L., Seidi, S., & Shahsavari, F. (2016) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-016-0843-9 · Cited by 10
Structure and Dynamics of Nonionic Surfactants Adsorbed at Vacuum/Ionic Liquid Interfaces
Elola, M. D., & Rodríguez, J. (2013) · Langmuir · doi:10.1021/la402683j · Cited by 10
Pliquett, D., Schulz, P. S., Heinemann, F. W., Bause, A., & Wasserscheid, P. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp05653a · Cited by 10
Rauber, D., Heib, F., Dier, T. K. F., Volmer, D. A., Hempelmann, R., & Schmitt, M. (2017) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2017.05.092 · Cited by 10
Exploring the corrosion inhibition capability of FAP-based ionic liquids on stainless steel
Tiongson, J. K. A., Aganda, K. C. C., Bruzon, D. A. V., Guevara, A. P., Basilia, B. A., Tapang, G. A., & Martinez, I. S. (2020) · Royal Society Open Science · doi:10.1098/rsos.200580 · Cited by 10
Theoretical selection of most effective ionic liquids for liquid–liquid extraction of NdF3
Grabda, M., Oleszek, S., Panigrahi, M., Kozak, D. S., Eckert, F., Shibata, E., & Nakamura, T. (2015) · Computational and Theoretical Chemistry · doi:10.1016/j.comptc.2015.03.016 · Cited by 10
Chen, X., Xin, L., Xu, Y., Liu, J., Li, Z., Wang, Y., & Zhao, J. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900410 · Cited by 9
Xiao, J., Cheng, J., Guo, F., Hu, H.-L., Peng, S., Zhang, M., & Cheng, M. (2012) · Microchimica Acta · doi:10.1007/s00604-012-0806-5 · Cited by 10
“The microdrop volume is typically limited by the stability of the microdrop, which is a function of the viscosity and surface tension of the extraction solvent [19].”
Background1-Aryl-3,5-dimethylpyrazolium based tunable protic ionic liquids (TPILs)
Özdemir, M. C., Özgün, B., & Aktan, E. (2018) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2018.12.027 · Cited by 9
Characterization and Functionality of Immidazolium Ionic Liquids Modified Magnetic Nanoparticles
Li, Y., Tang, N., Inagaki, F., Mukai, C., & Hayakawa, K. (2013) · Journal of Chemistry · doi:10.1155/2013/861021 · Cited by 8
Selection of Ionic Liquid Solvents for Chemical Separations Based on the Abraham Model
William, E., Jr., Laura, M., & Michael, H. (2011) · InTech eBooks · doi:10.5772/14518 · Cited by 14
Ebrahimi, S., & Kowsari, M. H. (2019) · Physical Chemistry Chemical Physics · doi:10.1039/c8cp07829g · Cited by 8
Wang, N., Zhang, Y., & Maginn, E. J. (2022) · Journal of Ionic Liquids · doi:10.1016/j.jil.2022.100040 · Cited by 8
Sun, Z., Zheng, L., Zhang, Z.-Y., Cong, Y., Yang, J., & Wang, X. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121599 · Cited by 7
Tiongson, J. K. A., Bruzon, D. A. V., Tapang, G. A., & Martinez, I. S. (2018) · Journal of Chemical & Engineering Data · doi:10.1021/acs.jced.7b00281 · Cited by 7
Use of Unconventional Solvents for Sample Preparation in Environmental Analysis
Meng, Y., & Anderson, J. L. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00123-x · Cited by 9
Self-citationGreening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Liquid-Phase Extraction and Microextraction
Fernández, E., & Vidal, L. (2014) · Elsevier eBooks · doi:10.1016/b978-0-444-63257-9.00003-1 · Cited by 7
Ionic Liquids and Polymeric Ionic Liquids in Analytical Environmental Applications
Yu, H., Zhang, C., & Anderson, J. L. (2015) · Springer eBooks · doi:10.1007/978-3-662-44903-5_7 · Cited by 6
“The [PH3T][FAP] IL exhibited the most desirable hydrophobicity, selectivity, and viscosity which contributed to the formation of a stable microdroplet and resulted in the highest enrichment factors for most analytes [30].”
BackgroundSelf-citationLiu, X., Liu, K., Yao, C., Deng, D., & Tian, C. (2025) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2025.127634 · Cited by 4
Self-citationExtraction Procedures for Organic Pollutants Determination in Water
Etxebarría, N., Navarro, P., Prieto, A., Olivares, M., Usobiaga, A., Fernández, L. A., & Zuloaga, O. (2011) · Environmental chemistry for a sustainable world · doi:10.1007/978-94-007-2439-6_4 · Cited by 6
Ionic liquid-based liquid-phase microextraction techniques
Azorín, C., Benedé, J. L., & Chisvert, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823334-4.00006-0 · Cited by 4
Green sample preparation techniques in environmental analysis
Casado-Carmona, F. A., Lasarte‐Aragonés, G., Lucena, R., & Cárdenas, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822234-8.00002-0 · Cited by 7
Probing the Interface of Charged Surfactants in Ionic Liquids by XPS
Chen, L. G., & Bermudez, H. (2012) · ACS symposium series · doi:10.1021/bk-2012-1117.ch014 · Cited by 2
Abiotic Degradation of Ionic Liquids (ILs)
Samorì, C., & Pirini, D. (2019) · Encyclopedia of Ionic Liquids · doi:10.1007/978-981-10-6739-6_57-1 · Cited by 2
Aggregation and Interfacial Behavior of Charged Surfactants in Ionic Liquids
Chen, L. (2015) · ScholarWorks@UMassAmherst (University of Massachusetts Amherst) · doi:10.7275/6160910.0 · Cited by 2
8 Green Aspects of Miniaturized Sample Preparation Techniques
Kloskowski, A., Marcinkowski, Ł., & Namieśnik, J. (2014) · doi:10.2478/9783110410181.8 · Cited by 4
“The increased amount of sorption phase allowed the application of IL-coated fibers for isolating polycyclic aromatic hydrocarbons (PAHs) from aqueous samples.”
InfluentialIonic Liquids in Green Sample Preparation
Mastellone, G., Marengo, A., Sgorbini, B., Rubiolo, P., & Cagliero, C. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839166419-00179 · Cited by 1
Abiotic Degradation of Ionic Liquids (ILs)
Samorì, C., & Pirini, D. (2022) · Encyclopedia of Ionic Liquids · doi:10.1007/978-981-33-4221-7_57 · Cited by 1
Microextraction Technique for Determination of Aromatic Pollutant in Environmental Samples
Galán‐Cano, F., Lucena, R., & Cárdenas, S. (2012) · Wiley eBooks · doi:10.1002/9780470027318.a9239
Smith, R. E., Tran, K., Sack, C. A., & Richards, K. M. (2015) · doi:10.1201/9780429099359-6
Smith, R., Tran, K., Sack, C. A., & Richards, K. M. (2015) · Chromatographic science/Chromatographic science series · doi:10.1201/b18481-7
Power loss of FZG gears lubricated with wind turbine gear oil using ionic liquid additive
Fernandes, C. M. C. G., Antolín, H. B., Ruben, G. R., Monge, R., Viesca, J. L., Alberto, G., Martins Ramiro, C., & Seabra, J. (2024) · Iberian Conference on Tribology (IBERTRIB) · doi:10.31428/10317/10674
“A new type of ILs using the FAP anion (manufactured by Merck KGaA [27]) shows a better hydrolytic stability.”
MethodExtraction of Bio-based Organic Acids using Supported Liquid Membranes with Novel Solvents
López‐Porfiri, P. (2022) · DIGITAL.CSIC (Spanish National Research Council (CSIC))
Captage du dioxyde de carbone par des liquides ioniques partiellement fluorés
Almantariotis, D. (2011) · theses.fr (ABES) · doi:10.70675/eead6bf3zabebz498az8c1bz641298fc8aae · Cited by 1
Graphène dans des liquides ioniques : interactions aux interfaces, exfoliation, stabilisation
Bordes, É. (2017) · theses.fr (ABES) · doi:10.70675/b729dc87z8cb9z4809zb508z630180402ec1 · Cited by 1
Gonzálvez, M. A., Wang, X., Bond, A. M., & Zhang, J. (2026) · ACS electrochemistry. · doi:10.1021/acselectrochem.6c00093
Metadata
- Authors
- Yao, C., Pitner, W. R., & Anderson, J. L.
- Affiliations
- University of Toledo (US)
- Corresponding author
- Anderson, Jared L.
- ORCID
- Anderson, Jared L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-05-06
- Volume
- 81
- Issue
- 12
- Pages
- 5054-5063
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2040862406
- Cited by
- 167
- References
- 30
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 4 · 2022: 6 · 2021: 6 · 2020: 12 · 2019: 9 · 2018: 5 · 2017: 7 · 2016: 8 · 2015: 20 · 2014: 15 · 2013: 11 · 2012: 24
- FWCI
- 19.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- ionic liquids, polycyclic aromatic hydrocarbons, single-drop microextraction, hydrophobic solvents, extraction selectivity, enrichment factor, cation effects, phosphonium ionic liquids, imidazolium ionic liquids, pyrrolidinium ionic liquids, water sample analysis, hydrolytic stability, tap water
- MeSH terms
- Chromatography, High Pressure Liquid, Fluorocarbons, Hydrocarbons, Fluorinated, Polycyclic Aromatic Hydrocarbons, Solvents, Spectrometry, Fluorescence, Time Factors, Reproducibility of Results, Sample Size, Ionic Liquids, Hydrophobic and Hydrophilic Interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.