The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Precursor Acquisition Independent From Ion Count: How to Dive Deeper into the Proteomics Ocean
Open accessAbstract
Data-dependent precursor ion selection is widely used in shotgun proteomics to profile the protein components of complex samples. Although very popular, this bottom-up method presents major drawbacks in terms of detectable dynamic range. Here, we demonstrate the superior performance of a data-independent method we term precursor acquisition independent from ion count (PAcIFIC). Our results show that almost the entire, predicted, soluble bacterial proteome can be thoroughly analyzed by PAcIFIC without the need for any sample fractionation other than the C18-based liquid chromatograph used to introduce the peptide mixture into the mass spectrometer. Importantly, we also show that PAcIFIC provides unique performance for analysis of human plasma in terms of the number of proteins identified (746 at FDR < or = 0.5%) and achieved dynamic range (8 orders of magnitude at FDR < or = 0.5%), without any fractionation other than immuno-depletion of the seven most abundant proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Cited by
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Comet: An open‐source MS / MS sequence database search tool
Eng, J. K., Jahan, T. A., & Hoopmann, M. R. (2013) · PROTEOMICS · doi:10.1002/pmic.201200439 · Cited by 1,474
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Data‐independent acquisition‐based SWATH ‐ MS for quantitative proteomics: a tutorial
Ludwig, C., Gillet, L., Rosenberger, G., Amon, S., Collins, B. C., & Aebersold, R. (2018) · Molecular Systems Biology · doi:10.15252/msb.20178126 · Cited by 1,002
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
OpenSWATH enables automated, targeted analysis of data-independent acquisition MS data
Röst, H. L., Rosenberger, G., Navarro, P., Gillet, L., Miladinović, S. M., Schubert, O. T., Wolski, W., Collins, B. C., Malmström, J., Malmström, L., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.2841 · Cited by 765
Less label, more free: Approaches in label‐free quantitative mass spectrometry
Neilson, K. A., Ali, N. A., Muralidharan, S., Mirzaei, M., Mariani, M., Assadourian, G., Lee, A., van Sluyter, S. C., & Haynes, P. A. (2011) · PROTEOMICS · doi:10.1002/pmic.201000553 · Cited by 704
DIA-Umpire: comprehensive computational framework for data-independent acquisition proteomics
Tsou, C.-C., Avtonomov, D., Larsen, B., Tucholska, M., Choi, H., Gingras, A.-C., & Nesvizhskii, A. I. (2015) · Nature Methods · doi:10.1038/nmeth.3255 · Cited by 644
Collins, B. C., Hunter, C. L., Liu, Y., Schilling, B., Rosenberger, G., Bader, S. L., Chan, D. W., Gibson, B. W., Gingras, A.-C., Held, J. M., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00249-5 · Cited by 576
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Searle, B. C., Pino, L. K., Egertson, J. D., Ting, Y. S., Lawrence, R. T., MacLean, B. X., Villén, J., & MacCoss, M. J. (2018) · Nature Communications · doi:10.1038/s41467-018-07454-w · Cited by 522
Mass Spectrometry–Based Proteomics and Network Biology
Bensimon, A., Heck, A. J. R., & Aebersold, R. (2012) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-072909-100424 · Cited by 410
Vidova, V., & Spacil, Z. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.059 · Cited by 352
Gillet, L. C., Leitner, A., & Aebersold, R. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041535 · Cited by 323
Bräsen, C., Esser, D., Rauch, B., & Siebers, B. (2014) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00041-13 · Cited by 321
Collins, B. C., Gillet, L. C., Rosenberger, G., Röst, H. L., Vichalkovski, A., Gstaiger, M., & Aebersold, R. (2013) · Nature Methods · doi:10.1038/nmeth.2703 · Cited by 314
Multiplexed MS/MS for improved data-independent acquisition
Egertson, J. D., Kuehn, A., Merrihew, G. E., Bateman, N. W., MacLean, B. X., Ting, Y. S., Canterbury, J. D., Marsh, D. M., Kellmann, M., Zabrouskov, V., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2528 · Cited by 304
Pino, L. K., Just, S. C., MacCoss, M. J., & Searle, B. C. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.p119.001913 · Cited by 284
Multiplexed and data‐independent tandem mass spectrometry for global proteome profiling
Chapman, J. D., Goodlett, D. R., & Masselon, C. D. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21400 · Cited by 259
Self-citationAdvances in targeted proteomics and applications to biomedical research
Shi, T., Song, E., Nie, S., Rodland, K. D., Liu, T., Qian, W., & Smith, R. D. (2016) · PROTEOMICS · doi:10.1002/pmic.201500449 · Cited by 257
Generating high quality libraries for DIA MS with empirically corrected peptide predictions
Searle, B. C., Swearingen, K. E., Barnes, C. A., Schmidt, T., Gessulat, S., Küster, B., & Wilhelm, M. (2020) · Nature Communications · doi:10.1038/s41467-020-15346-1 · Cited by 255
Ting, Y. S., Egertson, J. D., Payne, S. H., Kim, S., MacLean, B., Käll, L., Aebersold, R., Smith, R. D., Noble, W. S., & MacCoss, M. J. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.047035 · Cited by 175
Meyer, J. G., & Schilling, B. (2017) · Expert Review of Proteomics · doi:10.1080/14789450.2017.1322904 · Cited by 151
Pacheco, N. L., Heaven, M. R., Holt, L. M., Crossman, D. K., Boggio, K. J., Shaffer, S. A., Flint, D. L., & Olsen, M. L. (2017) · Molecular Autism · doi:10.1186/s13229-017-0174-4 · Cited by 90
Self-citationSalovska, B., Li, W., Di, Y., & Liu, Y. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04293 · Cited by 35
Metadata
- Authors
- Panchaud, A., Scherl, A., Shaffer, S. A., von Haller, P. D., Kulasekara, H. D., Miller, S. I., & Goodlett, D. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-02
- Volume
- 81
- Issue
- 15
- Pages
- 6481-6488
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2014859022
- Cited by
- 262
- References
- 3
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.