The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid, Direct Analysis of Cholesterol by Charge Labeling in Reactive Desorption Electrospray Ionization
Open accessAbstract
Direct and rapid analysis of cholesterol was accomplished in the ambient environment using reactive desorption electrospray ionization (DESI) mass spectrometry. This was achieved by electrospraying reagent solutions in the form of high velocity charged droplets at surfaces such as dried serum samples and animal tissue sections. Betaine aldehyde, incorporated into the spray solvent, reacts selectively and rapidly with the alcohol group of cholesterol by nucleophilic addition, forming a hemiacetal salt. Limits of detection for pure cholesterol and related compounds were approximately 1 ng when a solution of cholesterol of 1 microg/mL was spotted onto the surface. Quantitative analysis of free cholesterol in serum using reactive DESI was demonstrated using cholesterol-d7 as internal standard. High throughput analysis of small volumes of serum spotted onto a suitable substrate was achieved at an analysis rate of approximately 14 s per sample, with a relative standard deviation (RSD) of ca. 6%. Use of reactive DESI in the imaging mode allowed 2D spatial distributions of phospholipids and cholesterol to be recorded simultaneously in rat brain tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrating spatially resolved three-dimensional MALDI IMS with in vivo magnetic resonance imaging
Sinha, T. K., Khatib-Shahidi, S., Yankeelov, T. E., Mapara, K., Ehtesham, M., Cornett, D. S., Dawant, B. M., Caprioli, R. M., & Gore, J. C. (2008) · Nature Methods · doi:10.1038/nmeth1147 · Cited by 168
Cited by
Development, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Self-citationAccelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
Self-citationMass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Self-citationTargeted Metabolomics for Biomarker Discovery
Griffiths, W. J., Koal, T., Wang, Y., Kohl, M., Enot, D. P., & Deigner, H. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905579 · Cited by 415
Ifa, D. R., Wu, C., Ouyang, Z., & Cooks, R. G. (2010) · The Analyst · doi:10.1039/b925257f · Cited by 384
Self-citationAdvances in Mass Spectrometry for Lipidomics
Blanksby, S. J., & Mitchell, T. W. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073705 · Cited by 366
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Sample preparation for mass spectrometry imaging: Small mistakes can lead to big consequences
Goodwin, R. J. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.012 · Cited by 313
Eberlin, L. S., Ferreira, C. R., Dill, A. L., Ifa, D. R., & Cooks, R. G. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.006 · Cited by 257
Self-citationGuo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Metadata
- Authors
- Wu, C., Ifa, D. R., Manicke, N. E., & Cooks, R. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-19
- Volume
- 81
- Issue
- 18
- Pages
- 7618-7624
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993399410
- Cited by
- 238
- References
- 1
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.