The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Reagentless Bidirectional Lateral Flow Bioactive Paper Sensors for Detection of Pesticides in Beverage and Food Samples
Abstract
A reagentless bioactive paper-based solid-phase biosensor was developed for detection of acetylcholinesterase (AChE) inhibitors, including organophosphate pesticides. The assay strip is composed of a paper support (1 x 10 cm), onto which AChE and a chromogenic substrate, indophenyl acetate (IPA), were entrapped using biocompatible sol-gel derived silica inks in two different zones (e.g., sensing and substrate zones). The assay protocol involves first introducing the sample to the sensing zone via lateral flow of a pesticide-containing solution. Following an incubation period, the opposite end of the paper support is placed into distilled deionized water (ddH(2)O) to allow lateral flow in the opposite direction to move paper-bound IPA to the sensing area to initiate enzyme catalyzed hydrolysis of the substrate, causing a yellow-to-blue color change. The modified sensor is able to detect pesticides without the use of any external reagents with excellent detection limits (bendiocarb approximately 1 nM; carbaryl approximately 10 nM; paraoxon approximately 1 nM; malathion approximately 10 nM) and rapid response times (approximately 5 min). The sensor strip showed negligible matrix effects in detection of pesticides in spiked milk and apple juice samples. Bioactive paper-based assays on pesticide residues collected from food samples showed good agreement with a conventional mass spectrometric assay method. The bioactive paper assay should, therefore, be suitable for rapid screening of trace levels of organophosphate and carbamate pesticides in environmental and food samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new and rapid colorimetric determination of acetylcholinesterase activity
Ellman, G. L., Courtney, K. D., Andres, V., & Featherstone, R. M. (1961) · Biochemical Pharmacology · doi:10.1016/0006-2952(61)90145-9 · Cited by 27,126
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Recent Advances in Paper-Based Sensors
Liana, D. D., Raguse, B., Gooding, J. J., & Chow, E. (2012) · Sensors · doi:10.3390/s120911505 · Cited by 660
Nanomaterials for Sensing and Destroying Pesticides
Aragay, G., Pino, F., & Merkoçi, A. (2012) · Chemical Reviews · doi:10.1021/cr300020c · Cited by 573
Recent developments and applications of screen-printed electrodes in environmental assays—A review
Li, M., Li, Y.-T., Li, D.-W., & Long, Y.-T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.018 · Cited by 550
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.037 · Cited by 434
Review of optical sensors for pesticides
Yan, X., Li, H., & Su, X. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.03.004 · Cited by 385
Ruecha, N., Rangkupan, R., Rodthongkum, N., & Chailapakul, O. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.018 · Cited by 342
Cellulose: from biocompatible to bioactive material
Credou, J., & Berthelot, T. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00431k · Cited by 335
Lv, S., Tang, Y., Zhang, K., & Tang, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04981 · Cited by 311
Li, J., Rossignol, F., & Macdonald, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00235d · Cited by 307
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Paper-Based Sensors: Emerging Themes and Applications
Singh, A. T., Lantigua, D., Meka, A., Taing, S., Pandher, M., & Camci-Unal, G. (2018) · Sensors · doi:10.3390/s18092838 · Cited by 284
Metadata
- Authors
- Hossain, S. M. Z., Luckham, R. E., McFadden, M. J., & Brennan, J. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-09-29
- Volume
- 81
- Issue
- 21
- Pages
- 9055-9064
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2031193156
- Cited by
- 316
- References
- 19
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.