Dispersive Liquid−Liquid Microextraction Coupled with Dispersive μ-Solid-Phase Extraction for the Fast Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples
Abstract
A new two-step microextraction technique, combining dispersive liquid-liquid microextraction (DLLME) and dispersive microsolid-phase extraction (D-micro-SPE), was developed for the fast gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons (PAHs) in environmental samples. A feature of the new procedure lies in that any organic solvent immiscible with water can be used as extractant in DLLME. A special apparatus, such as conical-bottom test tubes, and tedious procedures of centrifugation, refrigeration of the solvent, and then thawing it, associated with classical DLLME or similar techniques are not necessary in the new procedure, which potentially lends itself to possible automation. In the present D-micro-SPE approach, hydrophobic magnetic nanoparticles were used to retrieve the extractant of 1-octanol in the DLLME step. It is noteworthy that the target of D-micro-SPE was the 1-octanol rather than the PAHs. Because of the rapid mass transfer associated with the DLLME and the D-micro-SPE steps, fast extraction could be achieved. Parameters affecting the extraction efficiency were investigated in detail. The optimal conditions were as follows: vortex at 3200 rpm in the DLLME step for 2 min and in D-micro-SPE for 1 min and then desorption by sonication for 4 min with acetonitrile as the solvent. The results demonstrated that enrichment factors ranging from 110- to 186-fold were obtained for the analytes. The limits of detection and the limits of quantification were in the range of 11.7-61.4 pg/mL and 0.04-0.21 ng/mL, respectively. The linearities were 0.5-50, 1-50, or 2-50 ng/mL for different PAHs. Finally, the two-step extraction method was successfully used for the fast determination of PAHs in river water samples. This two-step method, combining two different and efficient miniaturized techniques, provides a fast means of sample pretreatment for environmental water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.094 · Cited by 248
Research works printed but not linked: 27
- Arthur C. L., 1990, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
- Dietz C., 2006, J. Chromatogr., A, 1103, 183, 10.1016/j.chroma.2005.11.041 · DOI · Paper page
- Svec F., 2006, J. Chromatogr., B, 841, 52, 10.1016/j.jchromb.2006.03.055 · doi:10.1016/j.jchromb.2006.03.055
- Zheng M. M., 2007, J. Chromatogr., A, 1164, 48, 10.1016/j.chroma.2007.07.020 · DOI
- Dietz C., 2006, J. Chromatogr., A, 1103, 183, 10.1016/j.chroma.2005.11.041 · DOI · Paper page
- Liu H. H., 1996, Anal. Chem., 68, 1817, 10.1021/ac960145h · DOI · Paper page
- He Y., 1997, Anal. Chem., 69, 4634, 10.1021/ac970242q · DOI · Paper page
- Kokosa J. M., 2003, J. Chromatogr., A, 983, 205, 10.1016/S0021-9673(02)01686-2 · DOI
- Pedersen-Bjergaard S., 1999, Anal. Chem., 71, 2650, 10.1021/ac990055n · DOI · Paper page
- Xu L., 2007, J. Chromatogr., A, 1152, 184, 10.1016/j.chroma.2006.10.073 · DOI · Paper page
- Lambropoulou D. A., 2007, J. Chromatogr., A, 1152, 70, 10.1016/j.chroma.2007.02.094 · DOI
- David F., 2007, J. Chromatogr., A, 1152, 54, 10.1016/j.chroma.2007.01.032 · DOI · Paper page
- Barri T., 2008, J. Chromatogr., A, 1186, 16, 10.1016/j.chroma.2008.02.002 · DOI
- Hylton K., 2007, J. Chromatogr., A, 1152, 199, 10.1016/j.chroma.2006.12.047 · DOI
- Basheer C., 2006, Anal. Chem., 78, 2853, 10.1021/ac060240i · DOI · Paper page
- García-López M., 2007, J. Chromatogr., A, 1166, 9, 10.1016/j.chroma.2007.08.006 · DOI
- Fariña L., 2007, J. Chromatogr., A, 1157, 46, 10.1016/j.chroma.2007.05.006 · DOI · Paper page
- Zang X., 2008, Anal. Bioanal. Chem., 392, 749, 10.1007/s00216-008-2296-1 · DOI · Paper page
- Rezaee M., 2009, J. Chromatogr., A, 1216, 1511, 10.1016/j.chroma.2008.12.091 · DOI · Paper page
- Cruz-Vera M., 2009, J. Chromatogr., A, 1216, 6459, 10.1016/j.chroma.2009.07.040 · DOI · Paper page
- Leong M. I., 2008, J. Chromatogr., A, 1211, 8, 10.1016/j.chroma.2008.09.111 · DOI · Paper page
- Farajzadeh M. A., 2009, J. Sep. Sci., 32, 3191, 10.1002/jssc.200900109 · DOI · Paper page
- Barker S. A., 1989, J. Chromatogr., 475, 353, 10.1016/S0021-9673(01)89689-8 · DOI · Paper page
- Barker S. A., 2007, J. Biochem. Biophys. Methods, 70, 151, 10.1016/j.jbbm.2006.06.005 · DOI · Paper page
- Deng H., 2005, Angew. Chem., Int. Ed., 44, 2782, 10.1002/anie.200462551 · DOI · Paper page
- Rianawati E., 2009, Phys. Chem. Earth, 34, 857, 10.1016/j.pce.2009.07.003 · DOI
- Xu L., 2009, J. Chromatogr., A, 1216, 5483, 10.1016/j.chroma.2009.05.074 · DOI
Cited by
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476
Recent advances in sample preparation techniques for effective bioanalytical methods
Kole, P. L., Venkatesh, G., Kotecha, J., & Sheshala, R. (2011) · Biomedical Chromatography · doi:10.1002/bmc.1560 · Cited by 366
Liquid-phase microextraction – The different principles and configurations
Yamini, Y., Rezazadeh, M., & Seidi, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.06.010 · Cited by 309
Luo, Y.-B., Shi, Z.-G., Gao, Q., & Feng, Y.-Q. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.01.022 · Cited by 261
Self-citationRecent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Metadata
- Authors
- Shi, Z.-G., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-21
- Volume
- 82
- Issue
- 4
- Pages
- 1540-1545
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2005770731
- Cited by
- 230
- References
- 6
- FWCI
- 24.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.