The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Conjugation of Glucose Oxidase onto Mn-Doped ZnS Quantum Dots for Phosphorescent Sensing of Glucose in Biological Fluids
Abstract
Integrating various enzymes with nanomaterials provides various nanohybrids with new possibilities in biosensor applications. Furthermore, the enzymatic activity and stability are also improved due to the large surface area of nanomaterials. Here we report the conjugation of glucose oxidase (GOD) onto phosphorescent Mn-doped ZnS quantum dots (QDs) using 1-ethyl-3-(3-dimethylaminopropy)carbodiimide (EDC)/N-hydroxysuccinimide (NHS) as coupling reagents for glucose biosensing based on the effective quenching of the room temperature phosphorescence (RTP) of Mn-doped ZnS QDs by the H(2)O(2) generated from GOD-catalyzed oxidation of glucose. The obtained bioconjugate not only provided improved enzymatic performance with Michaelis-Menten constant of 0.70 mM but also favored biological applications because the phosphorescent detection mode avoided the interference from autofluorescence and scattering light from the biological matrix. In addition, the GOD-conjugated Mn-doped ZnS QDs showed better thermal stability in the temperature range of 20-80 degrees C. The GOD-Mn-doped ZnS QDs based RTP sensor for glucose gave a detection limit of 3 microM and two linear ranges from 10 microM to 0.1 mM and from 0.1 to 1 mM. The developed biosensor was successfully applied to the determination of glucose in real serum samples without the need for any complicated sample pretreatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Semiconductor Quantum Dots for Bioanalysis
Gill, R., Zayats, M., & Willner, I. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800169 · Cited by 902
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Antigen/Antibody Immunocomplex from CdTe Nanoparticle Bioconjugates
Wang, S., Mamedova, N., Kotov, N. A., Chen, W., & Studer, J. (2002) · Nano Letters · doi:10.1021/nl0255193 · Cited by 529
The use of luminescent quantum dots for optical sensing
Costa-Fernández, J. M., Pereiro, R., & Sanz-Medel, A. (2006) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.07.008 · Cited by 527
Immobilizing Enzymes: How to Create More Suitable Biocatalysts
Bornscheuer, U. T. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200301664 · Cited by 518
Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition
Wei, A., Sun, X. W., Wang, J. X., Lei, Y., Cai, X. P., Li, C. M., Dong, Z. L., & Huang, W. (2006) · Applied Physics Letters · doi:10.1063/1.2356307 · Cited by 442
Cited by
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Zhou, J., Yang, Y., & Zhang, C.-Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00049 · Cited by 704
Doped quantum dots for chemo/biosensing and bioimaging
Wu, P., & Yan, X.-P. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60017c · Cited by 667
Self-citationShen, P., & Xia, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5001338 · Cited by 596
New Generation Cadmium-Free Quantum Dots for Biophotonics and Nanomedicine
Xu, G., Zeng, S., Zhang, B., Swihart, M. T., Yong, K.-T., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00290 · Cited by 587
Algar, W. R., Tavares, A. J., & Krull, U. J. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.05.026 · Cited by 511
Optical methods for sensing glucose
Steiner, M.-S., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 497
Recent advances in enzyme immobilization techniques: Metal-organic frameworks as novel substrates
Mehta, J., Bhardwaj, N., Bhardwaj, S. K., Kim, K.-H., & Deep, A. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2016.05.007 · Cited by 446
BSA-templated MnO2 nanoparticles as both peroxidase and oxidase mimics
Liu, X., Wang, Q., Zhao, H., Zhang, L., Su, Y., & Lv, Y. (2012) · The Analyst · doi:10.1039/c2an35700c · Cited by 426
Glucose Sensing in Supramolecular Chemistry
Sun, X., & James, T. D. (2015) · Chemical Reviews · doi:10.1021/cr500562m · Cited by 386
Nanosensors and nanomaterials for monitoring glucose in diabetes
Cash, K. J., & Clark, H. A. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.08.002 · Cited by 369
Yuan, J., Cen, Y., Kong, X.-J., Wu, S., Liu, C.-L., Yu, R.-Q., & Chu, X. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b02188 · Cited by 358
Fluorescent nanoparticles for intracellular sensing: A review
Ruedas-Rama, M. J., Walters, J. D., Orte, A., & Hall, E. A. H. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.09.025 · Cited by 321
Shi, W., Zhang, X., He, S., & Huang, Y. (2011) · Chemical Communications · doi:10.1039/c1cc14300j · Cited by 308
Zhang, C., Yuan, Y., Zhang, S., Wang, Y., & Liu, Z. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201100769 · Cited by 288
H. R, C., Schiffman, J. D., & Balakrishna, R. G. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.11.189 · Cited by 286
Metadata
- Authors
- Wu, P., He, Y., Wang, H.-F., & Yan, X.-P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-21
- Volume
- 82
- Issue
- 4
- Pages
- 1427-1433
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2028319667
- Cited by
- 345
- References
- 32
- FWCI
- 22.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.