Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.

Self-Powered Wearable Biosensors

Open access
Song, Yu, Mukasa, Daniel, Zhang, Haixia, Gao, Wei · 2021 · Accounts of Materials Research

Abstract

Conspectus: Wearable biosensors hold the potential of revolutionizing personalized healthcare and telemedicine. Advances in chemical sensing, flexible materials, and scalable manufacturing techniques now allow wearables to detect key physiological indicators such as temperature, vital signs, body motion, and molecular biomarkers. With these systems operating on the skin, they enable continuous and noninvasive disease diagnosis and health monitoring. Such complex devices, however, require suitable power sources in order to realize their full capacity. Emerging wearable energy harvesters are attractive for addressing the challenges of a wearable power supply. These harvesters convert various types of ambient energy sources (e.g., biomechanical energy, biochemical energy, and solar energy) into electricity. In some circumstances, the harvested electrical signals can directly be used for active sensing of physiological parameters. On the other hand, single or hybrid wearable energy harvesters, when integrated with power management circuits and energy storage devices, could power additional biosensors as well as signal processing and data transmission electronics. Self-powered sensor systems operate continuously and sustainably without an external power supply are promising candidates in the next generation of wearable electronics and the Internet of Things. This Account highlights recent progress in self-powered wearable sensors toward personalized healthcare, covering biosensors, energy harvesters, energy storage, and power supply strategies. The Account begins with an introduction of our wearable biosensors toward an epidermal detection of physiological information. Advances in structural and material innovations enable wearable systems to measure both biophysical and biochemical indicators conformably, accurately, and continuously. We then discuss emerging technologies in wearable energy harvesting, classified according to their capability to scavenge energy from various sources. These include examples of using energy harvesters themselves as active biosensors. Through seamless integration and efficient power management, self-powered wireless wearable sensor systems allow real-time data acquisition, processing, and transmission for health monitoring. The final section of the Account covers the existing challenges and new opportunities for self-powered wearable sensors in health monitoring and human–machine interfaces toward personalized and precision medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/accountsmr.1c00002

Cites

69 of 69 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 68 references

Cited by

See all 237

Metadata

Authors
Song, Y., Mukasa, D., Zhang, H., & Gao, W.
Affiliations
  • California Institute of Technology (US)
  • Peking University (CN)
Corresponding author
Gao, Wei
Venue
Accounts of Materials Research
Published
2021-02-14
Volume
2
Issue
3
Pages
184-197
ISSN
2643-6728 (ISSN-L)
OpenAlex
W4247234299
Cited by
237
References
68
Citations by year
2026: 35 · 2025: 40 · 2024: 50 · 2023: 48 · 2022: 44 · 2021: 20
FWCI
12.29
Type
journal article
Language
en
Open access
Locations
  • Accounts of Materials Research (publishedVersion, other-oa)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
Funders
  • American Heart Association (19TPA34850157)
  • Tobacco-Related Disease Research Program (T31IP1666)
  • California Institute of Technology (NA)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
Keywords
wearable energy harvester, energy storage, power management circuit, epidermal sensors, physiological monitoring, biochemical sensing, biomechanical energy harvesting, solar energy harvesting, wearable wireless sensors, human-machine interaction, personalized healthcare, telemedicine, flexible electronics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Powered Wearable Biosensors. https://app.cochat.ai/papers/10.1021/accountsmr.1c00002
The paper
Song, Y., Mukasa, D., Zhang, H., & Gao, W. (2021). Self-Powered Wearable Biosensors. Accounts of Materials Research. https://doi.org/10.1021/accountsmr.1c00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.