Self-Powered Wearable Biosensors
Open accessThe DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
Conspectus: Wearable biosensors hold the potential of revolutionizing personalized healthcare and telemedicine. Advances in chemical sensing, flexible materials, and scalable manufacturing techniques now allow wearables to detect key physiological indicators such as temperature, vital signs, body motion, and molecular biomarkers. With these systems operating on the skin, they enable continuous and noninvasive disease diagnosis and health monitoring. Such complex devices, however, require suitable power sources in order to realize their full capacity. Emerging wearable energy harvesters are attractive for addressing the challenges of a wearable power supply. These harvesters convert various types of ambient energy sources (e.g., biomechanical energy, biochemical energy, and solar energy) into electricity. In some circumstances, the harvested electrical signals can directly be used for active sensing of physiological parameters. On the other hand, single or hybrid wearable energy harvesters, when integrated with power management circuits and energy storage devices, could power additional biosensors as well as signal processing and data transmission electronics. Self-powered sensor systems operate continuously and sustainably without an external power supply are promising candidates in the next generation of wearable electronics and the Internet of Things. This Account highlights recent progress in self-powered wearable sensors toward personalized healthcare, covering biosensors, energy harvesters, energy storage, and power supply strategies. The Account begins with an introduction of our wearable biosensors toward an epidermal detection of physiological information. Advances in structural and material innovations enable wearable systems to measure both biophysical and biochemical indicators conformably, accurately, and continuously. We then discuss emerging technologies in wearable energy harvesting, classified according to their capability to scavenge energy from various sources. These include examples of using energy harvesters themselves as active biosensors. Through seamless integration and efficient power management, self-powered wireless wearable sensor systems allow real-time data acquisition, processing, and transmission for health monitoring. The final section of the Account covers the existing challenges and new opportunities for self-powered wearable sensors in health monitoring and human–machine interfaces toward personalized and precision medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Recent advances in wireless charging and self-powered technologies have been established to limit the number of times a user must undergo replacement surgery.[326]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [326]
Experimental — accuracy not yet measuredIn the citing paper
“For example, lactate has the potential to be an outstanding fuel for self-powered wearable devices as it can be easily oxidized by oxidase enzymes (lactate oxidase or lactate dehydrogenase) and its concentration in sweat is relatively abundant (in the millimolar range)204,205.”
From End-to-end design of wearable sensors (2022) · cites this paper as [205]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn404614z · Cited by 3,058 · cited 1×
“43 Emerging wearable energy harvesters can be categorized by their energy sources, including mechanical energy, biochemical energy, and solar energy.”
Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
Energy storage: The future enabled by nanomaterials
Pomerantseva, E., Bonaccorso, F., Feng, X., Cui, Y., & Gogotsi, Y. (2019) · Science · doi:10.1126/science.aan8285 · Cited by 1,927
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884 · cited 1×
“24 Figure 2A shows a porous piezoresistive pressure sensor based on a carbon nanotube − poly-(dimethylsiloxane) (CNT-PDMS) conductive elastomer through a solution-evaporation fabrication method.”
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Self-citationA laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Self-citation
Cited by
Items 201–237 of 237
Vasquez-Cevallos, L., Rodriguez, P. E. D. S., & Salazar, P. (2026) · Applied Sciences · doi:10.3390/app16178391 · Cited by 1
Electrochemical Flow Injection Analysis Biosensors Using Biomolecules-immobilized Carbon Felt
Hasebe, Y., & Wang, Y. (2022) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.71.13 · Cited by 1
Choi, E., & Kim, S. W. (2025) · International Journal of Students Research in Technology & Management · doi:10.18510/ijsrtm.2025.1311 · Cited by 1
“However, despite several platforms (Kim et al., 2018 & Song et al., 2021 & Smith et al., 2023) undergoing clinical evaluation, their commercial market success remains limited.”
Shukla, S. K., & Singh, N. B. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00011-9 · Cited by 1
Types of Surface Modifications of Carbon Nanotubes
Roghani‐Mamaqani, H., & Mardani, H. (2022) · ACS symposium series · doi:10.1021/bk-2022-1424.ch004 · Cited by 1
Chung, M., Sanchez, F. J. D., Schoeller, J., Stämpfli, R., Rossi, R. M., & Radacsi, N. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4113140 · Cited by 1
Zhang, Y., Zhu, H., Ying, Z., Gao, X., Chen, W., Zhan, Y., Feng, L., Liu, C., & Dai, Y. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.01.17.476350
Minimally-invasive and non-invasive flexible devices for robust characterizations of deep tissues
Yuan, Y., Tang, W., Wu, H., Chen, S., Ren, X., Hu, B., & Gu, N. (2022) · Scientia Sinica Chimica · doi:10.1360/ssc-2022-0100
Gonzalez-Losada, P., Martins, M., & Vinayakumar, K. B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3229771
“Recently, several review articles discussed the use of self-powered sensors for wearable applications, such as cardiac health monitoring, human activity, or biosensors [48], [49].”
BackgroundRecent Progress on Non-invasive Wearable Epidermal Biosensors
Li, B. (2023) · Theoretical and Natural Science · doi:10.54254/2753-8818/4/20220536
Zhang, J., Huang, L., Chen, M., Wang, H., Wang, C., Yang, C., Zhou, H., Wang, Y., Fang, Z., & Gao, Z. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4866678
Tsujimura, S. (2024) · Carbon Reports · doi:10.7209/carbon.030404
Self-powered sensors for healthcare
Aziz, A., Amjad, I., Hafeez, M., Rana, U., Nabi, G., Butt, F. K., Bajwa, S. Z., & Khan, W. S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00023-5
Light-Emitting Materials for Wearable Bioelectronics
Okmi, A. (2025) · Engineering materials · doi:10.1007/978-3-031-88731-4_7
Introduction of Intelligent Biomaterials
Liu, Z., & Shi, Y. (2025) · Springer eBooks · doi:10.1007/978-981-96-8646-9_1
Nanotechnology enabled smart biosensors in monitoring and maintaining balanced health: A Review
Mohite, P. B., Puri, A. V., Munde, S. V., Yadav, V., Ade, N., & Singh, S. (2024) · Nanofabrication · doi:10.37819/nanofab.9.2018
Computer-Based Wearable Devices for Remote Patient Monitoring
Anura, A., & Maji, D. (2025) · Springer eBooks · doi:10.1007/978-981-96-9346-7_7
Smart wearable medical monitoring devices
Roychoudhury, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26492-4.00006-2
Advances and impacts of biofuel applications on environment and global economy
Onwosi, C. O., Igbokwe, V. C., Ezugworie, F. N., & Onyishi, C. L. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21527-8.00016-2
Chen, Z., & Ran, W. (2025) · Sensor Review · doi:10.1108/sr-06-2025-0410
Advancements in Wireless-Enabled Wearable Biosensors for Real-Time Fatigue Monitoring: A Review
Mohammed, A. S., Podder, P., & Zawodniok, M. J. (2026) · Lecture notes in networks and systems · doi:10.1007/978-981-96-9184-5_49
Luo, X., Ling, X., Li, X., Wang, Z., & Hu, X. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.5c04604 · Cited by 1
Physical Sensors in Wearable Systems for Motion and Health Monitoring
Du, S., Li, Z., & Liu, H. (2026) · Springer eBooks · doi:10.1007/978-3-032-02713-9_17
Challenges in Paper-Based Sensors and ePADs, and Trends in Their Development
Korotcenkov, G. S. (2026) · Springer eBooks · doi:10.1007/978-3-032-02713-9_27
Sunil, M., Jelmy, E. J., Rajesh, T., Saji, K. J., & John, H. (2026) · ACS Applied Engineering Materials · doi:10.1021/acsaenm.6c00106
Moradi, S., Firoozbakhtian, A., Hosseini, M., Xu, G., & Shahab, K. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118091 · Cited by 1
Liu, W., Wang, Y., Lei, M., Yin, Y., Ding, J., Qian, J., Wang, K., & Wei, J. (2026) · Applied Materials Today · doi:10.1016/j.apmt.2026.103319
Wearable Electronics for Precision Diagnosis Through Advanced Manufacturing and Integration
Gong, X., Zheng, Y., Ding, X., Gao, J., Cheng, B., Shao, X., Li, J., Jiang, L., Haick, H., & Yang, J. (2026) · Nano-Micro Letters · doi:10.1007/s40820-026-02311-8
Nuro, J., Inam, A. K. M. S., & Tabassum, S. (2026) · IEEE Electron Devices Magazine · doi:10.1109/med.2026.3704354
“In parallel, self-powered architectures based on energy harvesting aim to reduce dependence on bulky batteries and support longer-term operation of wearable sweat biosensors [7].”
Near‐Field Communication‐Enabled Wearable Chemical Sensors for Bioanalytical Monitoring
Che, H., Gao, S., Chen, S., Xu, J., Dong, Z., Bai, Y., & Lin, Y. (2026) · Chemistry - An Asian Journal · doi:10.1002/asia.70975
Bioinspired Low‐Power Mechanical Sensing Technologies
Zhang, X., Zhang, X., Huang, X., Li, B., Zhang, C., Meng, X., Chen, G., Chen, Y., Zhang, J., Niu, S., et al. (2026) · Advanced Materials · doi:10.1002/adma.75090
Dai, C., Gao, B., Wu, Z., Huang, Y., & Ahmadian, A. (2026) · Digest Journal of Nanomaterials and Biostructures · doi:10.31083/djnb52248
Kazanskiy, N. L., Golovastikov, N. V., & Khonina, S. N. (2026) · Sensors · doi:10.3390/s26196277
Self-powered analytical chemistry: Concept, functionality with circular and eco-design
Hussain, C. M., Hussain, G., & Keçili, R. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.119185
A biohybrid mesh harvester for distributed energy harvesting in living tissues
Wang, S., Wang, X., Fu, S., Senger, C., Pfund, J. D., Jain, M., Katsumata, R., & Yao, J. (2026) · Science Advances · doi:10.1126/sciadv.aei5963
“Among them, the concept of converting on-site biomechanical, biochemical, and biothermal energy has received considerable attention ( 11 – 13 ), as leveraging these bio-origin sources may fundamentally reduce the mismatch in energy sustainability between electronic and biological systems.”
Lahcen, A. A., & Slaughter, G. E. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1967612
Bachhar, V., Joshi, V., Wu, C.-H., Lin, W.-C., Tsai, C.-I., Duseja, M., Chang‐Chien, G., & Kogularasu, S. (2026) · Environmental Research · doi:10.1016/j.envres.2026.126033
Metadata
- Authors
- Song, Y., Mukasa, D., Zhang, H., & Gao, W.
- Affiliations
- California Institute of Technology (US)
- Peking University (CN)
- Corresponding author
- Gao, Wei
- Venue
- Accounts of Materials Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-02-14
- Volume
- 2
- Issue
- 3
- Pages
- 184-197
- ISSN
- 2643-6728 (ISSN-L)
- OpenAlex
- W4247234299
- Cited by
- 237
- References
- 68
- Citations by year
- 2026: 35 · 2025: 40 · 2024: 50 · 2023: 48 · 2022: 44 · 2021: 20
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Accounts of Materials Research (publishedVersion, other-oa)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- American Heart Association (19TPA34850157)
- Tobacco-Related Disease Research Program (T31IP1666)
- California Institute of Technology (NA)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Keywords
- wearable energy harvester, energy storage, power management circuit, epidermal sensors, physiological monitoring, biochemical sensing, biomechanical energy harvesting, solar energy harvesting, wearable wireless sensors, human-machine interaction, personalized healthcare, telemedicine, flexible electronics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.