Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
The DOI matches its Crossref record; 38 of the 40 references it cites were found in a registry or an index.
Abstract
Physiological sensors in a wearable form have rapidly emerged on the market due to technological breakthroughs and have become nearly ubiquitous with the Apple Watch, FitBit, and other wearable devices. While these wearables mostly monitor simple biometric signatures, new devices that can report on the human readiness level through sensing molecular biomarkers are critical to optimizing the human factor in both commercial sectors and the Department of Defense. The military is particularly interested in real-time, wearable, minimally invasive monitoring of fatigue and human performance to improve the readiness and performance of the war fighter. However, very few devices have ventured into the realm of reporting directly on biomarkers of interest. Primarily this is because of the difficulties of sampling biological fluids in real-time and providing accurate readouts using highly selective and sensitive sensors. When additional restrictions to only use sweat, an excretory fluid, are enforced to minimize invasiveness, the demands on sensors becomes even greater due to the dilution of the biomarkers of interest, as well as variability in salinity, pH, and other physicochemical variables which directly impact the read-out of real-time biosensors. This Account will provide a synopsis not only on exemplary demonstrations and technological achievements toward implementation of real-time, wearable sweat sensors but also on defining problems that still remain toward implementation in wearable devices that can detect molecular biomarkers for real world applications. First, the authors describe the composition of minimally invasive biofluids and then identify what biomarkers are of interest as biophysical indicators. This Account then reviews demonstrated techniques for extracting biofluids from the site of generation and transport to the sensor developed by the authors. Included in this discussion is a detailed description on biosensing recognition elements and transducers developed by the authors to enable generation of selective electrochemical sensing platforms. The authors also discuss ongoing efforts to identify biorecognition elements and the chemistries necessary to enable high affinity, selective biorecognition elements. Finally, this Account presents the requirements for wearable, real-time sensors to be (1) highly stable, (2) portable, (3) reagentless, (4) continuous, and (5) responsive in real-time, before delving into specific methodologies to sense classes of biomarkers that have been explored by academia, government laboratories, and industry. Each platform has its areas of greatest utility, but also come with corresponding weaknesses: (1) ion selective electrodes are robust and have been demonstrated in wearables but are limited to detection of ions, (2) enzymatic sensors enable indirect detection of metabolites and have been demonstrated in wearables, but the compounds that can be detected are limited to a subset of small molecules and the sensors are sensitive to flow, (3) impedance-based sensors can detect a wide range of compounds but require further research and development for deployment in wearables. In conclusion, while substantial progress has been made toward wearable molecular biosensors, substantial barriers remain and need to be solved to enable deployment of minimally invasive, wearable biomarker monitoring devices that can accurately report on psychophysiological status.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“its application has been limited to date (Brothers et al. 2019; Gao et al. 2018; Heikenfeld et al. 2018).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Brothers et al. 2019
In the citing paper
“Most publications on sweat diagnostics have primarily focused on the development of skin-interfaced platforms capable of capturing and performing quantitative measurements of sweat chemistry.”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Brothers et al. 2019
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationA Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Research works printed but not linked: 2
- Heikenfeld J., 2019, Nat. Biotechnol.
- Bühlmann P., 2012, Supramolecular Chemistry: From Molecules to Nanomaterials, 2539
Cited by
Items 101–200 of 210
Kangarshahi, B. M., Sojdeh, S., Daneshgar, H., Bagherzadeh, M., Naghib, S. M., & Rabiee, N. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.118062 · Cited by 27
Liang, C., Liu, J., Zhang, H., Zhang, Z., Liu, Y., Zhang, K., & Wang, T. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.164477 · Cited by 23
Ban, S., Yi, H., Park, J., Huang, Y., Yu, K. J., & Yeo, W. (2025) · Advanced Materials · doi:10.1002/adma.202416899 · Cited by 27
Yuan, Y., DeBrosse, M. C., Brothers, M. C., Kim, S. S., Sereda, A., Ivanov, N. V., Hussain, S. M., & Heikenfeld, J. C. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c14175 · Cited by 23
Self-citationRecent trends in non-invasive on-body chemical sensing
Boeva, Z. A., Mousavi, Z., Sokalski, T., & Bobacka, J. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117542 · Cited by 25
Brouzgou, A., Vecchio, C. L., Baglio, V., Aricò, A. S., Liang, Z., Demin, A. K., & Tsiakaras, P. E. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113610 · Cited by 23
Catalytic Nucleic Acids for Bioanalysis
Mao, X., Li, Q., Zuo, X., & Fan, C. (2019) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b00928 · Cited by 23
WILSON, E. K. (2019) · Engineering · doi:10.1016/j.eng.2019.04.008 · Cited by 20
Modern microfluidic approaches for determination of ions
Shi, H., Jiang, S., Liu, B., Liu, Z., & Reis, N. M. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.106845 · Cited by 19
Hossain, N. I., Sharma, A., & Sonkusale, S. (2023) · IEEE Sensors Letters · doi:10.1109/lsens.2023.3300827 · Cited by 21
Kakroudi, M. R., Lawrence, D. J., Hamid, Z., Darensbourg, J., Calvo‐Marzal, P., & Chumbimuni‐Torres, K. Y. (2022) · Electroanalysis · doi:10.1002/elan.202200121 · Cited by 21
Sun, H., Wang, S., Zhu, A., Wang, T., Wang, H., Zheng, Y., Shi, G., & Zhang, M. (2025) · ACS Sensors · doi:10.1021/acssensors.5c00271 · Cited by 21
Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2023) · Biosensors · doi:10.3390/bios14010017 · Cited by 19
Non-invasive Healthcare Analytical Platform Based on Organic Electrochemical Transistors
Hu, X., Mao, N., Yan, X., Huang, L. F., Liu, X., Yang, H., Sun, Q., Liu, X., & Jia, H. (2024) · Chemical Research in Chinese Universities · doi:10.1007/s40242-024-4176-4 · Cited by 19
Su, M., Dong, W., Liang, A., & Chen, X. (2026) · Talanta · doi:10.1016/j.talanta.2026.129652 · Cited by 17
Li, Z., Li, T., Wang, X., Ping, J., & Peng, H. (2024) · Talanta · doi:10.1016/j.talanta.2024.126883 · Cited by 17
Weaving Off‐The‐Shelf Yarns into Textile Micro Total Analysis Systems (μTAS)
Månsson, I. Ö., Piper, A., & Hamedi, M. M. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000150 · Cited by 18
Debnath, S., Debnath, T., & Paul, M. (2025) · Sensors · doi:10.3390/s25216553 · Cited by 21
Wearable smart sensors integration with AI and machine learning for tracking human health
Xianyong, S., Mishra, D. K., Özcan, Ö. Ö., Karahan, M., Panpan, T., Zhongshan, X., & Kumar, P. V. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100711 · Cited by 31
Dual-Valved Skin-Interfaced Microfluidic Device for Programmed Time-Control Sweat Collection
Yang, J. H., David, U., Noh, Y. S., & Koh, A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134441 · Cited by 22
Li, G., Xie, G., Gong, C., Chen, D., Chen, X., Zhang, Q., Dong, H., Zhang, Y., Li, C., Hu, J. Y., et al. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05172-1 · Cited by 16
Liu, G., Xu, H., Zhang, P., Tan, Q., Jin, X., Dou, X., Zhao, N., & Li, C. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.139042 · Cited by 13
Recent Impact of Microfluidics on Skin Models for Perspiration Simulation
Rabost-Garcia, G., Farré‐Lladós, J., & Casals‐Terré, J. (2021) · Membranes · doi:10.3390/membranes11020150 · Cited by 13
Advancing Flexible Sensors through On-Demand Regulation of Supramolecular Nanostructures
Wu, B., Wu, T., Huang, Z., & Ji, S. (2024) · ACS Nano · doi:10.1021/acsnano.4c08310 · Cited by 14
Wearable Device for Continuous and Real-Time Monitoring of Human Sweat Sodium
Noor, A. M., Farisi, M. S. A., Mazalan, M., Ibrahim, N. F. A., Wahab, A. A., Zakaria, Z., Rusli, N. I., Sabani, N. B., & Manaf, A. A. (2025) · Sensors · doi:10.3390/s25113467 · Cited by 13
Abtew, M. A., Ahmmed, A. S., Tadesse, M. G., & Zaman, S. U. (2025) · Textile Research Journal · doi:10.1177/00405175251338152 · Cited by 16
Real-time smart multisensing wearable platform for monitoring sweat biomarkers during exercise
Lafaye, C., Rovira, M., Demuru, S., Wang, S., Kim, J., Kunnel, B. P., Besson, C., Fernández‐Sánchez, C., Serra-Graells, F., Margarit, J. M., et al. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948565 · Cited by 14
Advancements and Obstacles in Sweat-Based Biosensors for Health Monitoring
Lihong, Z., & Li, Q. (2025) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2568615 · Cited by 14
Sun, H., Chen, L., Wang, T., Li, Z., Yi, S., Lv, W., Yang, Z., Xuan, F., Zhang, M., & Shi, G. (2026) · Nano-Micro Letters · doi:10.1007/s40820-026-02095-x · Cited by 16
Smart wearable photonic array biosensor for human sweat analysis
Hussain, S., Ramadan, Q., & Zourob, M. M. (2025) · Soft Science · doi:10.20517/ss.2025.02 · Cited by 12
Self-citationMalizia, A., McGovern, J., Sarigiannis, D. A., Karakitsios, S., Anastas, P. T., Ludovici, G. M., Manenti, G., & Vasiliou, V. (2025) · The European Physical Journal Plus · doi:10.1140/epjp/s13360-025-07030-4 · Cited by 11
Mild dehydration does not alter acute changes in sweat electrolyte concentrations during exercise
Baker, L. B., Ozga, M., Merritt, J. R., Alfred, S., Chavez, P. J. D. D., & Hinkley, J. M. (2024) · Physiological Reports · doi:10.14814/phy2.16174 · Cited by 10
Sweat as a diagnostic biofluid: analytical advances and future directions
Bordin, D. M., McCauley, J. I., de Campos, E. G., Bishop, D., & Martinis, B. S. D. (2025) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2025.101473 · Cited by 11
Advances in Electrochemical Nanobiosensors for Noninvasive Stress Biomarker Detection
Messina, L., Amadoro, P., & Giardi, M. T. (2025) · Sensors · doi:10.3390/s25237255 · Cited by 10
Non-invasive electrochemistry-driven metals tracing in human biofluids
Faheem, A., & Cinti, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113904 · Cited by 9
Monoolein-Based Wireless Capacitive Sensor for Probing Skin Hydration
Chaturvedi, V., Falk, M., Björklund, S., Gonzalez-Martinez, J. F., & Shleev, S. (2024) · Sensors · doi:10.3390/s24144449 · Cited by 9
Li, S., Psihogios, A. M., McKelvey, E. R., Ahmed, A., Rabbi, M., & Murphy, S. A. (2020) · Current Opinion in Systems Biology · doi:10.1016/j.coisb.2020.07.002 · Cited by 15
Liu, G., Wang, H., Zhang, P., Liu, Y., Tan, Q., Jin, X., & Li, C. (2025) · Microchimica Acta · doi:10.1007/s00604-025-07466-6 · Cited by 9
Czopinska, J., Zaras, I., & Jarczewska, M. (2025) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2025.109204 · Cited by 8
The application of biosensors in precision medicine
Brazaca, L. C., & Sempionatto, J. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15380-8.00006-0 · Cited by 9
Zhang, X., Ma, L., Chen, J., Fu, J., Wang, J., Wang, Y., Zhu, M., Yu, M., & Chen, D. (2025) · Displays · doi:10.1016/j.displa.2025.103038 · Cited by 10
Zhang, X. Y., Liu, P., Ru-Ting, W. A. N. G., Gong, Q., & Cheng, F. A. N. G. (2024) · Chinese Journal of Analytical Chemistry · doi:10.1016/j.cjac.2024.100356 · Cited by 9
Zhu, X., Tang, X., Ng, C. A., Li, L., Lai, Y., Miller, G. W., Jiang, C., Barchowsky, A., Buchanich, J. M., & Gao, P. (2025) · Reviews of Environmental Contamination and Toxicology · doi:10.1007/s44169-025-00088-2 · Cited by 9
Dyshko, K., Nicodemus, M. P., Otterstetter, R., Ghadimi, H., Daniels, S., Fulmer, M., Cheney, Z., Ellis, R., Stege, V., & Monty, C. N. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05364-4 · Cited by 7
Lahcen, A. A., & Amine, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00011-2 · Cited by 10
Zhao, Y., Zhou, Y., Zhan, S., Wei, Y., Xu, Z., Chen, W., Ma, Y., Ye, X., & Liang, B. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118142 · Cited by 6
Reza, M. S., Song, H., Islam, M. Z., Kim, D., Go, J., & Park, J. Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.172668 · Cited by 7
Ma, N., Liu, Q., Cai, N., Zhu, F., Gan, N., & Yu, Z. (2026) · Analytica Chimica Acta · doi:10.1016/j.aca.2026.345130 · Cited by 6
Microneedles for Continuous, Minimally Invasive Monitoring: A Technology Overview
Conejo‐Cuevas, G., Pellitero, M. A., Ruiz‐Rubio, L., & del Campo, F. J. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202500057 · Cited by 7
Pojednic, R. M., Welch, A. S., THORNTON, M. K., Garvey, M. E., Grogan, T., Roberts, W., & Ash, G. I. (2024) · JMIR Formative Research · doi:10.2196/60925 · Cited by 6
Li, L., Yang, X., Kang, W., & Cheng, B. (2025) · Polymer · doi:10.1016/j.polymer.2025.128221 · Cited by 6
Manik, K. H., Nath, A., Rimi, M. A. P., Ahmed, R., Rhine, A., Hasan, M. J., Mim, J. J., & Hossain, N. (2026) · Next Materials · doi:10.1016/j.nxmate.2026.102175 · Cited by 6
A novel conductive membrane sensor protection technique to mitigate redox-active interferences
DeBrosse, M. C., Suresh, S., Karajić, A., Kim, S. S., Hussain, S. M., & Heikenfeld, J. C. (2023) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2023.100366 · Cited by 7
Self-citationThe ethical dimension of personal health monitoring in the armed forces: a scoping review
Bovens, D., van Baarle, E., Ziesemer, K. A., & Molewijk, B. C. (2024) · BMC Medical Ethics · doi:10.1186/s12910-024-01086-0 · Cited by 5
Elahi, E., Vattikuti, S. V. P., Ahmad, M., Aziz, J., Assiri, M. A., Rabeel, M., Chauhan, P., Rehman, S., Rehmat, A., Ahsan, U., et al. (2025) · Materials Today Chemistry · doi:10.1016/j.mtchem.2025.102886 · Cited by 5
Micro elastofluidic liquid diode for programmable unidirectional flow control
Cha, H., Galogahi, F. M., Trịnh, Q. T., Yadav, S., Zhang, J., An, H., Li, Q., & Nguyen, N. (2025) · Lab on a Chip · doi:10.1039/d5lc00438a · Cited by 4
Wearable Sensors for Detecting Biomarkers in Sweat: A Systematic Review
Du, Z., Li, J., Ding, Y., Su, Z., Li, J., Feng, Y., Ren, H., Yang, H., Fang, X., Zheng, J., et al. (2026) · ChemistryEurope · doi:10.1002/ceur.202500393 · Cited by 4
Jalali, P., & Sanati‐Nezhad, A. (2026) · Lab on a Chip · doi:10.1039/d5lc01172h · Cited by 4
Advances in Wearable Biosensors for Non-Invasive Biofluid Monitoring
Mondal, R., & Saikia, M. J. (2026) · Biosensors · doi:10.3390/bios16060336 · Cited by 4
Wallace, S. G., Brothers, M. C., Brooks, Z., Rangnekar, S. V., Lam, D. K., Lawrence, M. S., Rojas, W. A. G., Putz, K. W., Kim, S. S., & Hersam, M. C. (2022) · Engineering Research Express · doi:10.1088/2631-8695/ac5e27 · Cited by 5
Self-citationAbdullahi, S., Zhu, Y., Gama, M. I. H., Omer, M. O. M., Wang, Q., Yakubu, A., & Nie, Z. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100231 · Cited by 5
DeBrosse, M. C., Yuan, Y., Brothers, M. C., Karajić, A., van Duren, J., Kim, S. S., Hussain, S. M., & Heikenfeld, J. C. (2021) · Sensors · doi:10.3390/s21238063 · Cited by 4
Self-citationNano-inspired Point-of-Care Enzyme-Based Wearable Biosensors for Global Health Care
Kumar, V., & Arora, K. (2023) · Springer eBooks · doi:10.1007/978-981-15-6982-1_13 · Cited by 6
Future Visions of Personalized and Precision Nutrition
Heber, D., & Li, Z. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15315-0.00018-3 · Cited by 3
Xia, R., Cai, X. M., Lin, J.-Y., Zhao, Y., Liu, Z.-H., Wang, C., Chen, S.-H., Yang, M., Song, Z., Li, P., et al. (2025) · Chemical Science · doi:10.1039/d5sc01241d · Cited by 3
Printed Sensors for Quantifying Electrodermal Activity and Sweat Rate: A Review
Hosseinzadeh, B., Tonello, S., Lopomo, N. F., & Sardini, E. (2025) · Sensors · doi:10.3390/s25226878 · Cited by 5
Wearable sweat induction strategies for noninvasive biosensing
He, Y., Qiao, Y., Shang, J., Gan, H., Zhu, X., He, X., Zhang, H., & Qigong, L. (2025) · Talanta · doi:10.1016/j.talanta.2025.129294 · Cited by 3
A Flexible Enzymatic Sensor for Glucose and Uric Acid Detection in Sweat
Wang, M., Lou, H., You, Z., Zheng, H., & Jiang, L. (2025) · Russian Journal of Electrochemistry · doi:10.1134/s1023193525600051 · Cited by 2
Esfandiar, M., Hosseinalipour, S. M., & Salehi, S. M. (2026) · Engineering Reports · doi:10.1002/eng2.70593 · Cited by 2
Sempionatto, J. R., & Gao, W. F. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00010-0 · Cited by 3
Li, Z., Sun, H., Wang, T., Ni, W., Zhu, J., Cheng, W., Zhang, B., Xuan, F., Yang, J., Zeng, M., et al. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10785051 · Cited by 1
Brothers, M. C., Sim, J. K., Sant’Anna, G., Giordano, A. N., Rao, R. S., Bedford, N. M., & Kim, S. S. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c14021 · Cited by 2
Self-citationLv, F., Zhao, R., Chen, Z., Wang, S., Huang, Y., & Wang, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116245 · Cited by 1
An innovative diagnostic method for myopia using blood-based biomemristor
Liu, Z., Ren, X., Sun, B. T., Zhou, G., Gao, H. Q., Bi, J., Cao, Z., Gao, K., Ma, H., & Lu, Y. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102350 · Cited by 1
He, J., Sun, B., Wang, S., Chen, Q., Cao, Z., Gao, K., Wang, M., Wu, T., Fu, L., Wang, K., et al. (2026) · Materials Today Chemistry · doi:10.1016/j.mtchem.2026.103685 · Cited by 1
Non-Invasive Technologies in Wearable Glucose Monitoring: A Structured Overview for the Future
Imran, A., Ramzan, M. B., Hashmi, L., Qureshi, S. M., Raza, M., & Zaman, S. U. (2026) · Biosensors · doi:10.3390/bios16080407 · Cited by 2
Functional hydrogel bioelectronic interfaces
Jiang, X., Chen, G., Wu, D., Li, C., Fang, J. Y., & Niu, S. (2026) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2026.101287 · Cited by 1
Wearable biosensors for monitoring of disease-related biomarkers
Campuzano, S., Yáñez‐Sedeño, P., & Pingarrón, J. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822859-3.00011-0 · Cited by 1
Yang, Q., Nguyen, E. P., Silva, C. D. C. C., Rosati, G., & Merkoçi, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00005-7 · Cited by 3
Afzali, D., & Afzali, M. (2023) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-023-02869-9 · Cited by 1
Lu, D., Yang, C., Chen, L., Cao, C., Xia, W., Li, G., & Wen, D. (2023) · Electroanalysis · doi:10.1002/elan.202300385 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 2
Self-citationAskari, V. R., Roudi, H. S., Safaei, R., Slamani, N., Nikfarjam, M., Shirazi, S. S., Fadaei, M. S., Hasnain, M. S., & Nayak, A. K. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21658-9.00018-8 · Cited by 1
Wang, J., Wang, S., & Zhang, J. (2025) · Flexible and Printed Electronics · doi:10.1088/2058-8585/adb8fa · Cited by 2
Smart Nanomaterials for Injury Prevention and Recovery
Goswami, R., Das, S., Basu, D., Wong, T. W., Laha, S., Roy, S., & Bose, A. (2025) · Smart nanomaterials technology · doi:10.1007/978-981-96-5471-0_11 · Cited by 1
Nagamine, K., & Tokito, S. (2020) · Denki Kagaku · doi:10.5796/denkikagaku.20-fe0031
Chiriacò, M. S., Ferrara, F., & Primiceri, E. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-3415-2
Progress of Flexible Wearable Electrochemical Sensors for Human Sweat Detection
曹, 小. (2022) · Advances in Analytical Chemistry · doi:10.12677/aac.2022.123033
Photonic Integrated Circuit (PIC) Platform for Sensing Biomarkers
Morales, J. M., Bickford, J. R., Cho, P. S., & Pellegrino, P. M. (2022) · Optical Sensors and Sensing Congress · doi:10.1364/sensors.2022.sm3e.1
He, M., Huang, S., Zheng, S., Yao, C., Liu, Z., Huang, X., Li, X., Liang, B., Wang, J., Li, Y., et al. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202300735
Electrochemical analysis of biological fluids
Brown, M. S., Kelly, M., & Koh, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99147-6.00003-x
Application and Development of Wearable Sensing Devices for Health Monitoring of the Elderly
Guo, P. (2024) · International Conference on Electrical Drives, Power Electronics & Engineering (EDPEE) · doi:10.1109/edpee61724.2024.00093
Integrating Wearable Sensor Data and Neural Networks for Real-Time Electrolyte Prediction
Kumar, D. (2025) · Biomedical Materials & Devices · doi:10.1007/s44174-025-00524-w
Bovens, D., van Baarle, E., Ziesemer, K. A., & Molewijk, B. C. (2024) · Figshare · doi:10.6084/m9.figshare.26759114
Wearable Electrochemical Sensor Based on Laser-Induced Graphene on Adhesive Bandage
Souza, L. K. A., Bridges, M. M., Baldo, T. A., Coltro, W. K. T., & Henry, C. S. (2026) · ECS Sensors Plus · doi:10.1149/2754-2726/ae318d · Cited by 2
Späth, J., & Bubb, C. A. B. (2026) · AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie · doi:10.1055/a-2688-2245
Gold-Decorated 3D ZnO Tetrapods Enabling Enhanced Electrochemical Sensing of Cortisol
Shukla, S., Pamshong, M., Kharthangmaw, I., Gaddimath, S., Abdullah, H., Khan, A. A., Alanazi, A. M., Mishra, Y. K., & Haldorai, Y. (2026) · BioNanoScience · doi:10.1007/s12668-026-02458-z
Neuroenhancement in Military Personnel: Conceptual and Methodological Promises
Wester, B., Feltman, K. A., Greenwald, H., van Erp, J. B. F., Ohiri, K., Heaton, K. J., Hamilton, L., Beaudoin, M., Brunyé, T. T., Vartanian, O., et al. (2024) · TNO Repository
Recent advances in wearable sensors for uric acid detection: Methods, devices, and outlooks
Hu, Y., Chu, H., Liu, X., Zhou, Z., Liao, X., Hu, L., & Yu, X. (2026) · Wearable electronics. · doi:10.1016/j.wees.2026.04.002
Guan, Y., Zhang, Q., Su, J., Yuhang, J., Wei, X., Xinlun, Y., Wang, Z., Jinchu, Y., Zhou, B., Limin, L., et al. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118106 · Cited by 1
Metadata
- Authors
- Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S.
- Affiliations
- United States Air Force Research Laboratory (US)
- University of Cincinnati (US)
- Corresponding author
- Kim, Steve S.
- ORCID
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-28
- Volume
- 52
- Issue
- 2
- Pages
- 297-306
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2911438952
- Cited by
- 207
- References
- 40
- Citations by year
- 2026: 24 · 2025: 42 · 2024: 32 · 2023: 31 · 2022: 26 · 2021: 26 · 2020: 19 · 2019: 7
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Accounts of Chemical Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Novartis
- Los Alamos National Laboratory
- Air Force Research Laboratory
- Division of Industrial Innovation and Partnerships (IIP-1738617)
- Genentech
- Amgen
- GlaxoSmithKline
- Teknologian Tutkimuskeskus VTT
- U.S. Air Force
- ESI Group
- Corteva Agriscience
- ALine, Inc.
- Corning Incorporated
- Beckman Coulter, Inc.
- KWS SAAT SE
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- sweat sensors, wearable biosensors, real-time sensing, sweat biomarkers, human performance monitoring, ion-selective electrodes, enzyme biosensor, electrochemical sensor, optical sensors, electrochemical impedance spectroscopy, potentiometric sensors, continuous monitoring, biorecognition elements, sweat pH, sweat osmolality
- MeSH terms
- Wearable Electronic Devices, Humans, Monitoring, Physiologic, Sweat, Biosensing Techniques, Biomarkers, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.