Abstract
A major limitation of intact protein fragmentation is the lack of sequence coverage within proteins’ interiors. We show that collisionally activated dissociation (CAD) produces extensive internal fragmentation within proteins’ interiors that fill the existing gaps in sequence coverage, including disulfide loop regions that cannot be characterized using terminal fragments. A barrier to the adoption of internal fragments is the lack of methods for their generation and assignment. To provide these, we explore the effects of protein size, mass accuracy, internal fragment size, CAD activation energy, and data preprocessing upon the production and identification of internal fragments. We also identify and mitigate the major source of ambiguity in internal fragment identification, which we term “frameshift ambiguity.” Such ambiguity results from sequences containing any “middle” portion surrounded by the same composition on both termini, which upon fragmentation can produce two internal fragments of identical mass, yet out of frame by one or more amino acids (e.g., TRAIT producing TRAI or RAIT). We show that such instances permit the a priori assignment of the middle sequence portion. This insight and our optimized methods permit the unambiguous assignment of greater than 97% of internal fragments using only the accurate mass. We show that any remaining ambiguity in internal fragment assignment can be removed by consideration of fragmentation propensities or by (pseudo)-MS 3 . Applying these methods resulted in a 10-fold and 43-fold expanded number of identified ions, and a concomitant 7- and 16-fold increase in fragmentation sites, respectively, for native and reduced forms of a disease-associated SOD1 variant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proteoform: a single term describing protein complexity
The Consortium for Top Down Proteomics, Smith, L. M., & Kelleher, N. L. (2013) · Nature Methods · doi:10.1038/nmeth.2369 · Cited by 1,528
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Self-citationComplete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Kou, Q., Xun, L., & Liu, X. (2016) · Bioinformatics · doi:10.1093/bioinformatics/btw398 · Cited by 276
Li, H., Nguyen, H. H., Ogorzalek Loo, R. R., Campuzano, I. D. G., & Loo, J. A. (2018) · Nature Chemistry · doi:10.1038/nchem.2908 · Cited by 249
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Guner, H., Close, P. L., Cai, W., Zhang, H., Peng, Y., Gregorich, Z. R., & Ge, Y. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0789-4 · Cited by 73
Schmitt, N. D., & Agar, J. N. (2017) · Journal of Mass Spectrometry · doi:10.1002/jms.3953 · Cited by 29
Self-citation
Cited by
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Self-citationProteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202200721 · Cited by 54
Proteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie · doi:10.1002/ange.202200721 · Cited by 6
Metadata
- Authors
- Schmitt, N. D., Berger, J. M., Conway, J. B., & Agar, J. N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-04-12
- Volume
- 93
- Issue
- 16
- Pages
- 6355-6362
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3156913125
- Cited by
- 39
- References
- 10
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increasing Top-Down Mass Spectrometry Sequence Coverage by an Order of Magnitude through Optimized Internal Fragment Generation and Assignment. https://app.cochat.ai/papers/10.1021/acs.analchem.0c04670
- The paper
- Schmitt, N. D., Berger, J. M., Conway, J. B., & Agar, J. N. (2021). Increasing Top-Down Mass Spectrometry Sequence Coverage by an Order of Magnitude through Optimized Internal Fragment Generation and Assignment. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.0c04670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.