CoChat

Universal and Programmable Rolling Circle Amplification-CRISPR/Cas12a-Mediated Immobilization-Free Electrochemical Biosensor

Qing, Min, Chen, Sheng Liang, Sun, Zhe, Fan, Yi, Luo, Hong Qun, Li, Nian Bing · 2021 · Analytical Chemistry
Cited by 181

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

The development of a sensing platform with high sensitivity and specificity, especially programmability and universal applicability, for the detection of clinically relevant molecules is highly valuable for disease monitoring and confirmation but remains a challenge. Here, for the first time, we introduce the clustered regularly interspaced short palindromic repeats (CRISPR)/Cas system into an immobilization-free electrochemical biosensing platform for sensitively and specifically detecting the disease-related nucleic acids and small molecules. In this strategy, a modular rolling circle amplification (RCA) is designed to transform and amplify the target recognition event into the universal trigger DNA strand that is used as the trigger to activate the deoxyribonuclease activity of CRISPR/Cas12a for further signal amplification. The cleavage of the target-activated blocker probe allows the methylene blue-labeled reporter probes to be captured by the reduced graphene oxide-modified electrode, leading to an obviously increased electrochemical signal. We only need to simply tune the sequence for target recognition in RCA components, and this strategy can be flexibly applied to the highly sensitive and specific detection of microRNAs, Parvovirus B19 DNA, and adenosine-5'-triphosphate and the calculated limit of detection is 0.83 aM, 0.52 aM, and 0.46 pM, respectively. In addition, we construct DNA logic circuits (YES, NOT, OR, AND) of DNA inputs to experimentally demonstrate the modularity and programmability of the stimuli-responsive RCA-CRISPR/Cas12a system. This work broadens the application of the CRISPR/Cas12a system to the immobilization-free electrochemical biosensing platform and provides a new thinking for developing a robust tool for clinical diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c00805

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 181

Metadata

Authors
Qing, M., Chen, S. L., Sun, Z., Fan, Y., Luo, H. Q., & Li, N. B.
Venue
Analytical Chemistry
Published
2021-05-13
Volume
93
Issue
20
Pages
7499-7507
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3163909596
Cited by
181
References
36
FWCI
8.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.