On-Chip Construction of Liver Lobule-like Microtissue and Its Application for Adverse Drug Reaction Assay
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Engineering the liver in vitro is promising to provide functional replacement for patients with liver failure, or tissue models for drug metabolism and toxicity analysis. In this study, we describe a microfluidics-based biomimetic approach for the fabrication of an in vitro 3D liver lobule-like microtissue composed of a radially patterned hepatic cord-like network and an intrinsic hepatic sinusoid-like network. The hepatic enzyme assay showed that the 3D biomimetic microtissue maintained high basal CYP-1A1/2 and UGT activities, responded dynamically to enzyme induction/inhibition, and preserved great hepatic capacity of drug metabolism. Using the established biomimetic microtissue, the potential adverse drug reactions that induced liver injury were successfully analyzed via drug-drug interactions of clinical pharmaceuticals. The results showed that predosed pharmaceuticals which agitated CYP-1A1/2 and/or UGT activities would alter the toxic effect of the subsequently administrated drug. All the results validated the utility of the established biomimetic microtissue in toxicological studies in vitro. Also, we anticipate the microfluidics-based bioengineering strategy would benefit liver tissue engineering and liver physiology/pathophysiology studies, as well as in vitro assessment of drug-induced hepatotoxicity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Lee, W. M. (2003) · New England Journal of Medicine · doi:10.1056/nejmra021844 · Cited by 1,594
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Jaeschke, H. (2002) · Toxicological Sciences · doi:10.1093/toxsci/65.2.166 · Cited by 1,304
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
ACETAMINOPHEN-INDUCED HEPATOTOXICITY
James, L. P., Mayeux, P. R., & Hinson, J. A. (2003) · Drug Metabolism and Disposition · doi:10.1124/dmd.31.12.1499 · Cited by 1,033
Engineering vascularized tissue
Jain, R. K., Au, P., Tam, J., Duda, D. G., & Fukumura, D. (2005) · Nature Biotechnology · doi:10.1038/nbt0705-821 · Cited by 808
Modular tissue engineering: engineering biological tissues from the bottom up
Nichol, J. W., & Khademhosseini, A. (2009) · Soft Matter · doi:10.1039/b814285h · Cited by 567
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Cell patterning technologies for organotypic tissue fabrication
Guillotin, B., & Guillemot, F. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.12.008 · Cited by 428
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Ho, C.-T., Lin, R.-Z., Chang, W.-Y., Chang, H.-Y., & Liu, C.-H. (2006) · Lab on a Chip · doi:10.1039/b602036d · Cited by 283
Pluripotent stem cell-derived hepatocyte-like cells
Schwartz, R. E., Fleming, H. E., Khetani, S. R., & Bhatia, S. N. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.01.003 · Cited by 282
Yamada, M., Utoh, R., Ohashi, K., Tatsumi, K., Yamato, M., Okano, T., & Seki, M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.07.068 · Cited by 247
Liver-cell patterning lab chip: mimicking the morphology of liver lobule tissue
Ho, C.-T., Lin, R.-Z., Chen, R.-J., Chin, C.-K., Gong, S.-E., Chang, H.-Y., Peng, H.-L., Hsu, L., Yew, T.-R., Chang, S.-F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50402f · Cited by 230
Elbert, D. L. (2011) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.04.001 · Cited by 191
A gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172
Bile canaliculi formation by aligning rat primary hepatocytes in a microfluidic device
Nakao, Y., Kimura, H., Sakai, Y., & Fujii, T. (2011) · Biomicrofluidics · doi:10.1063/1.3580753 · Cited by 162
Liver tissue engineering in the evaluation of drug safety
Dash, A., Inman, W., Hoffmaster, K., Sevidal, S., Kelly, J., Obach, R. S., Griffith, L. G., & Tannenbaum, S. R. (2009) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425250903160664 · Cited by 158
Li, C. Y., Stevens, K. R., Schwartz, R. E., Alejandro, B. S., Huang, J. H., & Bhatia, S. N. (2014) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0667 · Cited by 132
Kim, Y., & Rajagopalan, P. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015456 · Cited by 125
Materne, E.-M., Tonevitsky, A. G., & Marx, U. (2013) · Lab on a Chip · doi:10.1039/c3lc50240f · Cited by 112
Directing the assembly of spatially organized multicomponent tissues from the bottom up
Liu, J. S., & Gartner, Z. J. (2012) · Trends in Cell Biology · doi:10.1016/j.tcb.2012.09.004 · Cited by 93
Emerging Technologies for Assembly of Microscale Hydrogels
Gurkan, U. A., Tasoglu, S., Kavaz, D., Demirel, M. C., & Demirci, U. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200011 · Cited by 92
“Artificial micro organs”—a microfluidic device for dielectrophoretic assembly of liver sinusoids
Schütte, J., Hagmeyer, B., Holzner, F., Kubon, M., Werner, S., Freudigmann, C., Benz, K., Böttger, J., Gebhardt, R., Becker, H., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9517-7 · Cited by 87
Nolan, C. M., Sandblom, R. E., Thummel, K. E., Slattery, J. T., & Nelson, S. D. (1994) · CHEST Journal · doi:10.1378/chest.105.2.408 · Cited by 86
Puttaswamy, S. V., Sivashankar, S., Chen, R., Chin, C., Chang, H., & Liu, C. H. (2010) · Biotechnology Journal · doi:10.1002/biot.201000194 · Cited by 82
Purpose-driven biomaterials research in liver-tissue engineering
Ananthanarayanan, A., Narmada, B. C., Mo, X., McMillian, M., & Yu, H. (2010) · Trends in biotechnology · doi:10.1016/j.tibtech.2010.10.006 · Cited by 64
Gauvin, R., & Khademhosseini, A. (2011) · ACS Nano · doi:10.1021/nn201826d · Cited by 63
Liu, W., Wang, J.-C., & Wang, J. (2015) · Lab on a Chip · doi:10.1039/c4lc01242a · Cited by 59
Self-citationGriffith, L. G., Wells, A., & Stolz, D. B. (2014) · Hepatology · doi:10.1002/hep.27150 · Cited by 52
Li, L., Ren, L. M., Liu, W., Wang, J., Wang, Y., Tu, Q., Xu, J., Liu, R., Zhang, Y., Yuan, M., et al. (2012) · Analytical Chemistry · doi:10.1021/ac3013708 · Cited by 52
Self-citationThe effect of probenecid on paracetamol metabolism and pharmacokinetics
Kamali, F. (1993) · European Journal of Clinical Pharmacology · doi:10.1007/bf00315313 · Cited by 43
Reduced and oxidized glutathione contents in adult rat hepatocytes under various culture conditions
Mertens, K., Rogiers, V., Sonck, W., & Vercruysse, A. (1991) · Cell Biology and Toxicology · doi:10.1007/bf00122825 · Cited by 14
Cited by
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Self-citationApplication of microfluidic chip technology in pharmaceutical analysis: A review
Cui, P., & Wang, S. (2019) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2018.12.001 · Cited by 390
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Lu, S., Cuzzucoli, F., Jiang, J., Liang, L.-G., Wang, Y., Kong, M., Zhao, X., Cui, W., Li, J., & Wang, S. (2018) · Lab on a Chip · doi:10.1039/c8lc00852c · Cited by 144
Drug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
“[65] developed a microfluidic device that mimics the hepatic lobular-like structure.”
Metadata
- Authors
- Ma, C., Zhao, L., Zhou, E.-M., Xu, J., Shen, S., & Wang, J.
- Affiliations
- Northwest A&F University (CN)
- Corresponding author
- Wang, Jinyi
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-20
- Volume
- 88
- Issue
- 3
- Pages
- 1719-1727
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2235700348
- Cited by
- 145
- References
- 39
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 8 · 2023: 15 · 2022: 17 · 2021: 13 · 2020: 11 · 2019: 24 · 2018: 14 · 2017: 11 · 2016: 10
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Ministry of Education of the People's Republic of China (Z109021303)
- National Natural Science Foundation of China (21175107, 21375106)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- microfluidics, CYP1A1/2, UGT, drug metabolism, drug-drug interactions, adverse drug reactions, drug-induced liver injury, enzyme induction and inhibition, toxicology
- MeSH terms
- Acetaminophen, Drug Evaluation, Preclinical, Humans, Isoniazid, Rifampin, Hepatocytes, Tissue Engineering, Biomimetic Materials, Microfluidic Analytical Techniques, Chemical and Drug Induced Liver Injury, Hep G2 Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.