Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
We report a new online capillary isoelectric focusing-mass spectrometry (CIEF-MS) method for monoclonal antibody (mAb) charge variant analysis using an electrokinetically pumped sheath-flow nanospray ion source and a time-of-flight MS with pressure-assisted chemical mobilization. To develop a successful, reliable CIEF-MS method for mAb, we have selected and optimized many critical, interrelating reagents and parameters that include (1) MS-friendly anolyte and catholyte; (2) a glycerol enhanced sample mixture that reduced non-CIEF electrophoretic mobility and band broadening; (3) ampholyte selected for balancing resolution and MS sensitivity; (4) sheath liquid composition optimized for efficient focusing, mobilization, and electrospray ionization; (5) judiciously selected CIEF running parameters including injection amount, field strength, and applied pressure. The fundamental premise of CIEF was well maintained as verified by the linear correlation (R2 = 0.99) between pI values and migration time using a mixture of pI markers. In addition, the charge variant profiles of trastuzumab, bevacizumab, infliximab, and cetuximab, obtained using this CIEF-MS method, were corroborated by imaged CIEF-UV (iCIEF-UV) analyses. The relative standard deviations (RSD) of absolute migration time of pI markers were all less than 5% (n = 4). Triplicate analyses of bevacizumab showed RSD less than 1% for relative migration time to an internal standard and RSD of 7% for absolute MS peak area. Moreover, the antibody charge variants were characterized using the online intact MS data. To the best of our knowledge, this is the first time that direct online MS detection and characterization were achieved for mAb charge variants resolved by CIEF as indicated by a well-established linear pH gradient and correlated CIEF-UV charge variant profiles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“cIEF-MS with a sheath-liquid interface has been used for the analysis of monoclonal antibodies, with Dai et al. reporting the separation of intact monoclonal antibody92. Resolving intact charge variant peaks is a noted challenge, but using this approach, nine charge variants were resolved.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [92]
Citations
Cites
The therapeutic monoclonal antibody market
Ecker, D. M., Jones, S. D., & Levine, H. L. (2015) · mAbs · doi:10.4161/19420862.2015.989042 · Cited by 1,286
Heterogeneity of Monoclonal Antibodies
Liu, H., Gaza-Bulseco, G., Faldu, D., Chumsae, C., & Sun, J. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21180 · Cited by 481
Adaptation of the equipment for high-performance electrophoresis to isoelectric focusing
Hjertén, S., & Zhu, M.-D. (1985) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90512-0 · Cited by 437
Physicochemical characterization of Remsima®
Jung, S. K., Lee, K. H., Jeon, J. W., Lee, J. W., Kwon, B. O., Kim, Y. J., Bae, J. S., Kim, D.-I., Lee, S. Y., & Chang, S. J. (2014) · mAbs · doi:10.4161/mabs.32221 · Cited by 330
Chromatographic analysis of the acidic and basic species of recombinant monoclonal antibodies
Du, Y., Walsh, A., Ehrick, R., Xu, W., May, K., & Liu, H. (2012) · mAbs · doi:10.4161/mabs.21328 · Cited by 291
Biosimilar, Biobetter, and Next Generation Antibody Characterization by Mass Spectrometry
Beck, A., Sanglier-Cianférani, S., & Van Dorsselaer, A. (2012) · Analytical Chemistry · doi:10.1021/ac3002885 · Cited by 247
Site-specific covalent modification of monoclonal antibodies: in vitro and in vivo evaluations.
Rodwell, J. D., Alvarez, V. L., Lee, C., Lopes, A. D., Goers, J. W., King, H. D., Powsner, H. J., & McKearn, T. J. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.8.2632 · Cited by 246
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Ultrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Ayoub, D., Jabs, W., Resemann, A., Evers, W., Evans, C., Main, L., Baessmann, C., Wagner-Rousset, E., Suckau, D., & Beck, A. (2013) · mAbs · doi:10.4161/mabs.25423 · Cited by 184
Research works printed but not linked: 1
- Michels, 2011, BioProcess Int., 9, 48
Cited by
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Advances in capillary electrophoresis for the life sciences
Toraño, J. S., Ramautar, R., & de Jong, G. J. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.04.020 · Cited by 141
“after the CIEF separation and different interfaces were optimized [37].”
MethodRecent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Recent advances (2019–2021) of capillary electrophoresis‐mass spectrometry for multilevel proteomics
Chen, D., McCool, E. N., Yang, Z., Shen, X., Lubeckyj, R. A., Xu, T., Wang, Q., & Sun, L. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21714 · Cited by 106
Füssl, F., Trappe, A., Carillo, S., Jakes, C., & Bones, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00185 · Cited by 95
Kaur, H., Beckman, J., Zhang, Y., Li, Z. J., Szigeti, M., & Guttman, A. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116407 · Cited by 85
Self-citationŠtěpánová, S., & Kašička, V. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339447 · Cited by 81
Mack, S., Arnold, D. W., Bogdan, G., Bousse, L. J., Danan, L. M., Dolník, V., Ducusin, M., Gwerder, E., Herring, C., Jensen, M., et al. (2019) · Electrophoresis · doi:10.1002/elps.201900325 · Cited by 76
Chopda, V., Gyorgypal, A., Yang, O., Singh, R., Ramachnadran, R., Zhang, H., Tsilomelekis, G., Chundawat, S. P. S., & Ierapetritou, M. (2021) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.6765 · Cited by 83
Lechner, A., Giorgetti, J., Gahoual, R., Beck, A., Leize‐Wagner, E., & François, Y. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.05.014 · Cited by 82
“While 479 some very recent articles describing improvement of CZE-ESI-MS or cIEF-ESI-MS applications for mAbs charge var480 iants characterization [67, 103, 104], another recent approach have been developed to reduce BGE impact on CE481 ESI-MS detection.”
BackgroundMethodInfluentialKrebs, F., Zagst, H., Stein, M., Ratih, R., Minkner, R., Olabi, M., Hartung, S., Scheller, C., Lapizco‐Encinas, B. H., van de Griend, C. S., et al. (2023) · Electrophoresis · doi:10.1002/elps.202300158 · Cited by 77
Wang, L., Bo, T., Zhang, Z., Wang, G., Tong, W., & Chen, D. D. Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02175 · Cited by 68
Applications of capillary electrophoresis for biopharmaceutical product characterization
Kumar, R., Guttman, A., & Rathore, A. S. (2022) · ELECTROPHORESIS · doi:10.1002/elps.202100182 · Cited by 58
Recent advances in top‐down proteome sample processing ahead of MS analysis
Nickerson, J. L., Baghalabadi, V., Rajendran, S. R. C. K., Jakubec, P. J., Said, H., McMillen, T. S., Dang, Z., & Doucette, A. A. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21706 · Cited by 55
Höcker, O., Montealegre, C., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1179-3 · Cited by 55
Xu, T., Wang, Q., Wang, Q., & Sun, L. (2024) · Analytical Methods · doi:10.1039/d4ay00651h · Cited by 56
Xu, T., Han, L., & Sun, L. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00975 · Cited by 53
Dadouch, M., Ladner, Y., & Perrin, C. (2021) · Separations · doi:10.3390/separations8010004 · Cited by 53
Coupling imaged capillary isoelectric focusing with mass spectrometry using a nanoliter valve
Montealegre, C., & Neusüß, C. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800013 · Cited by 48
Dai, J., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04396 · Cited by 46
Self-citationAdvances in capillary electrophoresis-mass spectrometry for cell analysis
Zhou, W., Zhang, B., Liu, Y., Wang, C., Sun, W., Li, W., & Chen, Z. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.05.011 · Cited by 47
Maráková, K., Opetová, M., & Tomašovský, R. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300244 · Cited by 45
Xu, T., Shen, X., Yang, Z., Chen, D., Lubeckyj, R. A., McCool, E. N., & Sun, L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03266 · Cited by 43
Xu, T., Han, L., Thompson, A. M. G., & Sun, L. (2021) · Analytical Methods · doi:10.1039/d1ay01556g · Cited by 41
Performance of capillary electrophoresis instruments – State of the art and outlook
Hartung, S., Minkner, R., Olabi, M., & Wätzig, H. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117056 · Cited by 40
A Mini Review on Capillary Isoelectric Focusing-Mass Spectrometry for Top-Down Proteomics
Xu, T., & Sun, L. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.651757 · Cited by 42
“Reducing the Impact of Carrier Ampholytes Carrier ampholytes induce ionization suppression of analytes (Dai et al., 2018), restricting the overall sensitivity of cIEFMS.”
BackgroundMethodInfluentialWu, G., Yu, C., Wang, W., Du, J., Fu, Z., Xu, G., Li, M., & Wang, L. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c05071 · Cited by 35
Schlecht, J., Moritz, B., Kiessig, S., & Neusüß, C. (2022) · Electrophoresis · doi:10.1002/elps.202200170 · Cited by 38
Füssl, F., Criscuolo, A., Cook, K., Scheffler, K., & Bones, J. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00375 · Cited by 39
Goyon, A., François, Y., Colas, O., Beck, A., Veuthey, J., & Guillarme, D. (2018) · Electrophoresis · doi:10.1002/elps.201800131 · Cited by 35
Liu, Z., Valente, J. J., Lin, S., Chennamsetty, N., Qiu, D., & Bolgar, M. S. (2019) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2019.05.023 · Cited by 34
Microfluidic-based electrically driven particle manipulation techniques for biomedical applications
Wang, J., Cui, X., Wang, W., Wang, J., Zhang, Q. W., Guo, X., Liang, Y., Lin, S., Chu, B., & Cui, D. (2025) · RSC Advances · doi:10.1039/d4ra05571c · Cited by 36
He, X. Z., ElNaggar, M., Ostrowski, M. A., Guttman, A., Gentalen, E., & Sperry, J. B. (2022) · Electrophoresis · doi:10.1002/elps.202100295 · Cited by 31
“Attempts to alleviate these and other issues have led to the development of special sprayer designs to reduce sample dilution [16] and 2D setups to decouple the CE and ESI processes [17], as well as cIEF and MS coupling via an electrokinetically pumped sheath-flow nanospray [18].”
BackgroundWu, Z., Wang, H., Wu, J., Huang, Y., Zhao, X., Nguyen, J. B., Rosconi, M. P., Pyles, E. A., Qiu, H., & Li, N. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.115147 · Cited by 29
Xu, T., Zhang, F., Chen, D., Sun, L., Tomazela, D. M., & Fayadat‐Dilman, L. (2023) · mAbs · doi:10.1080/19420862.2023.2229102 · Cited by 30
Schlecht, J., Jooß, K., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1157-9 · Cited by 29
Wang, L., & Chen, D. D. Y. (2019) · Electrophoresis · doi:10.1002/elps.201900195 · Cited by 26
Ostrowski, M. A., Mack, S., Niñonuevo, M. R., Yan, J., ElNaggar, M., Gentalen, E., & Michels, D. A. (2022) · Electrophoresis · doi:10.1002/elps.202200165 · Cited by 25
“Separation by capillary formats coupled to MS has been demonstrated [9, 10] but often requires lengthy separation and analysis times.”
Niu, J., Bao, Z., Wei, Z., Li, J. X., Gao, B., Jiang, X., & Li, F. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04883 · Cited by 24
Sixteen capillary electrophoresis applications for viral vaccine analysis
Geurink, L., van Tricht, E., van der Burg, D., Scheppink, G., Pajic, B., Dudink, J., & van de Griend, C. S. (2021) · Electrophoresis · doi:10.1002/elps.202100269 · Cited by 24
Liu, A. P., Yan, Y., Wang, S., & Li, N. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00707 · Cited by 24
Capillary electrophoresis as a sample separation step to mass spectrometry analysis: A primer
Lapizco‐Encinas, B. H., Zhang, Y. V., Gqamana, P. P., Lavická, J., & Foret, F. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117093 · Cited by 29
Self-citationLiu, H., Ren, W., Zong, L., Zhang, J., & Wang, Y. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.10.002 · Cited by 28
“Good separat ion and intact molecular weight can usually be obtained using IEF, cIEF [52, 53], and e specially two-dimensional capillary zone electrophoresis (2D CZE) coupled with a mass spectr ometry detector [54], but it is difficult to collect sufficient material for detailed characteri zat on.”
BackgroundLiquid Plasticine Integrated with Isoelectric Focusing for Miniaturized Protein Analysis
Niu, J., Shi, H., Wei, H., Gao, B., Li, J. X., Xu, F., Li, X., & Li, F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01237 · Cited by 23
Sun, Q., Wang, L., Li, N., & Shi, L. (2021) · Analytical Biochemistry · doi:10.1016/j.ab.2021.114214 · Cited by 22
Zhu, Z., Lies, M., & Silzel, J. W. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338936 · Cited by 22
Apostoł, I., Bondarenko, P. V., Ren, D., Semin, D. J., Wu, C., Zhang, Z., & Goudar, C. T. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.08.001 · Cited by 22
Chen, H., Qiu, D., Shi, J., Wang, N., Li, M., Wu, Y. H., Tian, Y., Bu, X., Liu, Q., Jiang, Y., et al. (2023) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.3c00235 · Cited by 22
Zhu, G., Sadeghi, S. A., Mahmoudi, M., & Sun, L. (2024) · Chemical Communications · doi:10.1039/d4cc02666g · Cited by 23
Capillary Electrophoresis–Mass Spectrometry for Top-Down Proteomics
Wang, Q., Wang, Q., Zhu, G., & Sun, L. (2025) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071124-092242 · Cited by 24
Liu, R., Cheddah, S., Liu, S., Liu, Y., Wang, Y., & Yan, C. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.10.036 · Cited by 20
Thread-based isoelectric focusing coupled with desorption electrospray ionization mass spectrometry
Chen, L., Cabot, J. M., Rodríguez, E. S., Ghiasvand, A., Innis, P. C., & Paull, B. (2020) · The Analyst · doi:10.1039/d0an01344g · Cited by 20
Analytical tools for the characterization of deamidation in monoclonal antibodies
Spanov, B., Govorukhina, N. I., van de Merbel, N. C., & Bischoff, R. (2021) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2021.100025 · Cited by 22
Kwok, T., Chan, S. L., Courtney, M., Zhou, M., Huang, T., Bo, T., Li, V. C., & Chen, T. (2023) · Analytical Biochemistry · doi:10.1016/j.ab.2023.115312 · Cited by 19
Li, G., Li, H.-G., Dong, F., Bi, Y., Zhang, Q., Kong, F., Liu, X., Saud, S., Xiao, H., Luo, F., et al. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.03.014 · Cited by 19
Zhang, X., Wu, G., Du, M., Bo, T., Chen, T., & Huang, T. (2024) · Electrophoresis · doi:10.1002/elps.202400083 · Cited by 18
“Conventional cIEF with single-point detection has been coupled to MS for protein characterization [30–33], but cIEF–MS has the disadvantages of low throughput and cumbersome operation due to a tedious chemical mobilization process that disrupts the pH gradient disruption with unsatisfactory…”
Zhang, H., Lou, C., Li, J., & Kang, J. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461215 · Cited by 18
Ouyang, Y., Han, X., Xia, Q., Chen, J., Velagapudi, S., Xia, K., Zhang, Z., & Linhardt, R. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03500 · Cited by 18
Self-citationCao, M., Mel, N. D., Wang, J., Parthemore, C., Jiao, Y., Chen, W., Lin, S., Liu, D., Kilby, G. W., & Chen, X. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.09.006 · Cited by 17
Han, M., Wang, Y., Cook, K. D., Bala, N. S., Soto, M., Rock, D. A., Pearson, J. T., & Rock, B. M. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00149 · Cited by 18
Process- and Product-Related Foulants in Virus Filtration
Isu, S., Qian, X., Zydney, A. L., & Wickramasinghe, S. R. (2022) · Bioengineering · doi:10.3390/bioengineering9040155 · Cited by 21
“Acidic and basic variants of glycoproteins such as mAbs and Fc-fusion proteins can have different glycan profiles [78,79].”
BackgroundBo, T., Yang, F., Yan, B., Michels, D., Huang, T.-M., & Pawliszyn, J. (2025) · Trends in Analytical Chemistry (TrAC) · doi:10.1016/j.trac.2025.118212 · Cited by 15
CE-MS for Proteomics and Intact Protein Analysis
Kuzyk, V., Somsen, G. W., & Haselberg, R. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-77252-9_4 · Cited by 15
Schairer, J., Höchsmann, A., Bauer, B., Höfer, V., Römer, J., & Neusüß, C. (2025) · mAbs · doi:10.1080/19420862.2025.2537116 · Cited by 14
“19,20,72,83 All these approaches provide quite high mass spectra quality, even though separation is always impaired in the mobilization step.”
Krieg, D., Winter, G., & Svilenov, H. L. (2022) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2022.05.014 · Cited by 17
Naghdi, E., Reinau, M. E., Krogh, T. N., & Neusüß, C. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c02441 · Cited by 14
Urasaki, Y., Fiscus, R. R., & Le, T. T. (2018) · Scientific Reports · doi:10.1038/s41598-018-28335-8 · Cited by 13
Li, M., Zhao, X., Shen, D., Wu, G., Wang, W., Yu, C., Sausen, J., Xu, H., & Wang, L. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2022.463560 · Cited by 13
Wu, G., Du, J., Yu, C., Fu, Z., Zhang, X., Wang, L., & Wang, J. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342349 · Cited by 10
Liu, R., Cheddah, S., Xu, X., Wang, W., Wang, Y., & Yan, C. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.06.013 · Cited by 12
Nagy, C., Andrási, M., Hamidli, N., Gyémánt, G., & Gáspár, A. (2021) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2021.100024 · Cited by 12
Liu, R., Pan, H., Zheng, Y., Hu, J., Cheddah, S., Wang, W., Wang, Y., & Yan, C. (2019) · Electrophoresis · doi:10.1002/elps.201900125 · Cited by 11
Sreenivasan, S., Kumar, D., Malani, H., & Rathore, A. S. (2019) · Analytical Biochemistry · doi:10.1016/j.ab.2019.113513 · Cited by 13
van der Zon, A. A. M., Höchsmann, A., Bos, T. S., Neusüß, C., Somsen, G. W., Jooß, K., Haselberg, R., & Gargano, A. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343287 · Cited by 10
“However, the coupling of cIEF to MS is considered more complex, as ampholytes are often present in high concentrations and cause substantial MS ionization suppression [11,21].”
Kerr, C. M., Schneider, O. L., Tichy, S. E., Huge, B. J., & Champion, M. M. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05010 · Cited by 11
Chan, S. L., Kwok, T., Xu, N., Bo, T., & Huang, T. (2025) · Analytical Biochemistry · doi:10.1016/j.ab.2025.115765 · Cited by 10
Bwanali, L., & Holland, L. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02576 · Cited by 10
Trappe, A., Füssl, F., Millán‐Martín, S., Ronan, R., Zaborowska, I., & Bones, J. (2022) · Journal of Chromatography B · doi:10.1016/j.jchromb.2022.123186 · Cited by 10
Gilardoni, E., & Regazzoni, L. (2022) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2022.100034 · Cited by 9
Blue, L. E., Guan, X., Joubert, M. K., Kuhns, S. T., Moore, S., Semin, D. J., Wikström, M., Wypych, J., & Goudar, C. T. (2022) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2022.102800 · Cited by 9
Cageling, R., Carillo, S., Boumeester, A. J., Lubbers-Geuijen, K., Bones, J., Jooß, K., & Somsen, G. W. (2024) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2024.116301 · Cited by 8
Liu, Q., Hong, J.-Y., Zhang, Y., Wang, Q., Xia, Q., Knierman, M. D., Lau, J., Dayaratna, C., Negron, B., Nanda, H., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-70914-5 · Cited by 10
Self-citationIsolation and characterization of charge variants of infliximab biosimilar HS626
Yuan, J., Gao, D., Hu, F., Shi, Y., Wu, Z.-H., Hu, C., Huang, X., Fang, W., Zhang, H., & Wang, H. (2020) · Journal of Chromatography B · doi:10.1016/j.jchromb.2020.122485 · Cited by 9
Hitting the sweet spot with capillary electrophoresis: advances in N-glycomics and glycoproteomics
Makrydaki, E., Kotidis, P., Polizzi, K. M., & Kontoravdi, C. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.07.013 · Cited by 8
Cruzado‐Park, I. D. (2020) · Electrophoresis · doi:10.1002/elps.201900449 · Cited by 7
Dai, J., & Ji, C. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341360 · Cited by 7
Self-citationBeloborodov, S. S., Schneider, B. B., Oleschuk, R. D., & Blanc, J. C. Y. L. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00060 · Cited by 6
Ayon, N. J. (2025) · AppliedChem · doi:10.3390/appliedchem5040035 · Cited by 7
“…Dai et al. is notable due to their comprehensive method development and optimization of numerous parameters, including composition of anolyte, catholyte, sample mixture, sheath liquid, and cIEF running parameters such as injection amount, field strength, and applied pressure [246] for nMS analysis.”
Kwok, T., Chan, S. L., Zhou, M., Chen, T., Xu, N., Li, V. C., Huang, T., & Bo, T. (2025) · Green Analytical Chemistry · doi:10.1016/j.greeac.2025.100204 · Cited by 5
Patrie, S. M., & Cline, E. N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-818607-7.00017-7 · Cited by 5
Candreva, J., Esterman, A. L., Ge, D., Patel, P., Flagg, S. C., Das, T. K., & Li, X. (2022) · Electrophoresis · doi:10.1002/elps.202200026 · Cited by 5
Kaya, S. I., Çetinkaya, A., Çağlayan, M. G., & Özkan, S. A. (2021) · Electrophoresis · doi:10.1002/elps.202100193 · Cited by 5
Dai, J., Xia, Q., & Ji, C. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2325-1_6 · Cited by 5
Self-citationTie, C., Liu, L., Feng, T., Sa, R., Xia, Q., Liang, H., & Mao, Y. (2020) · Journal of Proteomics · doi:10.1016/j.jprot.2020.103676 · Cited by 5
Self-citationDiehm, J., Witting, L., Kirschhöfer, F., Brenner-Weiß, G., & Franzreb, M. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-05023-9 · Cited by 2
“…is promising [7], as it is considered one of the most powerful techniques [8] capable of detecting a wide range of quality attributes, including glycosylation patterns [9, 10], charge variants [11, 12], aggregates [13, 14], as well as process-related impurities such as host cell proteins [15–17].”
Dhulipala, G., Broszeit, A., Lu, K., Palackal, N. T., & Pyles, E. A. (2024) · mAbs · doi:10.1080/19420862.2024.2429414 · Cited by 4
New analytical challenges in characterization of antibody-drug conjugates
Ricci, E. M., Dainese, E., Laurenzi, V. D., Lovato, G., Sala, G., Locatelli, M., & Perrucci, M. (2025) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2025.100260 · Cited by 6
Biophysical Analysis of Therapeutic Antibodies in the Early Development Pipeline
Willis, L. F., Kapur, N., Radford, S. E., & Brockwell, D. J. (2024) · Biologics · doi:10.2147/btt.s486345 · Cited by 8
Alissa, M., Alghamdi, A. A., Alghamdi, S. A., Alshehri, M. A., Aloraini, G. S., Albelasi, A., & Alshammari, M. S. (2025) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2025.144881 · Cited by 7
HPLC- and CE-based methods for the characterization of therapeutic glycoproteins
Butré, C. I., & Delobel, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00014-7 · Cited by 4
Metadata
- Authors
- Dai, J., Lamp, J., Xia, Q., & Zhang, Y.
- Affiliations
- Bristol-Myers Squibb (United States) (US)
- CMP Scientific, Corporation , 760 Parkside Avenue, Suite 211 , , ,
- Corresponding author
- Dai, Jun
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-12-22
- Volume
- 90
- Issue
- 3
- Pages
- 2246-2254
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2777107256
- Cited by
- 123
- References
- 49
- Citations by year
- 2026: 3 · 2025: 12 · 2024: 13 · 2023: 13 · 2022: 19 · 2021: 24 · 2020: 10 · 2019: 17 · 2018: 12
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Analytical Chemistry (publishedVersion, other-oa)
- PubMed (publishedVersion)
- Funders
- Bristol-Myers Squibb
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Keywords
- isoelectric focusing, on-line mass spectrometry, trastuzumab, bevacizumab, infliximab, cetuximab, isoelectric point determination
- MeSH terms
- Antibodies, Monoclonal, Isoelectric Focusing, Reproducibility of Results, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.