CoChat

Fabrication of a Biodegradable Implant with Tunable Characteristics for Bone Implant Applications

The DOI matches its Crossref record; 47 of the 48 references it cites were found in a registry or an index.

Abstract

Biodegradable polymers are appealing material for the manufacturing of surgical implants as such implants break down in vivo, negating the need for a subsequent operation for removal. Many biocompatible polymers produce acidic breakdown products that can lead to localized inflammation and osteolysis. This study assesses the feasibility of fabricating implants out of poly(propylene carbonate) (PPC)–starch that degrades into CO 2 and water. The basic compression modulus of PPC–starch (1:1 w/w) is 34 MPa; however, the addition of glycerol (1% w/w) and water as plasticizers doubles this value and enhances the surface wettability. The bioactivity and stiffness of PPC–starch blends is increased by the addition of bioglass microparticles (10% w/w) as shown by in vitro osteoblast differentiation assay and mechanical testing. MicroCT analysis confirms that the bioglass microparticles are evenly distributed throughout biomaterial. PPC–starch–bioglass was tested in vivo in two animal models. A murine subcutaneous pellet degradation assay demonstrates that the PPC–starch–bioglass blend’s volume fraction loss is 46% after 6 months postsurgery, while it is 27% for poly(lactic acid). In a rat knee implantation model, PPC–starch–bioglass screws inserted into the distal femur show osseointegration with no localized adverse effects after 3 and 12 weeks. These data support the further development of PPC–starch–bioglass as a medical biomaterial.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.biomac.7b00078

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 47 references

Research works printed but not linked: 1

  1. Wang Y., 2011, China Med. J., 124, 2361

Cited by

See all 57

Metadata

Authors
Manavitehrani, I., Fathi, A., Wang, Y., Maitz, P. K., Mirmohseni, F., Cheng, T. L., Peacock, L., Little, D. G., Schindeler, A., & Dehghani, F.
Affiliations
  • The University of Sydney (AU)
  • Children's Hospital at Westmead (AU)
Corresponding author
Dehghani, Fariba
Venue
Biomacromolecules
Published
2017-05-23
Volume
18
Issue
6
Pages
1736-1746
ISSN
  • 1525-7797 (ISSN-L)
  • 1526-4602
OpenAlex
W2619049879
Cited by
55
References
48
Citations by year
2026: 4 · 2025: 3 · 2024: 7 · 2023: 6 · 2022: 6 · 2021: 7 · 2020: 4 · 2019: 7 · 2018: 8 · 2017: 3
FWCI
2.71
Type
journal article
Language
en
Open access
closed
Locations
  • Biomacromolecules (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • University of Sydney
  • Department of Education and Training
  • Australian Research Council
  • Global Human Capital Pty Ltd
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
Keywords
biodegradable implants, poly(propylene carbonate), starch, glycerol plasticizer, bone screws, osseointegration, in vivo degradation, osteogenic differentiation, compressive modulus, wettability, distal femur
MeSH terms
Bone-Implant Interface, Animals, Biocompatible Materials, Carbon Dioxide, Cell Differentiation, Ceramics, Female, Femur, Glycerol, Humans, Hydrolysis, Male, Mice, Inbred BALB C, Osteoblasts, Polypropylenes, Starch, Water, Wettability, Absorbable Implants, Cell Line, Tumor, Mice, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fabrication of a Biodegradable Implant with Tunable Characteristics for Bone Implant Applications. https://app.cochat.ai/papers/10.1021/acs.biomac.7b00078
The paper
Manavitehrani, I., Fathi, A., Wang, Y., Maitz, P. K., Mirmohseni, F., Cheng, T. L., Peacock, L., Little, D. G., Schindeler, A., & Dehghani, F. (2017). Fabrication of a Biodegradable Implant with Tunable Characteristics for Bone Implant Applications. Biomacromolecules. https://doi.org/10.1021/acs.biomac.7b00078

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.