CoChat

Assessing the Effectiveness of Point-of-Use Residential Drinking Water Filters for Perfluoroalkyl Substances (PFASs)

Open access
Herkert, Nicholas J., Merrill, John, Peters, Cara, Bollinger, David, Zhang, Sharon, Hoffman, Kate, Ferguson, P. Lee, Knappe, Detlef R. U., Stapleton, Heather M. · 2020 · Environmental Science & Technology Letters
Cited by 125

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

Abstract Per- and polyfluoroalkyl substances (PFASs) have come under increased scrutiny due to concerns about their potential toxicity and prevalence in the environment, particularly drinking water. PFASs are difficult to remove in full-scale water treatment systems because of their physicochemical properties. Here we evaluated the effectiveness of point-of-use (POU) and point-of-entry (POE) residential drinking water filters in removing a suite of three perfluoroalkyl sulfonic acids, seven perfluoroalkyl carboxylic acids, and six per- and polyfluoroalkyl ether acids in homes in central (n = 61) and southeastern (n = 12) North Carolina. POU systems included countertop and pitcher filters, faucet-mounted filters, activated carbon block refrigerator filters, activated carbon block under-sink filters, under-sink dual-stage filters, and under-sink reverse osmosis filters. All under-sink dual-stage and reverse osmosis filters tested showed near complete removal for all PFASs evaluated. In contrast, all other filters containing activated carbon exhibited variable PFAS removal. In these filters, PFAS removal efficiency was dependent on chain length, with long-chain PFASs (∼60–70% removal) being more efficiently removed than short-chain PFASs (∼40% removal). A few whole-house activated carbon POE systems (n = 8) were also evaluated; however, results were variable, and in some cases (four of eight systems), increased PFAS levels were observed in the filtered water.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.estlett.0c00004

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 125

Metadata

Authors
Herkert, N. J., Merrill, J., Peters, C., Bollinger, D., Zhang, S., Hoffman, K., Ferguson, P. L., Knappe, D. R. U., & Stapleton, H. M.
Venue
Environmental Science & Technology Letters
Published
2020-02-05
Volume
7
Issue
3
Pages
178-184
ISSN
2328-8930 (ISSN-L)
OpenAlex
W3004437885
Cited by
125
References
36
FWCI
5.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing the Effectiveness of Point-of-Use Residential Drinking Water Filters for Perfluoroalkyl Substances (PFASs). https://app.cochat.ai/papers/10.1021/acs.estlett.0c00004
The paper
Herkert, N. J., Merrill, J., Peters, C., Bollinger, D., Zhang, S., Hoffman, K., Ferguson, P. L., Knappe, D. R. U., & Stapleton, H. M. (2020). Assessing the Effectiveness of Point-of-Use Residential Drinking Water Filters for Perfluoroalkyl Substances (PFASs). Environmental Science & Technology Letters. https://doi.org/10.1021/acs.estlett.0c00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.