Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Temperature-Responsive Ionic Conductive Hydrogel for Strain and Temperature Sensors

Pang, Qian, Hu, Hongtao, Zhang, Haiqi, Qiao, Bianbian, Ma, Lie·2022·ACS Applied Materials & Interfaces

Abstract

Flexible wearable devices have achieved remarkable applications in health monitoring because of the advantages of multisignal collecting and real-time wireless transmission of information. However, the integration of bulky sensing elements and rigid metal circuit components in traditional wearable devices may lead to a mechanical and signal-conducting mismatch between wearable devices and biological tissues, thus restricting their wide applications in the human body. The excellent mechanical properties, conductivity, and high tissue resemblance of conductive hydrogel contribute to its application in flexible electronic sensors to monitor human health. In this work, a dual-network, temperature-responsive ionic conductive hydrogel with excellent stretchability, fast temperature responsiveness, and good conductivity was developed by introducing a polyvinylpyrrolidone (PVP)/ tannic acid (TA)/ Fe 3+ cross-linked network into the N, N -methylene diacrylamide (MBAA) cross-linked poly( N -isopropylacrylamide- co -acrylamide) (P(NIPAAm- co -AM)) network. Furthermore, the introduction of the PVP/TA/Fe 3+ cross-linked network endowed the hydrogel with excellent stretchability and conductivity. By adjusting the molar ratio of TA and Fe 3+ to 3:5, a hydrogel with a maximal stretching ratio of 720% and sensitive strain response (GF = 3.61) was achieved, showing a promising application in wearable strain sensors to monitor both large and fine human motions. Moreover, by introducing PNIPAAm with a lower critical solution temperature (LCST), the hydrogel may be used to monitor the environmental temperature through the temperature–conductivity responsiveness, which can be applied as a wearable temperature sensor to detect fever or tissue hyperthermia in the human body.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.2c06952

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Pang, Q., Hu, H., Zhang, H., Qiao, B., & Ma, L.
Venue
ACS Applied Materials & Interfaces
Published
2022-06-03
Volume
14
Issue
23
Pages
26536-26547
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W4282044719
Cited by
242
References
6
FWCI
13.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.