CoChat

Simple Approach to High-Performance Stretchable Heaters Based on Kirigami Patterning of Conductive Paper for Wearable Thermotherapy Applications

Jang, Nam-Su, Kim, Kang-Hyun, Ha, Sung-Hun, Jung, Soo-Ho, Lee, Hye Moon, Kim, Jong-Man · 2017 · ACS Applied Materials & Interfaces

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Recent efforts to develop stretchable resistive heaters open up the possibility for their use in wearable thermotherapy applications. Such heaters should have high electrothermal performance and stability to be used practically, and the fabrication must be simple, economic, reproducible, and scalable. Here we present a simple yet highly efficient way of producing high-performance stretchable heaters, which is based on a facile kirigami pattering (the art of cutting and folding paper) of a highly conductive paper for practical wearable thermotherapy. The resulting kirigami heater exhibits high heating performance at low voltage (>40 °C at 1.2 V) and fast thermal response (<60 s). The simple kirigami patterning approach enables the heater to be extremely stretchable (>400%) while stably retaining its excellent performance. Furthermore, the heater shows the uniform spatial distribution of heat over the whole heating area and is highly durable (1000 cycles at 300% strain). The heater attached to curvilinear body parts shows stable heating performance even under large motions while maintaining intimate conformal contact with the skin thanks to the high stretchability and sufficient restoring force. The usability of the heater as a wearable thermotherapy device is demonstrated by increased blood flow at the wrist during operation.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsami.7b03474

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 159

Metadata

Authors
Jang, N.-S., Kim, K.-H., Ha, S.-H., Jung, S.-H., Lee, H. M., & Kim, J.-M.
Affiliations
Korea Institute of Materials Science (KR)
Corresponding author
  • Lee, Hye Moon
  • Kim, Jong-Man
Venue
ACS Applied Materials & Interfaces
Published
2017-06-01
Volume
9
Issue
23
Pages
19612-19621
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2617540989
Cited by
159
References
29
Citations by year
2026: 9 · 2025: 14 · 2024: 18 · 2023: 14 · 2022: 21 · 2021: 29 · 2020: 28 · 2019: 18 · 2018: 7 · 2017: 1
FWCI
6.64
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Applied Materials & Interfaces (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Research Foundation of Korea (No. 2015R1A2A2A01004038)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
stretchable heaters, conductive paper, electrothermal heating, wearable electronics, thermal response
MeSH terms
Wearable Electronic Devices, Hot Temperature, Heating, Hyperthermia, Induced

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.