Hygroscopic Auxetic On-Skin Sensors for Easy-to-Handle Repeated Daily Use
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Despite the advance of on-skin sensors over the last decade, a sensor that solves simultaneously the critical issues for using in everyday life, such as stable performance in various environments, use over a long period of time, and repeated use by easy handling, has not yet been achieved. Here, we introduce an auxetic hygroscopic sensor that simultaneously meets all of the conditions. The auxetic structure with a negative Poisson's ratio matches with deformation of the skin in ankles; hence, a conformal contact between the sensor and the skin could be maintained during repeated movements. Sweat was absorbed in the auxetic electrode made of a hydrogel pattern coated with Ag nanowires and evaporated quickly; such hygroscopic characteristic led to excellent breathability. An electrocardiogram sensor and a haptic device were fabricated according to the proposed design for a sensor electrode. The sensors provide stable detecting performance in various environments, such as exercising, submersion in water, exposure to concentrated salt water, and continuous wearing for long time (7 days). Also, the sensors could be manually attached repeatedly without degrading the performance. This study provides new structural insights for on-skin sensors and presents future research directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationInflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Yu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523
Self-citationKim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Self-citationStretchable E‐Skin Apexcardiogram Sensor
You, I., Kim, B., Park, J., Koh, K., Shin, S., Jung, S., & Jeong, U. (2016) · Advanced Materials · doi:10.1002/adma.201600720 · Cited by 213
Self-citation
Cited by
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Gas-Permeable, Ultrathin, Stretchable Epidermal Electronics with Porous Electrodes
Zhou, W., Yao, S., Wang, H., Du, Q., Ma, Y., & Zhu, Y. (2020) · ACS Nano · doi:10.1021/acsnano.0c00906 · Cited by 300
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
“Then, they integrated the sensor into the fabric and developed a wireless, non-contact headband for EEG monitoring [30].”
Method
Metadata
- Authors
- Kim, H. W., Kim, T. Y., Park, H. K., You, I., Kwak, J., Kim, J. C., Hwang, H., Kim, H. S., & Jeong, U.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-10-15
- Volume
- 10
- Issue
- 46
- Pages
- 40141-40148
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2896332982
- Cited by
- 100
- References
- 10
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hygroscopic Auxetic On-Skin Sensors for Easy-to-Handle Repeated Daily Use. https://app.cochat.ai/papers/10.1021/acsami.8b13857
- The paper
- Kim, H. W., Kim, T. Y., Park, H. K., You, I., Kwak, J., Kim, J. C., Hwang, H., Kim, H. S., & Jeong, U. (2018). Hygroscopic Auxetic On-Skin Sensors for Easy-to-Handle Repeated Daily Use. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b13857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.