Applied body-fluid analysis by wearable devices

Open access
Brasier, Noé, Wang, Joseph, Gao, Wei, Sempionatto, Juliane R., Dincer, Can, Ates, H. Ceren, Güder, Firat, Olenik, Selin, Schauwecker, Ivo, Schaffarczyk, Dietmar, Vayena, Effy, Ritz, Nicole, Weisser, Maja, Mtenga, Sally, Ghaffari, Roozbeh, Rogers, John A., Goldhahn, Jörg·2024·Nature

Abstract

Wearable sensors are a recent paradigm in healthcare, enabling continuous, decentralized, and non- or minimally invasive monitoring of health and disease. Continuous measurements yield information-rich time series of physiological data that are holistic and clinically meaningful. Although most wearable sensors were initially restricted to biophysical measurements, the next generation of wearable devices is now emerging that enable biochemical monitoring of both small and large molecules in a variety of body fluids, such as sweat, breath, saliva, tears and interstitial fluid. Rapidly evolving data analysis and decision-making technologies through artificial intelligence has accelerated the application of wearables around the world. Although recent pilot trials have demonstrated the clinical applicability of these wearable devices, their widespread adoption will require large-scale validation across various conditions, ethical consideration and sociocultural acceptance. Successful translation of wearable devices from laboratory prototypes into clinical tools will further require a comprehensive transitional environment involving all stakeholders. The wearable device platforms must gain acceptance among different user groups, add clinical value for various medical indications, be eligible for reimbursements and contribute to public health initiatives. In this Perspective, we review state-of-the-art wearable devices for body-fluid analysis and their translation into clinical applications, and provide insight into their clinical purpose. A review of wearable devices for body-fluid analysis discusses the strategies, considerations and challenges to achieve their successful clinical translation and how they might contribute to solving some global healthcare challenges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-024-08249-4

Cites

122 of 122 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 122 references

Metadata

Authors
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., Vayena, E., Ritz, N., Weisser, M., Mtenga, S., Ghaffari, R., Rogers, J. A., & Goldhahn, J.
Venue
Nature
Published
2024-12-04
Volume
636
Issue
8041
Pages
57-68
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4405030109
Cited by
298
References
122
FWCI
31.30
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Applied body-fluid analysis by wearable devices. https://app.cochat.ai/papers/10.1038/s41586-024-08249-4
The paper
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., Vayena, E., Ritz, N., Weisser, M., Mtenga, S., Ghaffari, R., Rogers, J. A., & Goldhahn, J. (2024). Applied body-fluid analysis by wearable devices. Nature. https://doi.org/10.1038/s41586-024-08249-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.