Artificial Intelligence-Enabled Caregiving Walking Stick Powered by Ultra-Low-Frequency Human Motion
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The increasing population of the elderly and motion-impaired people brings a huge challenge to our social system. However, the walking stick as their essential tool has rarely been investigated into its potential capabilities beyond basic physical support, such as activity monitoring, tracing, and accident alert. Here, we report a walking stick powered by ultra-low-frequency human motion and equipped with deep-learning-enabled advanced sensing features to provide a healthcare-monitoring platform for motion-impaired users. A linear-to-rotary structure is designed to achieve highly efficient energy harvesting from the linear motion of a walking stick with ultralow frequency. Besides, two kinds of self-powered triboelectric sensors are proposed and integrated to extract the motion features of the walking stick. Augmented sensing functionalities with high accuracies have been enabled by deep-learning-based data analysis, including identity recognition, disability evaluation, and motion status distinguishing. Furthermore, a self-sustainable Internet of Things (IoT) system with global positioning system tracing and environmental temperature and humidity amenity sensing functions is obtained. Combined with the aforementioned functionalities, this walking stick is demonstrated in various usage scenarios as a caregiver for real-time well-being status and activity monitoring. The caregiving walking stick shows the potential of being an intelligent aid for motion-impaired users to help them live life with adequate autonomy and safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008
Energy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888
Wireless battery-free wearable sweat sensor powered by human motion
Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W. (2020) · Science Advances · doi:10.1126/sciadv.aay9842 · Cited by 652
Sustainably powering wearable electronics solely by biomechanical energy
Wang, J., Li, S., Yi, F., Zi, Y., Lin, J., Wang, X., Xu, Y., & Wang, Z. L. (2016) · Nature Communications · doi:10.1038/ncomms12744 · Cited by 648
Electromagnetic generator for harvesting energy from human motion
Saha, C. R., O’Donnell, T., Wang, N., & McCloskey, P. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.03.008 · Cited by 608
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Pu, X., Hu, W., & Wang, Z. L. (2018) · Small · doi:10.1002/smll.201702817 · Cited by 378
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Luo, A., Zhang, Y., Dai, X., Wang, Y., Xu, W., Lu, Y., Wang, M., Fan, K., & Wang, F. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115762 · Cited by 140
Self-citation
Cited by
Sun, Z., Zhu, M., Shan, X., & Lee, C. (2022) · Nature Communications · doi:10.1038/s41467-022-32745-8 · Cited by 532
Self-citationZhang, Z., Wen, F., Sun, Z., Guo, X., He, T., & Lee, C. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100228 · Cited by 464
Self-citationZhang, Q., Jin, T., Cai, J., Xu, L., He, T., Wang, T., Tian, Y., Li, L., Peng, Y., & Lee, C. (2022) · Advanced Science · doi:10.1002/advs.202103694 · Cited by 386
Self-citationYang, Y., Guo, X., Zhu, M., Sun, Z., Zhang, Z., He, T., & Lee, C. (2023) · Advanced Energy Materials · doi:10.1002/aenm.202203040 · Cited by 337
Self-citationWang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Self-citationShi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Huang, M., Zhu, M., Feng, X., Zhang, Z., Tang, T., Guo, X., Chen, T., Liu, H., Sun, L., & Lee, C. (2023) · ACS Nano · doi:10.1021/acsnano.2c11366 · Cited by 90
Self-citation
Metadata
- Authors
- Guo, X., He, T., Zhang, Z., Luo, A., Wang, F., Ng, E. J., Zhu, Y., Liu, H., & Lee, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-07-26
- Volume
- 15
- Issue
- 12
- Pages
- 19054-19069
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3183244081
- Cited by
- 157
- References
- 11
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.