CoChat

Impact of Surface Polyethylene Glycol (PEG) Density on Biodegradable Nanoparticle Transport in Mucus ex Vivo and Distribution in Vivo

Open access

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Abstract

Achieving sustained drug delivery to mucosal surfaces is a major challenge due to the presence of the protective mucus layer that serves to trap and rapidly remove foreign particulates. Nanoparticles engineered to rapidly penetrate mucosal barriers (mucus-penetrating particles, "MPP") have shown promise for improving drug distribution, retention and efficacy at mucosal surfaces. MPP are densely coated with polyethylene glycol (PEG), which shields the nanoparticle core from adhesive interactions with mucus. However, the PEG density required to impart the "stealth" properties to nanoparticles in mucus, and thus, uniform distribution in vivo, is still unknown. We prepared biodegradable poly(lactic-co-glycolic acid) (PLGA) nanoparticles with a range of PEG surface densities by blending various ratios of a diblock copolymer of PLGA and 5 kDa poly(ethylene glycol) (PLGA-PEG5k) with PLGA. We then evaluated the impact of PEG surface density, measured using an (1)H NMR method, on mucin binding in vitro, nanoparticle transport in freshly obtained human cervicovaginal mucus (CVM) ex vivo, and nanoparticle distribution in the mouse cervicovaginal tract in vivo. We found that at least 5% PEG was required to effectively shield the nanoparticle core from interacting with mucus components in vitro and ex vivo, thus leading to enhanced nanoparticle distribution throughout the mouse vagina in vivo. We then demonstrated that biodegradable MPP could be formulated from blends of PLGA and PLGA-PEG polymers of various molecular weights, and that these MPP provide tunable drug loading and drug release rates and durations. Overall, we describe a methodology for rationally designing biodegradable, drug-loaded MPP for more uniform delivery to the vagina.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsnano.5b03876

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 52 references

Cited by

Metadata

Authors
Xu, Q., Ensign, L. M., Boylan, N. J., Schön, A., Gong, X., Yang, J.-C., Lamb, N. W., Cai, S., Yu, T., Freire, E., & Hanes, J.
Affiliations
Johns Hopkins University (US)
Corresponding author
Hanes, Justin
Venue
ACS Nano
Published
2015-08-31
Volume
9
Issue
9
Pages
9217-9227
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2257472368
Cited by
568
References
52
Citations by year
2026: 40 · 2025: 68 · 2024: 40 · 2023: 54 · 2022: 48 · 2021: 60 · 2020: 69 · 2019: 58 · 2018: 55 · 2017: 47 · 2016: 26 · 2015: 2
FWCI
24.06
Type
journal article
Language
en
Open access
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institute of Allergy and Infectious Diseases (P30AI094189, R33AI07974)
  • China Scholarship Council
  • Division of Molecular and Cellular Biosciences (MCB-1157506)
  • National Institutes of Health
  • National Institute of General Medical Sciences (GM056550)
  • W. W. Smith Charitable Trust (A1302)
  • National Institute of Child Health and Human Development (R01HD062844)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
  • Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
  • Physical Sciences › Materials Science › Polymers and Plastics › Dendrimers and Hyperbranched Polymers
Keywords
PEGylation, PLGA nanoparticles, mucin binding, cervicovaginal mucus, vaginal drug delivery, nanoparticle distribution, biodegradable nanoparticles, sustained drug release
MeSH terms
Animals, Humans, Mucus, Polyethylene Glycols, Drug Delivery Systems, Paclitaxel, Mice, Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.