The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ratiometric Biosensor for Aggregation-Induced Emission-Guided Precise Photodynamic Therapy
Abstract
Photodynamic therapy faces the barrier of choosing the appropriate irradiation region and time. In this paper, a matrix metalloproteinase-2 (MMP-2) responsive ratiometric biosensor was designed and synthesized for aggregation-induced emission (AIE)-guided precise photodynamic therapy. It was found that the biosensor presented the MMP-2 responsive AIE behavior. Most importantly, it could accurately differentiate the tumor cells from the healthy cells by the fluorescence ratio between freed tetraphenylethylene and protoporphyrin IX (PpIX, internal reference). In vivo study demonstrated that the biosensor could preferentially accumulate in the tumor tissue with a relative long blood retention time. Note that the intrinsic fluorescence of PpIX and MMP-2-triggered AIE fluorescence provided a real-time feedback which guided precise photodynamic therapy in vivo efficiently. This strategy demonstrated here opens a window in the precise medicine, especially for phototherapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accumulation of sub-100 nm polymeric micelles in poorly permeable tumours depends on size
Cabral, H., Matsumoto, Y., Mizuno, K., Chen, Q., Murakami, M., Kimura, M., Terada, Y., Kano, M. R., Miyazono, K., Uesaka, M., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.166 · Cited by 2,429
Delivery of chemotherapeutic drugs in tumour cell-derived microparticles
Tang, K., Zhang, Y., Zhang, H., Xu, P., Liu, J., Ma, J., Lv, M., Li, D., Katirai, F., Shen, G.-X., et al. (2012) · Nature Communications · doi:10.1038/ncomms2282 · Cited by 453
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Chen, C., Ni, X., Jia, S., Liang, Y., Wu, X., Kong, D., & Ding, D. (2019) · Advanced Materials · doi:10.1002/adma.201904914 · Cited by 503
Wang, D., Lee, M. M. S., Shan, G., Kwok, R. T. K., Lam, J. W. Y., Su, H., Cai, Y., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201802105 · Cited by 365
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Metadata
- Authors
- Han, K., Wang, S.-B., Lei, Q., Zhu, J.-Y., & Zhang, X.-Z.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-09-11
- Volume
- 9
- Issue
- 10
- Pages
- 10268-10277
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1457654552
- Cited by
- 221
- References
- 2
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.