Highly Sensitive Porous PDMS-Based Capacitive Pressure Sensors Fabricated on Fabric Platform for Wearable Applications
Open accessAbstract
High Resolution Image Download MS PowerPoint Slide A novel porous polydimethylsiloxane (PDMS)-based capacitive pressure sensor was fabricated by optimizing the dielectric layer porosity for wide-range pressure sensing applications in the sports field. The pressure sensor consists of a porous PDMS dielectric layer and two fabric-based conductive electrodes. The porous PDMS dielectric layer was fabricated by introducing nitric acid (HNO 3 ) into a mixture of PDMS and sodium hydrogen bicarbonate (NaHCO 3 ) to facilitate the liberation of carbon dioxide (CO 2 ) gas, which induces the creation of porous microstructures within the PDMS dielectric layer. Nine different pressure sensors (PS1, PS2,..., PS9) were fabricated in which the porosity (pore size, thickness) and dielectric constant of the PDMS dielectric layers were varied by changing the curing temperature, the mixing proportions of the HNO 3 /PDMS concentration, and the PDMS mixing ratio. The response of the fabricated pressure sensors was investigated for the applied pressures ranging from 0 to 1000 kPa. A relative capacitance change of ∼100, ∼323, and ∼485% was obtained by increasing the curing temperature from 110 to 140 to 170 °C, respectively. Similarly, a relative capacitance change of ∼170, ∼282, and ∼323% was obtained by increasing the HNO 3 /PDMS concentration from 10 to 15 to 20%, respectively. In addition, a relative capacitance change of ∼94, ∼323, and ∼460% was obtained by increasing the PDMS elastomer base/curing agent ratio from 5:1 to 10:1 to 15:1, respectively. PS9 exhibited the highest sensitivity over a wide pressure sensing range (low-pressure ranges (<50 Pa), 0.3 kPa –1; high-pressure ranges (0.2–1 MPa), 3.2 MPa –1 ). From the results, it was observed that the pressure sensors with dielectric layers prepared at relatively higher curing temperatures, higher HNO 3 concentrations, and higher PDMS ratios resulted in increased porosity and provided the highest sensitivity. As an application demonstrator, a wearable fit cap was developed using an array of 16 pressure sensors for measuring and mapping the applied pressures on a player’s head while wearing a helmet. The pressure mapping aids in observing and understanding the proper fit of the helmet in sports applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Epidemiology and Impact of Traumatic Brain Injury: A Brief Overview
Langlois, J. A., Rutland-Brown, W., & Wald, M. M. (2006) · Journal of Head Trauma Rehabilitation · doi:10.1097/00001199-200609000-00001 · Cited by 3,643
Tactile Sensing—From Humans to Humanoids
Dahiya, R. S., Metta, G., Valle, M., & Sandini, G. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2033627 · Cited by 1,851
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I. D., McCluskey, D. K., Tan, C. K. L., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,495
Unreported Concussion in High School Football Players: Implications for Prevention
McCrea, M., Hammeke, T., Olsen, G., Leo, P., & Guskiewicz, K. (2004) · Clinical Journal of Sport Medicine · doi:10.1097/00042752-200401000-00003 · Cited by 1,220
Park, J., Kim, M., Lee, Y., Lee, H. S., & Ko, H. (2015) · Science Advances · doi:10.1126/sciadv.1500661 · Cited by 939
A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 647
Yang, J. C., Kim, J.-O., Oh, J., Kwon, S. Y., Sim, J. Y., Kim, D. W., Choi, H. B., & Park, S. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b03261 · Cited by 595
Flexible and Stretchable Electronics Paving the Way for Soft Robotics
Lu, N., & Kim, D.-H. (2014) · Soft Robotics · doi:10.1089/soro.2013.0005 · Cited by 535
Mimosa‐Inspired Design of a Flexible Pressure Sensor with Touch Sensitivity
Su, B., Gong, S., Ma, Z., Yap, L. W., & Cheng, W. (2015) · Small · doi:10.1002/smll.201403036 · Cited by 383
Energy autonomous electronic skin
García Núñez, C., Manjakkal, L., & Dahiya, R. (2019) · npj Flexible Electronics · doi:10.1038/s41528-018-0045-x · Cited by 332
Atalay, O., Atalay, A., Gafford, J., & Walsh, C. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700237 · Cited by 329
Zhan, Z., Lin, R., Tran, V.-T., An, J., Wei, Y., Du, H., Tran, T., & Lu, W. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b10820 · Cited by 278
Zhao, T., Li, T., Chen, L., Yuan, L., Li, X., & Zhang, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09265 · Cited by 242
Kim, S., Amjadi, M., Lee, T.-I., Jeong, Y., Kwon, D., Kim, M. S., Kim, K., Kim, T.-S., Oh, Y. S., & Park, I. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07636 · Cited by 237
Polymeric foams for flexible and highly sensitive low-pressure capacitive sensors
Pruvost, M., Smit, W. J., Monteux, C., Poulin, P., & Colin, A. (2019) · npj Flexible Electronics · doi:10.1038/s41528-019-0052-6 · Cited by 204
Nanotechnology-Enabled Sensors
Kalantar-zadeh, K., & Fry, B. (2008) · Springer eBooks · doi:10.1007/978-0-387-68023-1 · Cited by 200
On the accuracy of the Head Impact Telemetry (HIT) System used in football helmets
Jadischke, R., Viano, D. C., Dau, N., King, A. I., & McCarthy, J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.05.030 · Cited by 186
Thin and Flexible Carbon Nanotube-Based Pressure Sensors with Ultrawide Sensing Range
Doshi, S. M., & Thostenson, E. T. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00378 · Cited by 151
Oh, J., Kim, J., Kim, Y., Choi, H. B., Yang, J. C., Lee, S., Pyatykh, M., Kim, J., Sim, J. Y., & Park, S. (2019) · Small · doi:10.1002/smll.201901744 · Cited by 144
A Flexible Capacitive Pressure Sensor for Wearable Respiration Monitoring System
Park, S. W., Das, P. S., Chhetry, A., & Park, J. Y. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2749233 · Cited by 139
Yu, G., Hu, J., Tan, J., Gao, Y., Lu, Y., & Xuan, F. (2018) · Nanotechnology · doi:10.1088/1361-6528/aaa855 · Cited by 125
Palaniappan, V., Masihi, S., Panahi, M. S., Maddipatla, D., Bose, A. K., Zhang, X., Narakathu, B. B., Bazuin, B. J., & Atashbar, M. Z. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2989146 · Cited by 121
Self-citationWei, P., Guo, X., Qiu, X., & Yu, D. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab3695 · Cited by 116
Emamian, S., Narakathu, B. B., Chlaihawi, A. A. J., Bazuin, B. J., & Atashbar, M. Z. (2017) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2017.07.045 · Cited by 115
Self-citationDirect Laser Writing of Porous-Carbon/Silver Nanocomposite for Flexible Electronics
Rahimi, R., Ochoa, M., & Ziaie, B. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b02952 · Cited by 102
Porous Polydimethylsiloxane–Silver Nanowire Devices for Wearable Pressure Sensors
Li, D., Shi, S., Chung, H., & Elias, A. L. (2019) · ACS Applied Nano Materials · doi:10.1021/acsanm.9b00807 · Cited by 97
Influence of Permittivity on the Sensitivity of Porous Elastomer-Based Capacitive Pressure Sensors
Liu, S., Lü, J., & Shieh, H. D. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2789242 · Cited by 95
Piezoresistive E‐Skin Sensors Produced with Laser Engraved Molds
dos Santos, A., Pinela, N., Alves, P. U., Santos, R., Fortunato, E. M. C., Martins, R., Águas, H., & Igreja, R. (2018) · Advanced Electronic Materials · doi:10.1002/aelm.201800182 · Cited by 87
Flexible Capacitive Pressure Sensor Based on PDMS Substrate and Ga–In Liquid Metal
Ali, S., Maddipatla, D., Narakathu, B. B., Chlaihawi, A. A. J., Emamian, S., Janabi, F., Bazuin, B. J., & Atashbar, M. Z. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877929 · Cited by 78
Self-citationThermal Decomposition of Sodium Hydrogen Carbonate and Textural Features of Its Calcines
Hartman, M., Svoboda, K., Pohořelý, M., & Šyc, M. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie400896c · Cited by 76
Field-based measures of head impacts in high school football athletes
Broglio, S. P., Eckner, J. T., & Kutcher, J. S. (2012) · Current Opinion in Pediatrics · doi:10.1097/mop.0b013e3283595616 · Cited by 63
Impact test comparisons of 20th and 21st century American football helmets: Laboratory investigation
Bartsch, A., Benzel, E., Mièle, V., & Prakash, V. (2011) · Journal of neurosurgery · doi:10.3171/2011.9.jns111059 · Cited by 63
A Novel Printed Fabric Based Porous Capacitive Pressure Sensor For Flexible Electronic Applications
Masihi, S., Atashbar, M. Z., Panahi, M. S., Maddipatla, D., Bose, A. K., Zhang, X., Hanson, A. J., Palaniappan, V., Narakathu, B. B., & Bazuin, B. J. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956672 · Cited by 63
Self-citationPorous Graphene Oxide–Metal Ion Composite for Selective Sensing of Organophosphate Gases
Shauloff, N., Teradal, N. L., & Jelinek, R. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02367 · Cited by 40
Peng, S., Chen, S., Huang, Y., Pei, S., & Guo, X. (2018) · IEEE Sensors Letters · doi:10.1109/lsens.2018.2887098 · Cited by 25
145 Sport-Related Concussion and Age: Number of Days to Neurocognitive Baseline
Zuckerman, S. L., Odom, M. J., Lee, Y. M., Forbes, J. A., Sills, A. K., & Solomon, G. S. (2012) · Neurosurgery · doi:10.1227/01.neu.0000417735.94052.d6 · Cited by 20
Panahi, M. S., Masihi, S., Maddipatla, D., Bose, A. K., Hajian, S., Hanson, A. J., Palaniappan, V., Narakathu, B. B., Bazuin, B. J., & Atashbar, M. Z. (2020) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps49123.2020.9239439 · Cited by 10
Self-citation
Cited by
Flexible capacitive pressure sensors for wearable electronics
Wang, H., Li, Z., Liu, Z., Fu, J., Shan, T., Yang, X., Lei, Q., Yang, Y., & Li, D. (2022) · Journal of Materials Chemistry C · doi:10.1039/d1tc05304c · Cited by 263
Abdellatif, S. O., Moustafa, A., Khalid, A., & Ghannam, R. (2023) · Micromachines · doi:10.3390/mi14091676 · Cited by 17
Metadata
- Authors
- Masihi, S., Panahi, M., Maddipatla, D., Hanson, A. J., Bose, A. K., Hajian, S., Palaniappan, V., Narakathu, B. B., Bazuin, B. J., & Atashbar, M. Z.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-03-17
- Volume
- 6
- Issue
- 3
- Pages
- 938-949
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3137334297
- Cited by
- 254
- References
- 37
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.