CoChat

Chemical Sensing at the Robot Fingertips: Toward Automated Taste Discrimination in Food Samples

Ciui, Bianca, Martin, Aida, Mishra, Rupesh K., Nakagawa, Tatsuo, Dawkins, Thomas J., Lyu, Mengjia, Cristea, Cecilia, Sandulescu, Robert, Wang, Joseph · 2018 · ACS Sensors

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

The development of robotic sensors that mimic the human sensing capabilities is critical for the interaction and cognitive abilities of modern robots. Though robotic skin with embedded pressure or temperature sensors has received recent attention, robotic chemical sensors have long been unnoticed due to the challenges associated with realizing chemical sensing modalities on robotic platforms. For realizing such chemically sensitive robotic skin, we exploit here the recent advances in wearable chemical sensor technology and flexible electronics, and describe chemical sensing robotic fingers for rapid screening of food flavors and additives. The stretchable taste-sensing finger electrochemical devices are printed on the robotic glove, which simulates the soft skin, and are integrated with a wireless electronic board for real-time data transmission. The printed middle, index, and ring robotic fingers allow accurate discrimination between sweetness, sourness, and spiciness, via direct electrochemical detection of glucose, ascorbic acid, and capsaicin. The sweet-sensing ability has been coupled with a caffeine-sensing robotic finger for rapid screening of the presence of sugar and caffeine in common beverages. The "sense of taste" chemically sensitive robotic technology thus enables accurate discrimination between different flavors, as was illustrated in numerous tests involving a wide range of liquid and solid food samples. Such realization of advanced wearable taste-sensing systems at the robot fingertips should pave the way to automated chemical sensing machinery, facilitating robotic decision for practical food assistance applications, with broad implications to a wide range of robotic sensing applications.

Overview

Integrity signals

Registry

Crossref · 10.1021/acssensors.8b00778

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 46 references

Cited by

Metadata

Authors
Ciui, B., Martin, A., Mishra, R. K., Nakagawa, T., Dawkins, T. J., Lyu, M., Cristea, C., Sandulescu, R., & Wang, J.
Affiliations
  • University of California San Diego (US)
  • Department of Nanoengineering, University of California, San Diego, La Jolla, California 92093, United States
  • Analytical Chemistry Department, UMF Cluj, Napoca 400349, Romania
Corresponding author
Wang, Joseph
Venue
ACS Sensors
Published
2018-09-18
Volume
3
Issue
11
Pages
2375-2384
ISSN
2379-3694 (ISSN-L)
OpenAlex
W2891677153
Cited by
98
References
46
Citations by year
2026: 11 · 2025: 10 · 2024: 15 · 2023: 12 · 2022: 12 · 2021: 15 · 2020: 14 · 2019: 8 · 2018: 1
FWCI
3.80
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Sensors (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Fulbright Association
  • Defense Threat Reduction Agency (HDTRA 1-16-1-0013)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
Keywords
taste discrimination, robotic fingers, glucose detection, ascorbic acid detection, flexible electronics, robotic glove, robot skin
MeSH terms
Wearable Electronic Devices, Beverages, Carbon, Electrodes, Enzymes, Immobilized, Ferrocyanides, Glucose Oxidase, Hydrogen Peroxide, Ink, Plant Extracts, Robotics, Silver, Silver Compounds, Diagnostic Equipment, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.