Rational Design of Surface/Interface Chemistry for Quantitative in Vivo Monitoring of Brain Chemistry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
To understand the molecular basis of brain functions, researchers would like to be able to quantitatively monitor the levels of neurochemicals in the extracellular fluid in vivo. However, the chemical and physiological complexity of the central nervous system (CNS) presents challenges for the development of these analytical methods. This Account describes the rational design and careful construction of electrodes and nanoparticles with specific surface/interface chemistry for quantitative in vivo monitoring of brain chemistry. We used the redox nature of neurochemicals at the electrode/electrolyte interface to establish a basis for monitoring specific neurochemicals. Carbon nanotubes provide an electrode/electrolyte interface for the selective oxidation of ascorbate, and we have developed both in vivo voltammetry and an online electrochemical detecting system for continuously monitoring this molecule in the CNS. Although Ca(2+) and Mg(2+) are involved in a number of neurochemical signaling processes, they are still difficult to detect in the CNS. These divalent cations can enhance electrocatalytic oxidation of NADH at an electrode modified with toluidine blue O. We used this property to develop online electrochemical detection systems for simultaneous measurements of Ca(2+) and Mg(2+) and for continuous selective monitoring of Mg(2+) in the CNS. We have also harnessed biological schemes for neurosensing in the brain to design other monitoring systems. By taking advantage of the distinct reaction properties of dopamine (DA), we have developed a nonoxidative mechanism for DA sensing and a system that can potentially be used for continuously sensing of DA release. Using "artificial peroxidase" (Prussian blue) to replace a natural peroxidase (horseradish peroxidase, HRP), our online system can simultaneously detect basal levels of glucose and lactate. By substituting oxidases with dehydrogenases, we have used enzyme-based biosensing schemes to develop a physiologically relevant system for detecting glucose and lactate in rat brain. Because of their unique optical properties and modifiable surfaces, gold nanoparticles (Au-NPs) have provided a platform of colorimetric assay for in vivo cerebral glucose quantification. We designed and modified the surfaces of Au-NPs and then used a sequence of reactions to produce hydroxyl radicals from glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Subsecond dopamine release promotes cocaine seeking
Phillips, P. E. M., Stuber, G. D., Heien, M. L. A. V., Wightman, R. M., & Carelli, R. M. (2003) · Nature · doi:10.1038/nature01476 · Cited by 1,113
Mattson, M. P. (2007) · Aging Cell · doi:10.1111/j.1474-9726.2007.00275.x · Cited by 751
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Cited by
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Hu, Y., Cheng, H., Zhao, X., Wu, J., Muhammad, F., Lin, S., He, J., Zhou, L., Zhang, C., Deng, Y., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00905 · Cited by 625
Huang, Y., Guo, X., Wu, Y., Chen, X., Feng, L., Xie, N., & Shen, G. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01745-z · Cited by 490
Ma, W., Jiang, Q., Yu, P., Yang, L., & Mao, L. (2013) · Analytical Chemistry · doi:10.1021/ac401576u · Cited by 306
Self-citationSingle-atom Ni-N4 provides a robust cellular NO sensor
Zhou, M., Jiang, Y., Wang, G., Wu, W., Chen, W., Yu, P., Lin, Y., Mao, J., & Mao, L. (2020) · Nature Communications · doi:10.1038/s41467-020-17018-6 · Cited by 266
Self-citation
Metadata
- Authors
- Zhang, M., Yu, P., & Mao, L.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-11
- Volume
- 45
- Issue
- 4
- Pages
- 533-543
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2333068186
- Cited by
- 176
- References
- 6
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.