The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Two-Photon Probes for Intracellular Free Metal Ions, Acidic Vesicles, And Lipid Rafts in Live Tissues
Abstract
Optical imaging with fluorescence microscopy is a vital tool in the study of living systems. The most common method for cell imaging, one-photon microscopy (OPM), uses a single photon of higher energy to excite the fluorophore. However, two-photon microscopy (TPM), which uses two photons of lower energy as the excitation source, is growing in popularity among biologists because of several distinct advantages. Using TPM, researchers can image intact tissue for a long period of time with minimum interference from tissue preparation artifacts, self-absorption, autofluorescence, photobleaching, and photodamage. However, to make TPM a more versatile tool in biology, researchers need a wider variety of two-photon probes for specific applications. In this Account, we describe a series of two-photon probes that we developed that can visualize the distribution of intracellular metal ions, acidic vesicles, and lipid rafts in living cells and tissues. The development of these probes requires a significant two-photon cross section for the bright image and receptors (sensing moieties) that triggers the emission of the two-photon excited fluorescence upon binding with the ions or membrane in the living system. These probes also must be sensitive to the polarity of the environment to allow selective detection of cytosolic and membrane-bound probes. In addition, they need to be cell-permeable, water-soluble for the staining of cells and tissues, and highly photostable for long-term imaging. The resulting probes-AMg1 (Mg(2+)), ACa1-ACa3 (Ca(2+)), AZn1 and AZn2 (Zn(2+)), AH1, AH2, and AL1 (acidic vesicles), and CL2 (membrane)-use 2-acetyl-6-aminonaphthalene as the fluorophore and receptors for the target ions or membrane. All of these two-photon turn-on probes can detect the intracellular free metal ions, acidic vesicles, and lipid rafts at 100-300 microm depth in live tissues. Moreover, with ACa1-AM, we could simultaneously visualize the spontaneous Ca(2+) waves in the somas of neurons and astrocytes at approximately 120 microm depth in fresh hypothalamic slices for more than 1000 s without appreciable decay. Furthermore, AL1 could visualize the transport of the acidic vesicles between cell body and axon terminal along the axon in fresh rat hippocampal slices at approximately 120 microm depth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium signalling: dynamics, homeostasis and remodelling
Berridge, M. J., Bootman, M. D., & Roderick, H. L. (2003) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1155 · Cited by 5,585
Lipid rafts and signal transduction
Simons, K., & Toomre, D. (2000) · Nature Reviews Molecular Cell Biology · doi:10.1038/35036052 · Cited by 5,371
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
The biochemical basis of zinc physiology
Vallee, B. L., & Falchuk, K. H. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.79 · Cited by 2,990
The neurobiology of zinc in health and disease
Frederickson, C. J., Koh, J.-Y., & Bush, A. I. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1671 · Cited by 1,850
Munro, S. (2003) · Cell · doi:10.1016/s0092-8674(03)00882-1 · Cited by 1,514
Microdomains of Intracellular Ca2+: Molecular Determinants and Functional Consequences
Rizzuto, R., & Pozzan, T. (2006) · Physiological Reviews · doi:10.1152/physrev.00004.2005 · Cited by 1,206
Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
A Role for Lipid Shells in Targeting Proteins to Caveolae, Rafts, and Other Lipid Domains
Anderson, R. G. W., & Jacobson, K. (2002) · Science · doi:10.1126/science.1068886 · Cited by 1,125
Cited by
Lanthanide Luminescence for Biomedical Analyses and Imaging
Bünzli, J.-C. G. (2010) · Chemical Reviews · doi:10.1021/cr900362e · Cited by 2,690
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Upconversion nanophosphors for small-animal imaging
Zhou, J., Liu, Z., & Li, F. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15187h · Cited by 1,581
Triplet photosensitizers: from molecular design to applications
Zhao, J., Wu, W., Sun, J., & Guo, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35531d · Cited by 1,579
Nanomaterials for Theranostics: Recent Advances and Future Challenges
Lim, E.-K., Kim, T., Paik, S., Haam, S., Huh, Y.-M., & Lee, K. (2015) · Chemical Reviews · doi:10.1021/cr300213b · Cited by 1,233
Small-Molecule Two-Photon Probes for Bioimaging Applications
Kim, H. M., & Cho, B. R. (2015) · Chemical Reviews · doi:10.1021/cr5004425 · Cited by 1,047
Self-citationDiscerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Fluorescent probes and bioimaging: alkali metals, alkaline earth metals and pH
Yin, J., Hu, Y., & Yoon, J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00275j · Cited by 645
Analytical and bioanalytical applications of carbon dots
Esteves da Silva, J. C. G., & Gonçalves, H. M. R. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.009 · Cited by 629
Fluorescence Polarization/Anisotropy in Diagnostics and Imaging
Jameson, D. M., & Ross, J. A. (2010) · Chemical Reviews · doi:10.1021/cr900267p · Cited by 627
Yuan, L., Wang, L., Agrawalla, B. K., Park, S.-J., Zhu, H., Sivaraman, B., Peng, J., Xu, Q.-H., & Chang, Y.-T. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b00042 · Cited by 558
Fluorescent bioimaging of pH: from design to applications
Hou, J.-T., Ren, W. X., Li, K., Seo, J., Sharma, A., Yu, X.-Q., & Kim, J. S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00719h · Cited by 557
Functional Supramolecular Polymers for Biomedical Applications
Dong, R., Zhou, Y., Huang, X., Zhu, X., Lu, Y., & Shen, J. (2015) · Advanced Materials · doi:10.1002/adma.201402975 · Cited by 535
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Self-citationGu, Z., Yan, L., Tian, G., Li, S., Chai, Z., & Zhao, Y. (2013) · Advanced Materials · doi:10.1002/adma.201301197 · Cited by 491
Wu, W., Guo, H., Wu, W., Ji, S., & Zhao, J. (2011) · The Journal of Organic Chemistry · doi:10.1021/jo200990y · Cited by 415
Bae, S. K., Heo, C. H., Choi, D. J., Sen, D., Joe, E.-H., Cho, B. R., & Kim, H. M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja404004v · Cited by 411
Self-citationRatiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
Lim, C. S., Masanta, G., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205081s · Cited by 365
Self-citationKim, H. J., Heo, C. H., & Kim, H. M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja409971k · Cited by 333
Self-citationSun, W., Fan, J., Hu, C., Cao, J., Zhang, H., Xiong, X., Wang, J., Cui, S., Sun, S., & Peng, X. (2013) · Chemical Communications · doi:10.1039/c3cc41244j · Cited by 303
Small-molecule fluorophores and fluorescent probes for bioimaging
Terai, T., & Nagano, T. (2013) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-013-1234-z · Cited by 301
Gu, B., & Zhang, Q. (2018) · Advanced Science · doi:10.1002/advs.201700609 · Cited by 292
π-Expanded coumarins: synthesis, optical properties and applications
Tasior, M., Kim, D., Singha, S., Krzeszewski, M., Ahn, K. H., & Gryko, D. T. (2015) · Journal of Materials Chemistry C · doi:10.1039/c4tc02665a · Cited by 275
Photoluminescence imaging of Zn2+in living systems
Chen, Y., Bai, Y., Han, Z., He, W., & Guo, Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00005j · Cited by 267
Two‐Photon Fluorescent Probes for Bioimaging
Yao, S., & Belfield, K. D. (2012) · European Journal of Organic Chemistry · doi:10.1002/ejoc.201200281 · Cited by 261
Two-photon luminescent metal complexes for bioimaging and cancer phototherapy
Chen, Y., Guan, R., Zhang, C., Huang, J., Ji, L., & Chao, H. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.09.010 · Cited by 259
Near infrared fluorescent probes for detecting and imaging active small molecules
Ding, C., & Ren, T. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215080 · Cited by 247
Grover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Metadata
- Authors
- Kim, H. M., & Cho, B. R.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-03-31
- Volume
- 42
- Issue
- 7
- Pages
- 863-872
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2094123053
- Cited by
- 542
- References
- 32
- FWCI
- 18.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.