CoChat

NanoFerrite Particle Based Radioimmunonanoparticles: Binding Affinity and In Vivo Pharmacokinetics

Open access
Natarajan, A., Gruettner, C., Ivkov, R., DeNardo, G. L., Mirick, G., Yuan, A., Foreman, A., DeNardo, S. J. · 2008 · Bioconjugate Chemistry
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Dextran and PEG-coated iron oxide nanoparticles (NP), when suitably modified to enable conjugation with molecular targeting agents, provide opportunities to target cancer cells. Monoclonal antibodies, scFv, and peptides conjugated to 20 nm NP have been reported to target cancer for imaging and alternating magnetic field (AMF) therapy. The physical characteristics of NPs can affect their in vivo performance. Surface morphology, surface charge density, and particle size are considered important factors that determine pharmacokinetics, toxicity, and biodistribution. New NanoFerrite (NF) particles having improved specific AMF absorption rates and diameters of 30 and 100 nm were studied to evaluate the variation in their in vitro and in vivo characteristics in comparison to the previously studied 20 nm superparamagnetic iron oxide (SPIO) NP. SPIO NP 20 nm and NF NP 30 and 100 nm were conjugated to (111)In-DOTA-ChL6, a radioimmunoconjugate. Radioimmunoconjugates were conjugated to NPs using 25 microg of RIC/mg of NP by carbodiimide chemistry. The radioimmunonanoparticles (RINP) were purified and characterized by PAGE, cellulose acetate electrophoresis (CAE), live cell binding assays, and pharmacokinetics in athymic mice bearing human breast cancer (HBT 3477) xenografts. RINP (2.2 mg) were injected iv and whole body; blood and tissue data were collected at 4, 24, and 48 h. The preparations used for animal study were >90% monomeric by PAGE and CAE. The immunoreactivity of the RINP was 40-60% compared to (111)In-ChL6. Specific activities of the doses were 20-25 microCi/2.2 mg and 6-11 microg of mAb/2.2 mg of NP. Mean tumor uptakes (% ID/g +/- SD) of each SPIO 20 nm, NF 30 nm, and 100 nm RINP at 48 h were 9.00 +/- 0.8 (20 nm), 3.0 +/- 0.3 (30 nm), and 4.5 +/- 0.8 (100 nm), respectively; the ranges of tissue uptakes were liver (16-32 +/- 1-8), kidney (7.0-15 +/- 1), spleen (8-17 +/- 3-8), lymph nodes 5-6 +/- 1-2), and lung (2.0-4 +/- 0.1-2). In conclusion, this study demonstrated that 100 nm NF NP could be conjugated to (111)In-mAb so that the resulting RINP had characteristics suitable for AMF therapy. Although 100 nm RINP targeted tumor less than 20 nm SPIO RINP, their heating capacity is typically 6 times greater, suggesting the 100 nm NF RINP could still deliver better therapy with AMF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bc800015n

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Natarajan, A., Gruettner, C., Ivkov, R., DeNardo, G. L., Mirick, G., Yuan, A., Foreman, A., & DeNardo, S. J.
Venue
Bioconjugate Chemistry
Published
2008-06-01
Volume
19
Issue
6
Pages
1211-1218
ISSN
  • 1043-1802 (ISSN-L)
  • 1520-4812
OpenAlex
W2089096027
Cited by
111
References
1
FWCI
8.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.