The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Detection of Antigen−Antibody Binding Events with the Atomic Force Microscope
Abstract
An atomic force microscope (AFM) has been used to directly monitor specific interactions between antibodies and antigens employed in an immunoassay system. Results were achieved using AFM probes functionalized with ferritin, and monitoring the adhesive forces between the probe and anti-ferritin antibody-coated substrates. Analysis of the force distribution data suggests a quantization of the forces, with a period of 49 +/- 10 pN. This periodic force may be attributed to single unbinding events between individual antigen and antibody molecules. These results demonstrate that the AFM could be employed as an analytical tool to study the interactions between the molecules involved in biosensor systems. The potential of the technique to provide information relating to the manner in which the antibody molecule binds to its specific antigen is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Specific antigen/antibody interactions measured by force microscopy
Dammer, U., Hegner, M., Anselmetti, D., Wagner, P., Dreier, M., Huber, W., & Güntherodt, H. J. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79814-4 · Cited by 442
Mapping interaction forces with the atomic force microscope
Radmacher, M., Cleveland, J. P., Fritz, M., Hansma, H. G., & Hansma, P. K. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)81011-2 · Cited by 332
Structural features of the reactions between antibodies and protein antigens
Braden, B. C., & Poljak, R. J. (1995) · The FASEB Journal · doi:10.1096/fasebj.9.1.7821765 · Cited by 209
Cited by
Force-distance curves by atomic force microscopy
Cappella, B., & Dietler, G. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00003-5 · Cited by 1,694
Detection and localization of single molecular recognition events using atomic force microscopy
Hinterdorfer, P., & Dufrêne, Y. F. (2006) · Nature Methods · doi:10.1038/nmeth871 · Cited by 1,055
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D. (2003) · Analytical Chemistry · doi:10.1021/ac034356f · Cited by 779
The effect of sedimentation and diffusion on cellular uptake of gold nanoparticles
Cho, E. C., Zhang, Q., & Xia, Y. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.58 · Cited by 719
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Single molecule force spectroscopy in biology using the atomic force microscope
Zlatanova, J., Lindsay, S. M., & Leuba, S. H. (2000) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(00)00014-6 · Cited by 375
Spatially resolved force spectroscopy of biological surfaces using the atomic force microscope
Heinz, W. F., & Hoh, J. H. (1999) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01304-9 · Cited by 373
Patel, N., Davies, M. C., Hartshorne, M., Heaton, R. J., Roberts, C. J., Tendler, S. J. B., & Williams, P. M. (1997) · Langmuir · doi:10.1021/la970933h · Cited by 369
Self-citationSchwesinger, F., Ros, R., Strunz, T., Anselmetti, D., Güntherodt, H.-J., Honegger, A., Jermutus, L., Tiefenauer, L., & Plückthun, A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.18.9972 · Cited by 343
Single Integrin Molecule Adhesion Forces in Intact Cells Measured by Atomic Force Microscopy
Lehenkari, P. P., & Horton, M. A. (1999) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1999.0827 · Cited by 289
San Paulo, A., & García, R. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76712-9 · Cited by 286
Feldman, K., Hähner, G., Spencer, N. D., Harder, P., & Grunze, M. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991049b · Cited by 279
Antibody recognition imaging by force microscopy
Raab, A., Han, W., Badt, D., Smith-Gill, S. J., Lindsay, S. M., Schindler, H., & Hinterdorfer, P. (1999) · Nature Biotechnology · doi:10.1038/12898 · Cited by 260
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Antigen binding forces of individually addressed single-chain Fv antibody molecules
Ros, R., Schwesinger, F., Anselmetti, D., Kubon, M., Schäfer, R., Plückthun, A., & Tiefenauer, L. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.13.7402 · Cited by 253
Nanoscale mapping of the Met receptor on hippocampal neurons by AFM and confocal microscopy
Kawas, L. H., Benoist, C. C., Harding, J. W., Wayman, G. A., & Abu-Lail, N. I. (2013) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2012.08.008 · Cited by 13
Metadata
- Authors
- Allen, S., Chen, X., Davies, J., Davies, M. C., Dawkes, A. C., Edwards, J. C., Roberts, C. J., Sefton, J., Tendler, S. J. B., & Williams, P. M.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-06-01
- Volume
- 36
- Issue
- 24
- Pages
- 7457-7463
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2032641879
- Cited by
- 341
- References
- 5
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.