Biomedical Application of Commercial Polymers and Novel Polyisobutylene-Based Thermoplastic Elastomers for Soft Tissue Replacement
Abstract
Novel polyisobutylene-based thermoplastic elastomers are introduced as prospective implant materials for soft tissue replacement and reconstruction. In comparison, poly(ethylene terephthalate) (PET), poly(tetrafluoroethylene) (PTFE), polypropylene (PP), polyurethanes (PU), and silicones are outlined from well-established implant history as being relatively inert and biocompatible biomaterials for soft tissue replacement, especially in vascular grafts and breast implants. Some general considerations for the design and development of polymers for soft tissue replacement are reviewed from the viewpoint of material science and engineering, with special attention to synthetic materials used in vascular grafts and breast implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomalia, D. A., Naylor, A. M., & Goddard, W. A. (1990) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199001381 · Cited by 3,211
Flow Effects on Prostacyclin Production by Cultured Human Endothelial Cells
Frangos, J. A., Eskin, S. G., McIntire, L. V., & Ives, C. L. (1985) · Science · doi:10.1126/science.3883488 · Cited by 1,235
New Challenges in Biomaterials
Peppas, N. A., & Langer, R. (1994) · Science · doi:10.1126/science.8134835 · Cited by 1,142
Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries.
Asakura, T., & Karino, T. (1990) · Circulation Research · doi:10.1161/01.res.66.4.1045 · Cited by 856
Encyclopedic handbook of biomaterials and bioengineering
Wise, D. L. (1995) · Cited by 584
THE USE OF TUBES CONSTRUCTED FROM VINYON “N” CLOTH IN BRIDGING ARTERIAL DEFECTS A PRELIMINARY REPORT
Voorhees, A. B., Jaretzki, A., & Blakemore, A. H. (1952) · Annals of Surgery · doi:10.1097/00000658-195203000-00006 · Cited by 569
Polyurethanes in Biomedical Applications
Burke, A., & Hasirci, N. (2004) · Advances in Experimental Medicine and Biology · doi:10.1007/978-0-306-48584-8_7 · Cited by 494
Cell behaviour on polymer surfaces with different functional groups
Lee, J. H., Jung, H. W., Kang, I.-K., & Lee, H. B. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90169-4 · Cited by 433
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Matched Elastic Properties and Successful Arterial Grafting
Walden, R. (1980) · Archives of Surgery · doi:10.1001/archsurg.1980.01380100018004 · Cited by 234
Biostability of Polyurethane Elastomers: A Critical Review
Szycher, M. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300207 · Cited by 199
Hårdhammar, P. A., van Beusekom, H. M. M., Emanuelsson, H. U., Hofma, S. H., Albertsson, P. A., Verdouw, P. D., Boersma, E., Serruys, P. W., & van der Giessen, W. J. (1996) · Circulation · doi:10.1161/01.cir.93.3.423 · Cited by 187
Lin, H., Sun, W., Mosher, D. F., García‐Echeverría, C., Schaufelberger, K., Lelkes, P. I., & Cooper, S. L. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280307 · Cited by 178
Wall shear stress temporal gradient and anastomotic intimal hyperplasia.
Ojha, M. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1227 · Cited by 169
Rupture of silicone-gel breast implants: causes, sequelae, and diagnosis
Brown, S. L., Silverman, B. G., & Berg, W. A. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03164-4 · Cited by 166
Wright, C. (1987) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(87)70041-x · Cited by 163
Living carbocationic polymerization of resonance-stabilized monomers
Puskas, J. E., & Kaszás, G. (2000) · Progress in Polymer Science · doi:10.1016/s0079-6700(00)00010-1 · Cited by 156
Self-citationKosmidis, V. A., Achilias, D. S., & Karayannidis, G. P. (2001) · Macromolecular Materials and Engineering · doi:10.1002/1439-2054(20011001)286:10<565::aid-mame565>3.0.co;2-e · Cited by 145
Inhibition of Calcification of Bioprosthetic Heart Valves by Local Controlled-Release Diphosphonate
Levy, R. J., Wolfrum, J. M., Schöen, F. J., Hawley, M., Lund, S. A., & Langer, R. (1985) · Science · doi:10.1126/science.3919445 · Cited by 145
Small Caliber Vascular Grafts. Part II: Polyurethanes Revisited
Zdrahala, R. J. (1996) · Journal of Biomaterials Applications · doi:10.1177/088532829601100102 · Cited by 104
Polyether Polyurethanes: Biostable or Not?
Stokes, K. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300205 · Cited by 103
Tseng, D. Y., & Edelman, E. R. (1998) · Journal of Biomedical Materials Research · Cited by 93
Blood Vessels and Lymphatics in Organ Systems
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-042520-4.x5001-5 · Cited by 79
Hamlin, G. W., Rajah, S. M., Crow, M. J., & Kester, R. C. (1978) · British journal of surgery · doi:10.1002/bjs.1800650416 · Cited by 79
Effect of hard segment chemistry and strain on the stability of polyurethanes: in vivo biostability
Hergenrother, R. W., Wabers, H. D., & Cooper, S. L. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90148-u · Cited by 77
Structural Biological Materials - Design and Structure-Property Relationships
(2000) · Pergamon materials series · doi:10.1016/s1470-1804(00)x8001-7 · Cited by 74
Bakker, D., van Blitterswijk, C., Hesseling, S. C., Koerten, H. K., Kuijpers, W., & Grote, J. J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240407 · Cited by 73
Blood and tissue compatibility of modified polyester: Thrombosis, inflammation, and healing
Chinn, J. A., Sauter, J., Phillips, R. E., Kao, W. J., Anderson, J. M., Hanson, S. R., & Ashton, T. R. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980101)39:1 · Cited by 63
Herman, S. D., & Herman, S. (1984) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198403000-00012 · Cited by 58
Biocompatibility assessment of medical devices and materials
Braybrook, J. H. (1997) · Wiley eBooks · Cited by 55
Reconstruction of the Breast Using Polyurethane-Coated Prostheses
Eyssen, J. E., von Werssowetz, A. J., Middleton, G. D., & Eyssen, J. E. (1984) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198403000-00013 · Cited by 51
In Vitro Measurement of Silicone Bleed From Breast Implants
Yu, L. T., LaTorre, G. P., Marotta, J. S., et al. (1996) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199604000-00011 · Cited by 48
Vascular Prosthese s for Aortocoronary Bypass Grafting: A Review
Tomizawa, Y. (1995) · Artificial Organs · doi:10.1111/j.1525-1594.1995.tb02242.x · Cited by 48
The effect of chain extenders and stabilizers on the in‐vivo stability of polyurethanes
Hergenrother, R. W., Wabers, H. D., & Cooper, S. L. (1992) · Journal of Applied Biomaterials · doi:10.1002/jab.770030104 · Cited by 34
Nonthrombogenic Polymer Vascular Prosthesis
Nojiri, C., Senshu, K., & Okano, T. (1995) · Artificial Organs · doi:10.1111/j.1525-1594.1995.tb02241.x · Cited by 31
Pinchuk, L., Martin, J. B., Esquivel, M. C., & MacGregor, D. C. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300206 · Cited by 27
Amin, P., Wille, J. J., Shah, K. R., & Kydonieus, A. F. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270513 · Cited by 23
Puskas, J. E., Chen, Y., Antony, P., Kwon, Y., Kovar, M., Harbottle, R. R., Jong, K. L. D., Norton, P., Cadieux, P. A., Burton, J. P., et al. (2003) · Polymers for Advanced Technologies · doi:10.1002/pat.392 · Cited by 19
Self-citationStructure/property relationships in polystyrene–polyisobutylene–polystyrene block copolymers
Crawford, D. M., Napadensky, E., Tan, N. C. B., Reuschle, D. A., Mountz, D. A., Mauritz, K. A., Laverdure, K. S., Gido, S. P., Liu, W., & Hsiao, B. S. (2001) · Thermochimica Acta · doi:10.1016/s0040-6031(00)00692-4 · Cited by 19
Chemical, Physical and Mechanical Analysis of Explanted Breast Implants
Wolf, C. J., Brandon, H. J., Young, V. L., Jerina, K. L., & Srivastava, A. P. (1996) · Current topics in microbiology and immunology · doi:10.1007/978-3-642-85226-8_3 · Cited by 18
Christ, F. R., Buchen, S. Y., Fencil, D. A., Knight, P. M., Solomon, K. D., & Apple, D. J. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260505 · Cited by 15
Wolf, C. J., Young, V. L., Jerina, K. L., & Brandon, H. J. (2000) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856200743544 · Cited by 15
Biostability and blood-contacting properties of sulfonate grafted polyurethane and Biomer
Wabers, H. D., McCoy, T. J., Okkema, A. Z., Hergenrother, R. W., Wolf, M. F., & Cooper, S. L. (1993) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856292x00349 · Cited by 12
Clinical reviews: Mammary implants
Kossovsky, N., & Papasian, N. (1992) · Journal of Applied Biomaterials · doi:10.1002/jab.770030313 · Cited by 12
Physical properties of isobutylene based block copolymers
Tse, M. F., Wang, H. ‐., Shaffer, T. D., et al. (2000) · Polymer Engineering and Science · doi:10.1002/pen.11350 · Cited by 9
Humpty Dumpty on Capsular Contracture and Complications
Brody, G. S. (1984) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198404000-00025 · Cited by 8
Cited by
Recent advances in nanocellulose for biomedical applications
Jorfi, M., & Foster, E. J. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41719 · Cited by 738
A Renaissance in Living Cationic Polymerization
Aoshima, S., & Kanaoka, S. (2009) · Chemical Reviews · doi:10.1021/cr900225g · Cited by 682
Jagur‐Grodzinski, J. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.729 · Cited by 394
Telechelic polymers by living and controlled/living polymerization methods
Tasdelen, M. A., Kahveci, M. U., & Yagci, Y. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.10.002 · Cited by 393
Microgels: From responsive polymer colloids to biomaterials
Saunders, B. R., Laajam, N., Daly, E., Teow, S., Hu, X., & Stepto, R. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2008.08.008 · Cited by 354
Metadata
- Authors
- Puskas, J. E., & Chen, Y.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-06
- Volume
- 5
- Issue
- 4
- Pages
- 1141-1154
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1964350561
- Cited by
- 269
- References
- 47
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.