The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Co-Electrospun Nanofiber Fabrics of Poly(l-lactide-co-ε-caprolactone) with Type I Collagen or Heparin
Abstract
Functionally designed elastomeric nanofiber fabrics made of the equimolar copolyester, poly(L-lactide-co-epsilon-caprolactone) (PLCL), with type I collagen or the tri-n-butylamine salt of heparin (heparin-TBA) were co-electrospun using 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP) as a solvent. The co-electrospun fabrics (mixing ratio: 0, 5, 10, 30, 50, 70, and 100 wt % of collagen to PLCL) consisted of nanoscale fibers with a mean diameter ranging from approximately 120 to 520 nm. An increase in collagen content in the solution resulted in a decrease in the mean diameter of fibers. Transmission electron microscopy (TEM) showed that collagen in a co-electrospun fiber was phase-separated to form a dispersed phase, which was localized in the interior and peripheral region in the continuous matrix phase of fibers. The tensile strength was decreased with increasing collagen content. Human umbilical vein endothelial cells (HUVECs) were highly elongated and well spread on the fibrous surfaces of fabrics made of PLCL with 5 wt % or 10 wt % collagen. Heparin-TBA (mixing ratio: 1, 5, and 10 wt % to PLCL), soluble in HFIP, was co-electrospun with PLCL to form a fabric. TEM observation showed that heparin-TBA formed as a dispersed phase in a PLCL nanofiber. The releasing rate, released amount, and surface content of heparin-TBA were increased with increasing heparin-TBA content in co-electrospun fabrics. The potential biomedical application of co-electrospun PLCL with type I collagen or heparin-TBA was discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keun Kwon, I., Kidoaki, S., & Matsuda, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.007 · Cited by 607
Self-citation(Co)polymers of L‐lactide, 2. Mechanical properties
Grijpma, D. W., & Pennings, A. J. (1994) · Macromolecular Chemistry and Physics · doi:10.1002/macp.1994.021950516 · Cited by 191
Cited by
Sell, S. A., Wolfe, P. S., Garg, K., McCool, J. M., Rodriguez, I. A., & Bowlin, G. L. (2010) · Polymers · doi:10.3390/polym2040522 · Cited by 578
Li, M., Mondrinos, M. J., Chen, X., Gandhi, M. R., Ko, F. K., & Lelkes, P. I. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30833 · Cited by 358
Kharaziha, M., Nikkhah, M., Shin, S.-R., Annabi, N., Masoumi, N., Gaharwar, A. K., Camci-Unal, G., & Khademhosseini, A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.045 · Cited by 313
Powell, H. M., & Boyce, S. T. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0473 · Cited by 267
Nanostructured Biocomposite Scaffolds Based on Collagen Coelectrospun with Nanohydroxyapatite
Thomas, V., Dean, D. R., Jose, M. V., Mathew, B., Chowdhury, S., & Vohra, Y. K. (2007) · Biomacromolecules · doi:10.1021/bm060879w · Cited by 259
Metadata
- Authors
- Kwon, I. K., & Matsuda, T.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-26
- Volume
- 6
- Issue
- 4
- Pages
- 2096-2105
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1997881196
- Cited by
- 208
- References
- 2
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.