In Vitro and in Vivo Release of Albumin Using a Biodegradable MPEG-PCL Diblock Copolymer as an in Situ Gel-Forming Carrier
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An MPEG-PCL diblock copolymer was synthesized as an in situ gel carrier, and its phase transition behavior in aqueous solutions was examined. For comparison, aqueous solutions of Pluronic F-127, a widely used injectable gel-forming solution, were also studied. Both MPEG-PCL copolymer and Pluronic aqueous solutions were sols at room temperature. As the temperature was increased above room temperature, the diblock copolymer and Pluronic solutions underwent a sol-to-gel phase transition, which manifested as an increase in viscosity indicative of the formation of a gel. All of the copolymer solutions became gels at body temperature, although the gel viscosity increased with the increasing concentration of the MPEG-PCL diblock copolymer in the solution. In in vitro experiments, in which the gels were exposed to PBS, the MPEG-PCL gels maintained their structural integrity for more than 28 days, whereas the Pluronic gel disappeared within 2 days. The same results were observed when the polymer solutions were subcutaneously injected into rats. The MPEG-PCL gels maintained their structural integrity longer than 30 days, while the Pluronic gel could not be observed after 2 days. The ability of the gels as drug carriers was studied by measuring the release of fluorescein isothiocyanate-labeled bovine serum albumin (BSA-FITC) from MPEG-PCL diblock copolymer gels in vitro as well as in vivo. In vitro, BSA release was sustained above 20 days, with a greater release at lower diblock copolymer concentration; by contrast, Pluronic gels exhibited almost complete release of BSA-FITC within 1 day. When the BSA-FITC-loaded diblock copolymer and Pluronic solutions were subcutaneously injected into rats, they immediately transformed into a gel. In vivo, sustained release of BSA-FITC over 30 days was observed from the MPEG-PCL gel, whereas BSA-FITC release from the Pluronic gel ceased within 3 days. Collectively, the present findings show that MPEG-PCL diblock copolymer solutions are thermo-responsive and maintain their structural integrity under physiological conditions, indicating that they are suitable for use as injectable drug carriers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Pluronic® block copolymers as novel polymer therapeutics for drug and gene delivery
Kabanov, A. V., Batrakova, E. V., & Alakhov, V. Y. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00009-3 · Cited by 1,474
Self-porating polymersomes of peg–pla and peg–pcl: Hydrolysis-triggered controlled release vesicles
Ahmed, F., & Discher, D. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.12.021 · Cited by 667
Cited by
Hydrogels in drug delivery: Progress and challenges
Hoare, T. R., & Kohane, D. S. (2008) · Polymer · doi:10.1016/j.polymer.2008.01.027 · Cited by 3,776
Injectable hydrogels as unique biomedical materials
Yu, L., & Ding, J. (2008) · Chemical Society Reviews · doi:10.1039/b713009k · Cited by 1,545
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
Biodegradable synthetic polymers: Preparation, functionalization and biomedical application
Tian, H., Tang, Z., Zhuang, X., Chen, X., & Jing, X. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.004 · Cited by 1,293
Hydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
In situ gelling stimuli-sensitive block copolymer hydrogels for drug delivery
He, C., Kim, S. W., & Lee, D. S. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.005 · Cited by 867
Hydrogel scaffolds for tissue engineering: the importance of polymer choice
Spicer, C. D. (2020) · Polymer Chemistry · doi:10.1039/c9py01021a · Cited by 527
Zustiak, S. P., & Leach, J. B. (2010) · Biomacromolecules · doi:10.1021/bm100137q · Cited by 493
Injectable Biodegradable Hydrogels
Nguyen, M. K., & Lee, D. S. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900402 · Cited by 481
Temperature-responsive compounds as in situ gelling biomedical materials
Moon, H. J., Ko, D. Y., Park, M. H., Joo, M. K., & Jeong, B. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35078e · Cited by 421
Hydrogel scaffolds for differentiation of adipose-derived stem cells
Huang, Q., Zou, Y., Arno, M. C., Chen, S., Wang, T., Gao, J., Dove, A. P., & Du, J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00052e · Cited by 400
Singh, N. K., & Lee, D. S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.056 · Cited by 326
In situ forming implants — an attractive formulation principle for parenteral depot formulations
Kempe, S., & Mäder, K. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.016 · Cited by 323
Hydrogels for Hydrophobic Drug Delivery. Classification, Synthesis and Applications
Larrañeta, E., Stewart, S., Ervine, M., Al-Kasasbeh, R., & Donnelly, R. (2018) · Journal of Functional Biomaterials · doi:10.3390/jfb9010013 · Cited by 303
PCL-PEG copolymer based injectable thermosensitive hydrogels
Dethe, M. R., A, P., Ahmed, H., Agrawal, M., Roy, U., & Alexander, A. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.01.035 · Cited by 263
Injectable Block Copolymer Hydrogels: Achievements and Future Challenges for Biomedical Applications
Huynh, C. T., Nguyen, M. K., & Lee, D. S. (2011) · Macromolecules · doi:10.1021/ma201261m · Cited by 240
Bioactive factor delivery strategies from engineered polymer hydrogels for therapeutic medicine
Nguyen, M. K., & Alsberg, E. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.12.001 · Cited by 226
“everal other di- and triblock thermo-sensitive copolyers for therapeutics delivery based on PEG with PCL and oly( -valerolactone) (PVL) have also been prepared via OP using CL and -valerolactone (VL) [52,64–66].”
Park, M. H., Joo, M. K., Choi, B. G., & Jeong, B. (2012) · Accounts of Chemical Research · doi:10.1021/ar200162j · Cited by 226
Biomaterials for vaccine-based cancer immunotherapy
Zhang, R., Billingsley, M. M., & Mitchell, M. J. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.10.008 · Cited by 200
Deng, H., Dong, A., Song, J., & Chen, X. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.01.026 · Cited by 181
Engineered in-situ depot-forming hydrogels for intratumoral drug delivery
Fakhari, A., & Anand Subramony, J. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.11.014 · Cited by 164
Thermosensitive Polymeric Hydrogels As Drug Delivery Systems
Gong, C., Qi, T., Wei, X., Qu, Y., Wu, Q., Luo, F., & Qian, Z. (2012) · Current Medicinal Chemistry · doi:10.2174/09298673130109 · Cited by 161
“In vitro and in vivo release behaviors of FITC labeled BSA from MPEG-PCL hydrogel were studied [219].”
Background
Metadata
- Authors
- Hyun, H., Kim, Y. H., Song, I. B., Lee, J. W., Kim, M. S., Khang, G., Park, K., & Lee, H. B.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-28
- Volume
- 8
- Issue
- 4
- Pages
- 1093-1100
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1970644492
- Cited by
- 128
- References
- 3
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.