The DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Cross-Reactive Chemical Sensor Arrays
Abstract
Conventional approaches to chemical sensors have \ntraditionally made use of a “lock-and-key” design, \nwherein a specific receptor is synthesized in order to \nstrongly and highly selectively bind the analyte of \ninterest.1-6 A related approach involves exploiting a \ngeneral physicochemical effect selectively toward a \nsingle analyte, such as the use of the ionic effect in \nthe construction of a pH electrode. In the first \napproach, selectivity is achieved through recognition \nof the analyte at the receptor site, and in the second, \nselectivity is achieved through the transduction \nprocess in which the method of detection dictates \nwhich species are sensed. Such approaches are appropriate \nwhen a specific target compound is to be \nidentified in the presence of controlled backgrounds \nand interferences. However, this type of approach \nrequires the synthesis of a separate, highly selective \nsensor for each analyte to be detected. In addition, \nthis type of approach is not particularly useful for \nanalyzing, classifying, or assigning human value \njudgments to the composition of complex vapor \nmixtures such as perfumes, beers, foods, mixtures of \nsolvents, etc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
Kirkpatrick, S. (1973) · Reviews of Modern Physics · doi:10.1103/revmodphys.45.574 · Cited by 5,260
Draper, N. R., & Smith, H. (1998) · Wiley Series in Probability and Statistics · doi:10.1002/9781118625590 · Cited by 5,024
A novel multigene family may encode odorant receptors: A molecular basis for odor recognition
Buck, L., & Axel, R. (1991) · Cell · doi:10.1016/0092-8674(91)90418-x · Cited by 4,987
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Principles of Instrumental Analysis
(2001) · Laboratory Guide for Conducting Soil Tests and Plant Analysis · doi:10.1201/9781420025293.ch5 · Cited by 3,638
Cited by
Organometallic Chemistry on Silicon and Germanium Surfaces
Buriak, J. M. (2002) · Chemical Reviews · doi:10.1021/cr000064s · Cited by 1,720
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Conducting polymers in electronic chemical sensors
Janata, J., & Josowicz, M. (2003) · Nature Materials · doi:10.1038/nmat768 · Cited by 1,349
Lan, A., Li, K., Wu, H., Olson, D. H., Emge, T. J., Ki, W., Hong, M., & Li, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804853 · Cited by 1,237
Radiative Decay Engineering: Biophysical and Biomedical Applications
Lakowicz, J. R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5377 · Cited by 1,217
The Optoelectronic Nose: Colorimetric and Fluorometric Sensor Arrays
Li, Z., Askim, J. R., & Suslick, K. S. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00226 · Cited by 1,191
Applications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144
Chemical Sensing and Catalysis by One‐Dimensional Metal‐Oxide Nanostructures
Kolmakov, A., & Moskovits, M. (2004) · ChemInform · doi:10.1002/chin.200441227 · Cited by 914
A water-soluble cationic oligopyrene derivative: Spectroscopic studies and sensing applications
Chen, Y., Bai, H., Chen, Q., Li, C., & Shi, G. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.047 · Cited by 845
A review of gas sensors employed in electronic nose applications
Arshak, K., Moore, E., Lyons, G. M., Harris, J., & Clifford, S. (2004) · Sensor Review · doi:10.1108/02602280410525977 · Cited by 802
Detection of Nitroaromatic Explosives Based on Photoluminescent Polymers Containing Metalloles
Sohn, H., Sailor, M. J., Magde, D., & Trogler, W. C. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021214e · Cited by 673
Ultrasensitive Chemiresistors Based on Electrospun TiO2 Nanofibers
Kim, I.-D., Rothschild, A., Lee, B. H., Kim, D. Y., Jo, S. M., & Tuller, H. L. (2006) · Nano Letters · doi:10.1021/nl061197h · Cited by 593
Combinatorial and High-Throughput Screening of Materials Libraries: Review of State of the Art
Potyrailo, R., Rajan, K., Stoewe, K., Takeuchi, I., Chisholm, B., & Lam, H. (2011) · ACS Combinatorial Science · doi:10.1021/co200007w · Cited by 511
The electronic nose applied to dairy products: a review
Ampuero, S., & Bosset, J. O. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00321-6 · Cited by 485
Detection of Bacteria with Carbohydrate-Functionalized Fluorescent Polymers
Disney, M. D., Zheng, J., Swager, T. M., & Seeberger, P. H. (2004) · Journal of the American Chemical Society · doi:10.1021/ja047936i · Cited by 457
Data analysis for electronic nose systems
Scott, S. M., James, D., & Ali, Z. (2006) · Microchimica Acta · doi:10.1007/s00604-006-0623-9 · Cited by 450
Semiconducting Metal Oxide Based Sensors for Selective Gas Pollutant Detection
Kanan, S. M., El-Kadri, O. M., Abu-Yousef, I. A., & Kanan, M. C. (2009) · Sensors · doi:10.3390/s91008158 · Cited by 447
El-Boubbou, K., Gruden, C., & Huang, X. (2007) · Journal of the American Chemical Society · doi:10.1021/ja076086e · Cited by 421
Sensor arrays for liquid sensing – electronic tongue systems
Ciosek, P., & Wróblewski, W. (2007) · The Analyst · doi:10.1039/b705107g · Cited by 408
Carbon Nanotube/Polythiophene Chemiresistive Sensors for Chemical Warfare Agents
Wang, F., Gu, H., & Swager, T. M. (2008) · Journal of the American Chemical Society · doi:10.1021/ja710795k · Cited by 391
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Multi‐Functional Integration of Organic Field‐Effect Transistors (OFETs): Advances and Perspectives
Di, C., Zhang, F., & Zhu, D. (2013) · Advanced Materials · doi:10.1002/adma.201201502 · Cited by 330
Bajaj, A., Miranda, O. R., Kim, I.-B., Phillips, R. L., Jerry, D. J., Bunz, U. H. F., & Rotello, V. M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900975106 · Cited by 309
Colorimetric sensor array based on gold nanoparticles: Design principles and recent advances
Sun, J., Lu, Y., He, L., Pang, J., Yang, F., & Liu, Y. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115754 · Cited by 299
Bohrer, F. I., Colesniuc, C. N., Park, J., Ruidiaz, M. E., Schuller, I. K., Kummel, A. C., & Trogler, W. C. (2009) · Journal of the American Chemical Society · doi:10.1021/ja803531r · Cited by 292
Sensors, Chemical Sensors, Electrochemical Sensors, and ECS
Stetter, J. R., Penrose, W. R., & Yao, S. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1539051 · Cited by 290
Shellaiah, M., Wu, Y.-H., Singh, A., Ramakrishnam Raju, M. V., & Lin, H.-C. (2013) · J. Mater. Chem. A · doi:10.1039/c2ta00574c · Cited by 287
A Gradient Microarray Electronic Nose Based on Percolating SnO2 Nanowire Sensing Elements
Sysoev, V. V., Goschnick, J., Schneider, T., Strelcov, E., & Kolmakov, A. (2007) · Nano Letters · doi:10.1021/nl071815+ · Cited by 272
Vapochromic crystals: understanding vapochromism from the perspective of crystal engineering
Li, E., Jie, K., Liu, M., Sheng, X., Zhu, W., & Huang, F. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00098d · Cited by 267
Array-Based Sensing of Proteins Using Conjugated Polymers
Miranda, O. R., You, C.-C., Phillips, R., Kim, I.-B., Ghosh, P. S., Bunz, U. H. F., & Rotello, V. M. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0737927 · Cited by 267
Nanoparticle-based optical sensor arrays
Bigdeli, A., Ghasemi, F., Golmohammadi, H., Abbasi-Moayed, S., Nejad, M. A. F., Fahimi-Kashani, N., Jafarinejad, S., Shahrajabian, M., & Hormozi-Nezhad, M. R. (2017) · Nanoscale · doi:10.1039/c7nr03311g · Cited by 265
Artificial sensing intelligence with silicon nanowires for ultraselective detection in the gas phase
Wang, B., Cancilla, J. C., Torrecilla, J. S., & Haick, H. (2014) · Nano Letters · doi:10.1021/nl404335p · Cited by 236
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202200830 · Cited by 183
Metadata
- Authors
- Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-06-24
- Volume
- 100
- Issue
- 7
- Pages
- 2595-2626
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2091089517
- Cited by
- 1,284
- References
- 84
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.