Indoor Particulate Matter of Outdoor Origin: Importance of Size-Dependent Removal Mechanisms
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Adverse human health effects have been observed to correlate with levels of outdoor particulate matter (PM), even though most human exposure to PM of outdoor origin occurs indoors. In this study, we apply a model and empirical data to explore the indoor PM levels of outdoor origin for two major building types: offices and residences. Typical ventilation rates for each building type are obtained from the literature. Published data are combined with theoretical analyses to develop representative particle penetration coefficients, deposition loss rates, and ventilation-system filter efficiencies for a broad particle size range (i.e., 0.001-10 microm). We apply archetypal outdoor number, surface area, and mass PM size distributions for both urban and rural airsheds. We also use data on mass-weighted size distributions for specific chemical constituents of PM: sulfate and elemental carbon. Predictions of the size-resolved indoor proportion of outdoor particles (IPOP) for various conditions and ambient particle distributions are then computed. The IPOP depends strongly on the ambient particle size distribution, building type and operational parameters, and PM metric. We conclude that an accurate determination of exposure to particles of ambient origin requires explicit consideration of how removal processes in buildings vary with particle size.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Riley et al. [10] suggested that the penetration of particles through building cracks would significantly affect indoor air quality, especially for buildings where air exchange through openings or cracks is dominated by pressure differences arising from natural forces.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [10]
Citations
Cites
Atmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Chemistry of the Upper and Lower Atmosphere: Theory, Experiments, and Applications
Finlayson‐Pitts, B. J., & PITTS, J. N. J. (1999) · Cited by 3,055
Uncertainty: A Guide to Dealing with Uncertainty in Quantitative Risk and Policy Analysis
Morgan, M. G., & Henrion, M. (1990) · Cambridge University Press eBooks · doi:10.1017/cbo9780511840609 · Cited by 1,711
Is Daily Mortality Associated Specifically with Fine Particles?
Schwartz, J., Dockery, D. W., & Neas, L. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467528 · Cited by 1,561
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Air pollution and incidence of cardiac arrhythmia
Peters, A., Liu, E., Verrier, R. L., Schwartz, J., Gold, D. R., Mittleman, M., Baliff, J., Oh, J. A., Allen, G., Monahan, K., et al. (2000) · Epidemiology · doi:10.1097/00001648-200001000-00005 · Cited by 651
Activity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Radon and its decay products in indoor air
Benarie, M. (1989) · Science of The Total Environment · doi:10.1016/0048-9697(89)90061-2 · Cited by 402
Jones, N. C., Thornton, C. A., Mark, D., & Harrison, R. M. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00489-6 · Cited by 374
Research works printed but not linked: 15
- Klemm R. J., 2000, J. Air Waste Manage. Assoc., 50, 1222
- Pope C. A., 1999, Am. Heart J., 138, 899
- Klepeis N. E., 2001, J. Exposure Anal. Environ. Epidemiol., 11, 252
- Lioy P. J., 1988, Arch. Environ. Health, 43, 312
- Yocum J. E., 1982, JAPCA, 32, 520
- Ozkaynak H., 1996, J. Exposure Anal. Environ. Epidemiol., 6, 78
- Long C. M., 2001, Environ. Sci. Technol., 35, 2099
- Abt E., 2000, Environ. Sci. Technol., 34, 3587
- Persily A., 1989, IAQ '89 Conference
- ASHRAE., 1993, ASHRAE Handbook: Fundamentals
- Xu M. D., 1994, Aerosol Sci. Technol., 20, 206
- Fogh C. L., 1997, Atmos. Environ., 31, 2203
- Liu D., 2001, Atmos. Environ., 35, 4462
- Whitby K. T., 1978, Atmos. Environ., 12, 159
- Ott W., 2000, J. Air Waste Manage. Assoc., 50, 1406
Cited by
Items 301–400 of 417
Cao, J., Han, Y. Q., Zhu, Y., Duan, X., Wang, L., & Huang, H. (2022) · Building Simulation · doi:10.1007/s12273-022-0962-4 · Cited by 8
Contributing factors to the development of childhood asthma: working toward risk minimization
Guibas, G. V., Megremis, S., West, P., & Papadopoulos, N. G. (2015) · Expert Review of Clinical Immunology · doi:10.1586/1744666x.2015.1035649 · Cited by 11
Particles in the Indoor Environment
Fromme, H. (2012) · InTech eBooks · doi:10.5772/34319 · Cited by 15
Cao, Q., Chen, A., Zhou, J. Z., & Chang, V. W.-C. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.08.004 · Cited by 8
Behavioral characteristics to airborne particles generated from commercial spray products
Kim, T., Park, J., Seo, J., Yoon, H., Lee, B., Lim, H., Lee, D., Kim, P., Yoon, C., Lee, K., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105747 · Cited by 9
Effect Of Ventilation On Chronic Health Risks In Schools And Offices
Lawrence Berkeley National Lab. (LBNL), B., Parthasarathy, S., USDOE Office of Science (SC), Fisk, W. J., & McKone, T. E. (2013) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1169483 · Cited by 8
Self-citationUpdating aB. anthracisRisk Model with Field Data from a Bioterrorism Incident
Hong, T., & Gurian, P. L. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b00010 · Cited by 7
Nano-sized emission from commercially available paints used for indoor surfaces during drying
Jørgensen, R. B., Hveding, I. G., & Solheim, K. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.09.028 · Cited by 7
Rackes, A., Ben-David, T., & Waring, M. S. (2018) · Indoor Air · doi:10.1111/ina.12466 · Cited by 9
Vijay, S., & Wang, J. (2022) · Indoor Air · doi:10.1111/ina.13080 · Cited by 7
A Risk Assessment Scheme of Infection Transmission Indoors Incorporating the Impact of Resuspension
You, S., & Wan, M. P. (2015) · Risk Analysis · doi:10.1111/risa.12350 · Cited by 7
Ji, W., & Zhao, B. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.025 · Cited by 7
User Influence on Indoor Aerosol Model Calibration
Hussein, T., Mølgaard, B., & Hämeri, K. J. (2011) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2010.12.0104 · Cited by 7
Firrantello, J., Aumpansub, P., Bahnfleth, W. P., Hu, B., Freihaut, J. D., Thran, B. H., & Hutchens, S. (2007) · Journal of Architectural Engineering · doi:10.1061/(asce)1076-0431(2007)13:2(84 · Cited by 7
A Numerical Study of the Particle Penetration Coefficient of Multibended Building Crack
Yang, Y. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.02.0058 · Cited by 7
Berman, B. C., Cummings, B. E., Avery, A. M., DeCarlo, P. F., Capps, S. L., & Waring, M. S. (2022) · Indoor Air · doi:10.1111/ina.13075 · Cited by 7
Experimental study on the effect of adjacent near-wall heat sources on the particle deposition
Chen, X., Qin, M., Liu, S., Jiang, S., Liu, Y., Liu, Y., & Tariq, J. (2024) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.172889 · Cited by 6
Wagner, D. N., Odhiambo, S. R., Ayikukwei, R., & Boor, B. E. (2022) · Indoor Air · doi:10.1111/ina.13132 · Cited by 5
Eom, Y. S., & Rim, D. (2024) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2024.106346 · Cited by 6
El-Batrawy, O. (2010) · Cited by 6
Energy Demands and Efficiency Strategies in Data Center Buildings
Lawrence Berkeley National Lab. (LBNL), B., Shehabi, A., & USDOE (2009) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/982905 · Cited by 6
Making the Invisible Visible: The Impact of Revealing Indoor Air Pollution on Behavior and Welfare
Metcalfe, R., & Roth, S. (2025) · National Bureau of Economic Research · doi:10.3386/w33510 · Cited by 14
Chu, Y., Xu, P., Yang, Z., & Li, W. (2017) · Building Services Engineering Research and Technology · doi:10.1177/0143624417728187 · Cited by 5
Pereira, M. L., Vilain, R., Galvão, F. H. F., Tribess, A., & Morawska, L. (2012) · Indoor and Built Environment · doi:10.1177/1420326x12460707 · Cited by 5
Infiltration of Black Carbon Particles from Residential Woodsmoke into Nearby Homes
Thatcher, T. L., Kirchstetter, T. W., Malejan, C. J., & Ward, C. E. (2014) · Open Journal of Air Pollution · doi:10.4236/ojap.2014.34011 · Cited by 5
Lu, F. F., Zhou, B., Xu, Y., Xue, K., Li, Y., Zhang, R., Wei, P., & Huang, R. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.02.017 · Cited by 5
Solid Oxygen-Purifying (SOP) Filters: A Self-Disinfecting Filters to Inactivate Aerosolized Viruses
Versoza, M. E., Heo, J., Ko, S., Kim, M., & Park, D. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17217858 · Cited by 6
Modeling particle fate in ventilation system—Part II: Case study
Zhao, B., & Wu, J. W. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.05.007 · Cited by 5
Chudnovsky, A., Ben‐Dor, E., & Saaroni, H. (2007) · Advances in geosciences · doi:10.5194/adgeo-12-51-2007 · Cited by 5
Inhalation of Vehicle Emissions in Urban EnvironmentsPreprint
Marshall, J. D. (2005) · RePEc: Research Papers in Economics · Cited by 6
Sun, Y., Mo, D., Lin, L., Wang, H., Cao, J., & Bu, Z. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.139626 · Cited by 4
Air quality in and around traffic tunnels
Longley, I. D., & Kelly, F. (2008) · Cited by 5
Kim, D., Min, G., Shin, J., Choe, Y., Choi, K., Sim, S. H., & Yang, W. (2024) · Korean Journal of Environmental Health Sciences · doi:10.5668/jehs.2024.50.1.16 · Cited by 4
Thermally Modified Calcium Oxalate Phytoliths as Markers for Biomass Fire Sources
Crutcher, R., & Crutcher, H. (2020) · The Microscope · doi:10.59082/qimk8305 · Cited by 4
Shinohara, N., Tatsu, K., Naito, W., Murashima, Y., Sakurai, H., Kizu, T., & Kan, K. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113186 · Cited by 4
Wallace, L. A., & Smith, K. R. (2006) · CRC Press eBooks · doi:10.1201/9781420012637.ch8 · Cited by 4
Charron, A., & Harrison, R. M. (2009) · Wiley eBooks · doi:10.1002/9781444307504.ch5 · Cited by 6
Ding, Y., Jiang, X., Zhang, D., Yao, Y., Zhao, W., & He, Y. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110098 · Cited by 3
Elsayed, M., Silvonen, V., Luoto, A., Lintusaari, H., Hakala, J. P., Timonen, H., Harni, S., Rönkkö, T., & Sormunen, P. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112865 · Cited by 4
Mahdavi, A., Dingle, J. H., Chan, A. W. H., & Siegel, J. A. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.116388 · Cited by 5
Eom, Y.-S., Ahn, S., & Shadbegian, R. (2024) · Journal of Environmental Management · doi:10.1016/j.jenvman.2024.123407 · Cited by 3
Reducing in-home exposure to air pollution
Singer, B. C. (2016) · Cited by 3
A Novel Method for Determining Infiltration of Mechanically Ventilated Buildings
Kulmala, I. K., Parviainen, H., Hall, I., & Pasanen, P. O. (2019) · Science and Technology for the Built Environment · doi:10.1080/23744731.2019.1620577 · Cited by 3
Thatcher, T. L., Lunden, M. M., Sextro, R. G., Hering, S. V., & Brown, N. J. (2002) · University of North Texas Digital Library (University of North Texas) · Cited by 3
Marsik, T., & Johnson, R. (2007) · Indoor and Built Environment · doi:10.1177/1420326x07084288 · Cited by 3
Qhekwana, M., Letsholo, T. A. F., Burger, R. P., & Piketh, S. (2017) · International Conference on the Domestic Use of Energy (DUE) · doi:10.23919/due.2017.7931821 · Cited by 4
Xie, Y., Zhao, B., & Li, T. (2018) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.12.002 · Cited by 4
Hejazi, B., Schlenczek, O., Thiede, B., Bagheri, G., & Bodenschatz, E. (2021) · medRxiv · doi:10.1101/2021.05.21.21257577 · Cited by 3
Modeling Indoor Inorganic Aerosol Concentrations During the ATHLETIC Campaign with IMAGES
Berman, B. C., Cummings, B. E., Guo, H., Campuzano‐Jost, P., Jimenez, J. L., Pagonis, D., Day, D. A., Finewax, Z., Handschy, A. V., Nault, B. A., et al. (2024) · ACS ES&T Air · doi:10.1021/acsestair.4c00060 · Cited by 2
Field measurements of fine and ultrafine particle penetration factors in Chicago residences
Farhoodi, S., Zhao, H., Heidarinejad, M., & Stephens, B. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113700 · Cited by 2
Impact of surface roughness on particle penetration through building envelope leakage
Tian, L., Zhang, G., Yu, J., Zhang, Q., & Zhou, J. Z. (2008) · International Journal of Energy Technology and Policy · doi:10.1504/ijetp.2008.020740 · Cited by 2
Development of nanofiber filters with high PM2.5 removal efficiency and low air resistance
Bian, Y., Chen, C., & Zhang, L. (2017) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano.2017.8117392 · Cited by 2
Assessing Mitigation Strategies to Reduce Potential Exposures to Indoor Particle Release Events
Valkinburgh, K. V., Nafchi, A. M., Mousavi, E. S., Blouin, V. Y., Kaye, N. B., & Metcalf, A. R. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220054 · Cited by 2
Silver, D. J. (2005) · Digital Commons - University of South Florida (University of South Florida) · Cited by 3
Waye, S. K. (2008) · Texas ScholarWorks (Texas Digital Library) · Cited by 3
Gall, E. T. (2013) · Texas ScholarWorks (Texas Digital Library) · Cited by 1
Evaluation of outdoor and indoor dust deposition as environmental pollution in Erbil province
Aziz, F. H., & Al-Dabagh, J. J. (2012) · WIT transactions on ecology and the environment · doi:10.2495/air120311 · Cited by 2
PROBE-PM: A new way to simulate particle transport in ventilation systems
Zhao, B., Wang, Y., & Yan, B. (2008) · Building Simulation · doi:10.1007/s12273-008-8317-3 · Cited by 2
Indoor secondary organic aerosol formation : influence of particle controls, mixtures, and surfaces
Waring, M. S. (2009) · Texas ScholarWorks (Texas Digital Library) · Cited by 3
HVAC filters as “passive ” samplers: fate analysis of indoor particles
Noris, F., Kinney, K. A., & Siegel, J. A. (2015) · Cited by 2
Control of fine particulate pollution inside entrance booths
Wang, R., Chen, Q., & Zhao, B. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106576 · Cited by 2
Wang, W., Kimoto, S., Huang, R., Matsui, Y., Yoneda, M., Wang, H., & Wang, B. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.151527 · Cited by 2
On the Risk of Infection by Infectious Aerosols in Large Indoor Spaces
Hejazi, B., Schlenczek, O., Thiede, B., Bagheri, G., & Bodenschatz, E. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220117 · Cited by 4
Indoor Chemistry Modeling of Gas-, Particle-, and Surface-Phase Processes
Waring, M. S., & Shiraiwa, M. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_36 · Cited by 2
Mullen, N. A. (2011) · eScholarship (California Digital Library) · Cited by 3
Air filtration : predicting and improving indoor air quality and energy performance
Montgomery, J. (2015) · cIRcle (University of British Columbia) · doi:10.14288/1.0166381 · Cited by 2
Wang, C., & Li, X. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-024-33357-z · Cited by 1
Vivekanandan, N., & Rajeswari, K. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113867 · Cited by 1
Chen, M., Li, J., Li, S., Wang, X., & Gao, M. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.140800 · Cited by 2
Lin, C., Kikumoto, H., & Ooka, R. (2026) · Japan Architectural Review · doi:10.1002/2475-8876.70067 · Cited by 1
Analysis of Heavy Metal Compositions in Shah Alam Multi Storey House
Ismail, Z. S., Yasim, N. S. E. M., Mazlan, F. F., & Zaki, S. M. (2015) · Advanced materials research · doi:10.4028/www.scientific.net/amr.1113.759 · Cited by 1
A novel approach for the modelling of air quality dynamics in underground railway stations
Walther, É., & Bogdan, M. (2018) · International Journal of Environmental Impacts · doi:10.2495/ei-v1-n2-193-201 · Cited by 1
Din, S. A. M., Husin, N. B. M., & Othman, R. (2018) · PLANNING MALAYSIA · doi:10.21837/pmjournal.v16.i6.484 · Cited by 1
Tradeoffs between energy use and ventilation rates in U.S. Retail stores
Alhafi, Z., & Srebric, J. (2019) · Science and Technology for the Built Environment · doi:10.1080/23744731.2019.1693206 · Cited by 1
Sultan, Z., Li, J., Pantelic, J., & Schiavon, S. (2024) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.172126 · Cited by 1
Kumar, P., Omidvarborna, H., Kolluru, S. S. R., Kuye, A., Guler, Y., Kamigauti, L. Y., & Wu, H.-W. (2024) · Elsevier eBooks · doi:10.1016/b978-0-12-822591-2.00012-3 · Cited by 1
Hussein, T., & Kulmala, M. (2010) · Environmental pollution · doi:10.1007/978-90-481-8663-1_8 · Cited by 1
Medição, predição e análise de partículas aéreas em salas cirúrgicas.
Pereira, M. L. (2008) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.3.2008.tde-29012009-141031 · Cited by 9
The Impact of Plants on Indoor Air Quality, Energy Use, and Psychological Status of Occupants
Seyam, S. (2017) · TSpace (University of Toronto) · Cited by 2
(Re)scheduling Pollution Exposure: The Case of Surgery Schedules
Huang, J., Xing, J., & Zou, E. (2021) · National Bureau of Economic Research · doi:10.3386/w28708 · Cited by 1
Face-masks save us from SARS-CoV-2 transmissionPreprint
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.00375 · Cited by 2
Prediction of the concentration and diameter distribution of indoor suspended particulate matter
Liu, H., Li, C., & Li, L. (2009) · Kybernetes · doi:10.1108/03684920910944074
Rim, D. (2009) · Texas ScholarWorks (Texas Digital Library)
Stephens, B. R. (2012) · Texas ScholarWorks (Texas Digital Library)
Lunar Regolith Particles In Outposts
Lévy, F., Adams, C. M., & Petrov, G. (2009) · AIAA SPACE Conference & Exposition · doi:10.2514/6.2009-6585
Velagapudi, S. (2011) · OhioLink ETD Center (Ohio Library and Information Network)
The Effect of Building Construction and HVAC Systems on PM Concentration from Outdoor Sources
Alas, D. (2012) · UWSpace (University of Waterloo)
Energy Saving Strategies in Green Data Center Designing Based on Aerosol Corrosion Prevention
Ferrero, L., Sangiorgi, G., Perrone, M., Moscatelli, M., Angelo, L. D., Rovelli, G., Ariatta, A., & Bolzacchini, E. (2013) · Chemical engineering transactions · doi:10.3303/cet1332043
Surface interactions of aerosols and their impact on infectious disease transmission
You, S. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/61765
Kang, K., Kim, H., Lee, Y. G., & Kim, T. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/609/4/042105
Kabrein, A., & Ahmed, H. U. (2017) · UTHM Institutional Repository (Universiti Tun Hussein Onn Malaysia)
Chen, Z., Chen, C., Cao, G., Li, Z., Wu, Y. L., Cao, G., Yuan, Y., Li, X., & Hu, Q. (2020) · Environmental science and engineering · doi:10.1007/978-981-13-9520-8_17
Chen, C., & Zhao, B. (2020) · Environmental science and engineering · doi:10.1007/978-981-13-9520-8_43
Impact of Residential HVAC Filters on Particle Concentration and Exposure
Zhang, Y. (2020) · TSpace (University of Toronto)
Din, S. A. M., Husin, N. B. M., Othman, R., & Bagul, A. H. B. P. (2016) · The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Integrating Energy and Indoor Environmental Quality Retrofits in Apartments
Fisk, W. J. (2014) · eScholarship (California Digital Library)
Metadata
- Authors
- Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Riley, William J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-13
- Volume
- 36
- Issue
- 2
- Pages
- 200-207
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1973118576
- Cited by
- 417
- References
- 33
- Citations by year
- 2026: 8 · 2025: 11 · 2024: 11 · 2023: 10 · 2022: 23 · 2021: 22 · 2020: 29 · 2019: 22 · 2018: 25 · 2017: 21 · 2016: 19 · 2015: 32 · 2014: 27 · 2013: 18 · 2012: 26
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Keywords
- indoor particulate matter, particle size dependence, particle removal mechanism, particle deposition, ventilation filters, office buildings, residential buildings, ventilation rate, particle size distribution, sulfate, elemental carbon, indoor air quality, human exposure
- MeSH terms
- Air Movements, Air Pollutants, Environmental Exposure, Forecasting, Humans, Models, Theoretical, Particle Size, Public Health, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.