Indoor Particulate Matter of Outdoor Origin: Importance of Size-Dependent Removal Mechanisms
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Adverse human health effects have been observed to correlate with levels of outdoor particulate matter (PM), even though most human exposure to PM of outdoor origin occurs indoors. In this study, we apply a model and empirical data to explore the indoor PM levels of outdoor origin for two major building types: offices and residences. Typical ventilation rates for each building type are obtained from the literature. Published data are combined with theoretical analyses to develop representative particle penetration coefficients, deposition loss rates, and ventilation-system filter efficiencies for a broad particle size range (i.e., 0.001-10 microm). We apply archetypal outdoor number, surface area, and mass PM size distributions for both urban and rural airsheds. We also use data on mass-weighted size distributions for specific chemical constituents of PM: sulfate and elemental carbon. Predictions of the size-resolved indoor proportion of outdoor particles (IPOP) for various conditions and ambient particle distributions are then computed. The IPOP depends strongly on the ambient particle size distribution, building type and operational parameters, and PM metric. We conclude that an accurate determination of exposure to particles of ambient origin requires explicit consideration of how removal processes in buildings vary with particle size.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Riley et al. [10] suggested that the penetration of particles through building cracks would significantly affect indoor air quality, especially for buildings where air exchange through openings or cracks is dominated by pressure differences arising from natural forces.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [10]
Citations
Cites
Atmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Chemistry of the Upper and Lower Atmosphere: Theory, Experiments, and Applications
Finlayson‐Pitts, B. J., & PITTS, J. N. J. (1999) · Cited by 3,055
Uncertainty: A Guide to Dealing with Uncertainty in Quantitative Risk and Policy Analysis
Morgan, M. G., & Henrion, M. (1990) · Cambridge University Press eBooks · doi:10.1017/cbo9780511840609 · Cited by 1,711
Is Daily Mortality Associated Specifically with Fine Particles?
Schwartz, J., Dockery, D. W., & Neas, L. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467528 · Cited by 1,561
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Air pollution and incidence of cardiac arrhythmia
Peters, A., Liu, E., Verrier, R. L., Schwartz, J., Gold, D. R., Mittleman, M., Baliff, J., Oh, J. A., Allen, G., Monahan, K., et al. (2000) · Epidemiology · doi:10.1097/00001648-200001000-00005 · Cited by 651
Activity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Radon and its decay products in indoor air
Benarie, M. (1989) · Science of The Total Environment · doi:10.1016/0048-9697(89)90061-2 · Cited by 402
Jones, N. C., Thornton, C. A., Mark, D., & Harrison, R. M. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00489-6 · Cited by 374
Research works printed but not linked: 15
- Klemm R. J., 2000, J. Air Waste Manage. Assoc., 50, 1222
- Pope C. A., 1999, Am. Heart J., 138, 899
- Klepeis N. E., 2001, J. Exposure Anal. Environ. Epidemiol., 11, 252
- Lioy P. J., 1988, Arch. Environ. Health, 43, 312
- Yocum J. E., 1982, JAPCA, 32, 520
- Ozkaynak H., 1996, J. Exposure Anal. Environ. Epidemiol., 6, 78
- Long C. M., 2001, Environ. Sci. Technol., 35, 2099
- Abt E., 2000, Environ. Sci. Technol., 34, 3587
- Persily A., 1989, IAQ '89 Conference
- ASHRAE., 1993, ASHRAE Handbook: Fundamentals
- Xu M. D., 1994, Aerosol Sci. Technol., 20, 206
- Fogh C. L., 1997, Atmos. Environ., 31, 2203
- Liu D., 2001, Atmos. Environ., 35, 4462
- Whitby K. T., 1978, Atmos. Environ., 12, 159
- Ott W., 2000, J. Air Waste Manage. Assoc., 50, 1406
Cited by
Items 401–417 of 417
(Re)Scheduling Pollution Exposure: The Case of Surgery SchedulesPreprint
Huang, J., Xing, J., & Zou, E. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4012869
Interaction Between Gas-Phase Pollutants and Particles
Cao, J. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_12-1
Din, S. A. M., Husin, N. B. M., & Othman, R. (2018) · PLANNING MALAYSIA · doi:10.21837/pm.v16i6.484
Indoor Chemistry Modeling of Gas-, Particle-, and Surface-Phase Processes
Waring, M. S., & Shiraiwa, M. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_36-1
Interaction Between Gas-Phase Pollutants and Particles
Cao, J. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_12
Ma, X., Kim, W., Lee, J.-H., Han, D., Lee, S.-H., Kim, J., Lee, D., Kim, B., & Shin, D. (2023) · Bioengineering · doi:10.3390/bioengineering10080947
Delgado-Saborit, J. M. (2023) · Toxicology Letters · doi:10.1016/s0378-4274(23)00409-5
Xie, Y., Lao, C., Zhao, B., & Duan, X. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4575768
Mandal, D., Chakraborty, A., & Parkar, V. (2026) · Research Square · doi:10.21203/rs.3.rs-8473668/v1
Experimentally validated CFD–URANS study of portable air purifier performance in a classroom
Hafizović, M., Hadžiabdić, M., Mašić, A., & Ničeno, B. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114757
Lu, Q.-O., Chang, W., Chen, H. I., & Lee, C.-C. (2026) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2026.148595
Adaji, M. U., & Adekunle, T. O. (2026) · Journal of Physics Conference Series · doi:10.1088/1742-6596/3302/1/012080
R, D. M. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7641926
Chatziprodromidou, I. P., Fokas, R., Chatziantoniou, A., Koukouvini, K.-A., Karatzas, S. K., & Vantarakis, A. (2026) · Toxics · doi:10.3390/toxics14110937
Metadata
- Authors
- Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Riley, William J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-13
- Volume
- 36
- Issue
- 2
- Pages
- 200-207
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1973118576
- Cited by
- 417
- References
- 33
- Citations by year
- 2026: 8 · 2025: 11 · 2024: 11 · 2023: 10 · 2022: 23 · 2021: 22 · 2020: 29 · 2019: 22 · 2018: 25 · 2017: 21 · 2016: 19 · 2015: 32 · 2014: 27 · 2013: 18 · 2012: 26
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Keywords
- indoor particulate matter, particle size dependence, particle removal mechanism, particle deposition, ventilation filters, office buildings, residential buildings, ventilation rate, particle size distribution, sulfate, elemental carbon, indoor air quality, human exposure
- MeSH terms
- Air Movements, Air Pollutants, Environmental Exposure, Forecasting, Humans, Models, Theoretical, Particle Size, Public Health, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.