The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Development of a Set of Simple Bacterial Biosensors for Quantitative and Rapid Measurements of Arsenite and Arsenate in Potable Water
Abstract
Testing for arsenic pollution is commonly performed with chemical test kits of unsatisfying accuracy. Bacterial biosensors are an interesting alternative as they are easily produced, simple, and highly accurate devices. Here, we describe the development of a set of bacterial biosensors based on a nonpathogenic laboratory strain of Escherichia coli, the natural resistance mechanism of E. coli against arsenite and arsenate, and three reporter proteins: bacterial luciferase, beta-galactosidase and Green Fluorescent Protein (GFP). The biosensors were genetically optimized to reduce background expression in the absence of arsenic. In calibration experiments with the biosensors and arsenite-amended potable water, arsenite concentrations at 4 microg of As/L (0.05 microM) were routinely and accurately measured. The currently most quantitative system expressed the bacterial luciferase as reporter protein, responding proportional with a concentration range between 8 and 80 microg of As/L. Sensor cells could be stored as frozen batches, resuspended in plain media, and exposed to the aqueous test sample, and light emission was measured after 30-min incubation. Field testing for arsenite was achieved with a system that contained beta-galactosidase, producing a visible blue color at arsenite concentrations above 8 microg/L. For this sensor, a protocol was developed in which the sensor cells were dried on a paper strip and placed in the aqueous test solution for 30 min after which time color development was allowed to take place. The GFP sensor showed good potential for continuous rather than end point measurements. In all cases, growth of the biosensors and production of the strip test was achieved by very simple means with common growth media, and quality control of the sensors was performed by isolating the respective plasmids with the genetic constructs according to simple standard genetic technologies. Therefore, the biosensor cells and protocols may offer a realistic alternative for measuring arsenic contamination in potable water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular cloning: A laboratory manual
Deininger, P. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90595-z · Cited by 84,682
Worldwide Occurrences of Arsenic in Ground Water
Nordstrom, D. K. (2002) · Science · doi:10.1126/science.1072375 · Cited by 1,622
Arsenic poisoning of Bangladesh groundwater
Nickson, R., McArthur, J., Burgess, W., Ahmed, K. M., Ravenscroft, P., & Rahmanñ, M. (1998) · Nature · doi:10.1038/26387 · Cited by 1,476
Arsenic contamination of groundwater in Bangladesh
Kinniburgh, D. G., & Smedley, P. L. (2001) · Cited by 981
Arsenic in the geosphere — a review
Matschullat, J. (2000) · Science of The Total Environment · doi:10.1016/s0048-9697(99)00524-0 · Cited by 891
Arsenic: exposure and health effects
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5073 · Cited by 799
Improved gfp and inaZ Broad-Host-Range Promoter-Probe Vectors
Miller, W. G., Leveau, J. H. J., & Lindow, S. E. (2000) · Molecular Plant-Microbe Interactions® · doi:10.1094/mpmi.2000.13.11.1243 · Cited by 557
Daunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith-Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 445
Self-citationThe ars operon of Escherichia coli confers arsenical and antimonial resistance
Carlin, A., Shi, W., Dey, S., & Rosen, B. P. (1995) · Journal of Bacteriology · doi:10.1128/jb.177.4.981-986.1995 · Cited by 394
Rahman, M. M., Mukherjee, D., Sengupta, M. K., Chowdhury, U. K., Lodh, D., Chanda, C. R., Roy, S., Selim, M., Quamruzzaman, Q., Milton, A. H., et al. (2002) · Environmental Science & Technology · doi:10.1021/es020591o · Cited by 205
Cited by
Where microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Self-citationA sensing array of radically coupled genetic ‘biopixels’
Prindle, A., Samayoa, P., Razinkov, I., Danino, T., Tsimring, L. S., & Hasty, J. (2012) · Nature · doi:10.1038/nature10722 · Cited by 397
Gui, Q., Lawson, T., Shan, S., Yan, L., & Liu, Y. (2017) · Sensors · doi:10.3390/s17071623 · Cited by 347
Applications of whole-cell bacterial sensors in biotechnology and environmental science
Yagi, K. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0718-6 · Cited by 254
Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
Wlodkowic, D., & Karpiński, T. M. (2021) · Sensors · doi:10.3390/s21217028 · Cited by 28
Metadata
- Authors
- Stocker, J., Balluch, D., Gsell, M., Harms, H., Feliciano, J., Daunert, S., Malik, K. A., & van der Meer, J. R.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-17
- Volume
- 37
- Issue
- 20
- Pages
- 4743-4750
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2045442804
- Cited by
- 331
- References
- 16
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.