Relative Contribution of Outdoor and Indoor Particle Sources to Indoor Concentrations
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The effect of indoor particle sources on indoor particle size distributions and concentrations was previously investigated using real-time indoor and outdoor particle size distribution data collected in four homes in Boston in 1996. These data demonstrated the importance of indoor sources (i.e., cooking, cleaning, and movement of people) and air exchange rates on observed indoor concentrations. As part of the continued analyses of these data, a simple physical model was used to determine the source emission and infiltration rates for specific particle sizes. Decay rates were also estimated. Cooking, cleaning, and indoor work (characterized by movement of people) significantly increased PM (0.7 - 10) concentrations by 0.27, 0.27, and 0.25 μm 3 cm - 3 min - 1, respectively. Cooking was the only variable significantly associated with generation of particles less than 0.5 μm in diameter. Outdoor particles (0.02−0.5 and 0.7−10 μm) were found to contribute significantly to indoor particle levels. Effective penetration efficiencies ranged from 0.38 to 0.94 for 0.02−0.5 μm particles and from 0.12 to 0.53 for 0.7−10 μm particles. Estimates for 0.7−10 μm particles decreased with increasing particle size, reflecting the influence of deposition losses from gravitational settling. The real-time particle size distribution data in conjunction with time−activity information provides valuable information on the origin and fate of indoor particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Abt et al. [12] found that cleaning activities and the movement of people significantly increased PM (0.7-10) concentrations by 0.27 µm 3 /cm 3 and 0.25 µm 3 /cm 3 , respectively, per minute in domestic buildings in Boston.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [12]
Citations
Cites
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Özkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Atmospheric Chemistry: Fundamentals and Experimental Techniques
Ronneau, C. (1987) · Eos, Transactions American Geophysical Union · doi:10.1029/eo068i049p01643-01 · Cited by 381
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Self-citationSource apportionment of indoor aerosols in Suffolk and Onondaga counties, New York
Koutrakis, P., Briggs, S. L. K., & Leaderer, B. P. (1992) · Environmental Science & Technology · doi:10.1021/es00027a012 · Cited by 184
Self-citationA study of characterize indoor particles in three non-smoking homes
Kamens, R. M., Lee, C.-T., Wiener, R. W., & Leith, D. E. (1991) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(91)90136-u · Cited by 139
Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles
Raunemaa, T. M., Kulmala, M., Saari, H., Olin, M., & Kulmala, M. H. (1989) · Aerosol Science and Technology · doi:10.1080/02786828908959296 · Cited by 96
Modeling of Indoor Air Quality and Exposure
Nagda, N. L. (1993) · doi:10.1520/stp1205-eb · Cited by 71
The relationship between airborne acidity and ammonia in indoor environments.
Suh, H. H., Koutrakis, P., & Spengler, J. D. (1994) · PubMed · Cited by 51
Self-citation
Research works printed but not linked: 6
- Wallace, L.; Quackenboss, J.; Rhodes, C. InAWMA/EPA Symposium on the Measurement of Toxic and Related Air Pollutants; Research Triangle Park, NC, 1997; pp 860−871.
- Özkaynak H., The Particle TEAM (PTEAM) Study: Analysis of the Data−Final Report, 1994
- Özkaynak H., 1996, J. Exp. Anal. Environ. Epidemiol, 6, 57
- Brüel, 1990, Instruction Manual for the Multi-Gas Monitor Type 1302
- Suh H. H., 1994, J. Exp. Anal. Environ. Epidemiol, 4, 1
- Milford J. B., 1987, J. Air Pollut. Control Assoc, 37, 125
Cited by
Items 201–300 of 419
Chithra, V. S., & Nagendra, S. M. S. (2014) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2014.894483 · Cited by 33
“Many previous PM size distribution studies conducted in indoor environments also reported an increase in fine particles with outdoor traffic and increase in coarse mode particles with occupant activities (Eileen et al., 2000; Tippayawong et al., 2009; Guo et al., 2010).”
BackgroundBozlaker, A., Peccia, J., & Chellam, S. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.6b06252 · Cited by 32
Sun, L., Wallace, L. A., Dobbin, N. A., You, H., Kulka, R., Shin, T., St-Jean, M., Aubin, D., & Singer, B. C. (2018) · Aerosol Science and Technology · doi:10.1080/02786826.2018.1524572 · Cited by 31
“Although the results of chamber studies (e.g. Nomura et al. 1997; Thatcher et al. 2002) and some real house studies (e.g. Fogh et al.1997; Abt et al. 2000; Long et al. 2001) have indicated that there is a positive correlation between air exchange rate and particle deposition rate, inconsistent…”
ResultOmelekhina, Y., Eriksson, A. C., Canonaco, F., Prévôt, A. S. H., Nilsson, P. T., Isaxon, C., Pagels, J., & Wierzbicka, A. (2020) · Environmental Science Processes & Impacts · doi:10.1039/d0em00061b · Cited by 36
Short-term dynamic patterns of bioaerosol generation and displacement in an indoor environment
Brandl, H., von Däniken, A., Hitz, C., & Krebs, W. (2008) · Aerobiologia · doi:10.1007/s10453-008-9099-x · Cited by 31
“Diurnal variations have been observed; these were correlated with human activity (Morawska et al. 2003; Abt et al. 2000).”
BackgroundInfluentialInhalational exposure to heavy metals: Carcinogenic and non-carcinogenic risk assessment
Khoshakhlagh, A. H., Ghobakhloo, S., & Gruszecka‐Kosowska, A. (2024) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2024.100485 · Cited by 30
The contribution of outdoor particulate matter (PM 1 , PM 2.5 , PM 10 ) to school indoor environment
Zwoździak, A., Sówka, I., Worobiec, A., Zwoździak, J., & Nych, A. (2014) · Indoor and Built Environment · doi:10.1177/1420326x14534093 · Cited by 31
Vertical monitoring of traffic-related air pollution (TRAP) in urban street canyons of Hong Kong
Wong, P. P. Y., Lai, P., Allen, R. W., Cheng, W., Lee, M., Tsui, A., Tang, R., Thach, T., Tian, L., Brauer, M. D., et al. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.03.224 · Cited by 31
Daher, N., Ruprecht, A., Invernizzi, G., Marco, C. D., Miller-Schulze, J. P., Heo, J. B., Shafer, M. M., Schauer, J. J., & Sioutas, C. (2011) · Environmental Science & Technology · doi:10.1021/es202736a · Cited by 34
Residential indoor and outdoor coarse particles and associated endotoxin exposures
Wheeler, A. J., Dobbin, N. A., Lyrette, N., Wallace, L. A., Foto, M., Mallick, R., Kearney, J. P., Ryswyk, K. V., Gilbert, N. L., Harrison, I., et al. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.09.048 · Cited by 29
“This corresponds to other studies which have identified similar predictors for indoor coarse particles (Abt et al., 2000; Long et al., 2000; Wallace and HowardReed, 2002; Rojas-Bracho et al., 2000; Chen and Hildemann, 2009).”
BackgroundResultMcAuley, T. R., Fisher, R., Zhou, X., Jaques, P. A., & Ferro, A. R. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00654.x · Cited by 36
Li, Z., Liu, G., Shen, M., Hu, R., & Liu, Y. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135599 · Cited by 28
Qiu, Y., Wang, Y., & Ya, T. (2020) · Building Simulation · doi:10.1007/s12273-020-0663-9 · Cited by 28
Ten questions concerning indoor ultrafine particles
Nazaroff, W. W. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110641 · Cited by 31
Effects of climate change on residential infiltration and air pollution exposure
Ilacqua, V. A., Dawson, J. P., Breen, M. S., Singer, S., & Berg, A. (2015) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2015.38 · Cited by 28
LIAO, C., & LUO, W. (2005) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2004.12.036 · Cited by 28
“We employed a well-developed indoor/outdoor ratio model (Abt et al., 2000; Riley et al., 2002; Liao et al., 2003) to calculate the uncorrelated size-specific, time-averaged airborne fungal concentrations I/O ratio,”
MethodOr, V. W., Wade, M., Patel, S., Alves, M. R., Kim, D., Schwab, S., Przelomski, H., O’Brien, R. E., Rim, D., Corsi, R. L., et al. (2020) · Environmental Science Processes & Impacts · doi:10.1039/d0em00156b · Cited by 33
Lee, W.-C., Wolfson, J. M., Catalano, P. J., Rudnick, S. N., & Koutrakis, P. (2014) · Environmental Science & Technology · doi:10.1021/es502278k · Cited by 27
Self-citationUltrafine particles from a vented gas clothes dryer
Wallace, L. A. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.03.050 · Cited by 27
Exposure to particulate matter in a mosque
Ocak, Y., Kılıçvuran, A., Eren, A. B., Sofuoǧlu, A., & Sofuoǧlu, S. C. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.04.007 · Cited by 29
Zhong, K., Yang, F., & Kang, Y. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.01.010 · Cited by 28
Kim, J., Kong, M., Hong, T., Jeong, K., & Lee, M. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.12.054 · Cited by 27
Gao, P., Lei, T., Jia, L., Song, Y., Xing, Y., Zhang, Z., Yu, D., Feng, Y., & Xing, B. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.08.138 · Cited by 25
Chang, L.-T., Koutrakis, P., Catalano, P. J., & Suh, H. H. (2003) · Journal of Toxicology and Environmental Health · doi:10.1080/15287390306431 · Cited by 25
Self-citationKuhlbusch, T. A. J. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00489-1 · Cited by 25
Particulate matter concentrations in social housing
Mendell, A. Y., Mahdavi, A., & Siegel, J. A. (2021) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.103503 · Cited by 25
Mei, X., Zeng, C., & Gong, G. (2021) · Building Simulation · doi:10.1007/s12273-021-0855-y · Cited by 24
“In particular, particles generated by indoor sources including tobacco smoke and cooking activities can make a substantial contribution to adverse effects on occupants (Abt et al. 2000; Wang et al. 2020).”
BackgroundAn Experimental Investigation of the Flowfield and Dust Resuspension Due to Idealized Human Walking
Kubota, Y., Hall, J. W., & Higuchi, H. (2009) · Journal of Fluids Engineering · doi:10.1115/1.3176962 · Cited by 24
HVAC air-quality model and its use to test a PM2.5 control strategy
Marsik, T., & Johnson, R. (2007) · Building and Environment · doi:10.1016/j.buildenv.2007.11.001 · Cited by 24
Sturm, R. (2011) · Thoracic Cancer · doi:10.1111/j.1759-7714.2011.00042.x · Cited by 23
Indoor particulate matter in urban residences of Alexandria, Egypt
Abdel-Salam, M. M. M. (2013) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2013.801374 · Cited by 23
“Recently, there has been an increasing interest towards the estimation of the contribution of outdoor particles to the indoor particle concentration levels (Abt et al., 2000; Morawska et al., 2001; Cyrys et al., 2004; Hoek et al., 2008; Abdel-Salam, 2012).”
BackgroundXiao, Y., Wang, L., Yu, M., Liu, H., & Liu, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.001 · Cited by 24
Sippula, O., Rintala, H., Happo, M. S., Jalava, P., Kuuspalo, K., Virén, A., Leskinen, A., Markkanen, A., Komppula, M., Markkanen, P. M. H., et al. (2013) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.11.0300 · Cited by 26
“Coarse particles are easily filtrated or become deposited on surfaces during the house air intake while fine particles have a high infiltration rate (Abt et al. , 2000; Jones et al. , 2000).”
Association of size-resolved airborne particles with foot traffic inside a carpeted hallway
Cheng, K.-C., Goebes, M. D., & Hildemann, L. M. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.02.027 · Cited by 21
“This result agrees with previous findings that particle resuspension due to indoor walking activities was most pronounced for supermicron particles (Thatcher and Layton, 1995; Abt et al., 2000; Long et al., 2000; Ferro et al., 2004b).”
ResultCharacterization of the indoor particles and their sources in an Antarctic research station
Pagel, É. C., Reis, N. C., de Alvarez, C. E., Santos, J. M., Conti, M. M., Boldrini, R. S., & Kerr, A. S. (2016) · Environmental Monitoring and Assessment · doi:10.1007/s10661-016-5172-z · Cited by 22
“…that other human activities, such as cleaning and people movement, tend to be very important for particle emission, since these activities have a tendency to generate particles greater than 1 μm, as already demonstrated by earlier studies, such as Abt et al. (2000) and McDonagh and Byrne (2014).”
BackgroundMaragkidou, A., Al-Jaghbeer, O., Hämeri, K. J., & Hussein, T. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.05.031 · Cited by 21
Park, S., Song, D., Seung-Hwan, P., & Choi, Y. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-01047-1 · Cited by 21
“…exchange rate and deposition rate, and several previous studies discuss the use of this equation for the determination of the particle decay rate (Abt et al. 2000; Howard-Reed et al. 2003; Kang et al. 2019). ln Cin;t=Cin;0 ¼ −K∙t ð4Þ Calculation of clean air delivery rate (CADR) The US…”
BackgroundMethodLiao, C., Huang, S.-J., & Yu, H. (2003) · Building and Environment · doi:10.1016/j.buildenv.2003.09.015 · Cited by 21
“Indoor sources such as environmental tobacco smoke, cooking, and cleaning activities can contribute signi5cantly to indoor PM levels in that these indoor sources require a further research to characterize their e9ects [20,21].”
BackgroundJanney, J. B., Harish, C., Lawrence, C. C., Krishnakumar, S., Divakaran, S., Premkumar, J., Prince, P. G. K., Sabarivani, A., & Jagadeesan, A. K. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-24117-y · Cited by 20
“Therefore, air pollutant exposure in indoor environments can be higher than in outdoor environments (Abt et al. 2000).”
BackgroundResidential indoor and personal PM10 exposures of ambient origin based on chemical components
Xu, J., Bai, Z., You, Y., Zhou, J., Zhang, J., Niu, C., Liu, Y., Zhang, N., He, F., & Ding, X. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2014.28 · Cited by 20
Shehab, M., Pope, F. D., & Delgado-Saborit, J. M. (2021) · Journal of Environmental Health Science and Engineering · doi:10.1007/s40201-020-00604-7 · Cited by 21
Bennett, D. H., Moran, R. E., Krakowiak, P., Tancredi, D. J., Kenyon, N. J., Williams, J., & Fisk, W. J. (2022) · Indoor Air · doi:10.1111/ina.12982 · Cited by 20
Lee, W.-C., Catalano, P. J., Yoo, J. Y., Park, C. J., & Koutrakis, P. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03126 · Cited by 20
Self-citationAnalysis of vertical movement of particulate matter due to the stack effect in high-rise buildings
Park, S., Yun, C., Lim, H., & Song, D. (2022) · Atmospheric Environment · doi:10.1016/j.atmosenv.2022.119113 · Cited by 19
Park, S.-Y., Yoon, D.-K., Park, S., Jeon, J.-I., Lee, J.-M., Yang, W., Cho, Y.-S., Kwon, J., & Lee, C.-M. (2023) · Toxics · doi:10.3390/toxics11060526 · Cited by 19
Marsik, T., & Johnson, R. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.02.007 · Cited by 19
Air Pollution: Concepts, Theory, and Applications
Seigneur, C. (2019) · Cited by 19
Stratigou, E., Dusanter, S., de Brito, J. F., & Riffault, V. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107357 · Cited by 19
Window purifying ventilator using a cross-flow fan: Simulation and optimization
Li, J., Hou, Y., Liu, J., Wang, Z., & Li, F. (2016) · Building Simulation · doi:10.1007/s12273-016-0281-8 · Cited by 21
Colbeck, I., & Nasir, Z. A. (2010) · Environmental pollution · doi:10.1007/978-90-481-8663-1_2 · Cited by 20
“…Raunemaa et al. 1989; Long et al. 2000; Dennekamp et al. 2001; Sjaastad and Svendsen 2008) while sources such as cleaning, dusting and vacuuming, showering, electric motors, movement of people and gas-to-particle conversion have also been investigated (e.g. Abt et al. 2000a, b; Waring et al. 2008).”
BackgroundRose, O. G., Bousiotis, D., Rathbone, C., & Pope, F. D. (2024) · Indoor Air · doi:10.1155/2024/5544298 · Cited by 18
Hu, Y.-J., Bao, L., Huang, C.-L., Li, S., Liu, P., & Zeng, E. Y. (2018) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.08.025 · Cited by 18
Zhang, Y., Li, T., & Siegel, J. A. (2020) · Science and Technology for the Built Environment · doi:10.1080/23744731.2020.1778402 · Cited by 18
“…in all the homes were positively skewed, indicating that the indoor concentrations were potentially elevated by common indoor particle generation activities such as cooking, cleaning, or movement of people, which has been reported in other studies (e.g., Abt et al. 2000; Bhangar et al. 2011).”
BackgroundResultAn assessment of indoor air quality in recent Mexican immigrant housing in Commerce City, Colorado
Miller, S. L., Scaramella, P., Campe, J., Goss, C. W., Diaz-Castillo, S., Hendrikson, E., DiGuiseppi, C. G., & Litt, J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.07.037 · Cited by 20
Eom, Y. S., Park, B. R., Shin, H. W., & Kang, D. H. (2021) · Sustainability · doi:10.3390/su13137382 · Cited by 17
“[20] reported that 20–43% of indoor particles of 2–10 μm size and 63–92% of indoor particles of 0.”
BackgroundImpact of ironing on indoor particle levels and composition
Vicente, E. D., Evtyugina, M. G., Vicente, A., Calvo, A., Oduber, F., Blanco‐Alegre, C., Castro, A., Fraile, R., Nunes, T., Lucarelli, F., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107636 · Cited by 20
Characterization of Indoor and Outdoor Aerosols in a Suburban Area of Prague
Smolík, J., Dohányosová, P., Schwarz, J., Ždímal, V., & Lazaridis, M. (2007) · Water Air and Soil Pollution Focus · doi:10.1007/s11267-007-9141-y · Cited by 17
Ge, H. M., Yamazaki, E., Yamashita, N., Taniyasu, S., Zhang, T., Hata, M., & Furuuchi, M. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.07.0292 · Cited by 19
Effect of Occupant Activity on Indoor Particle Concentrations in Korean Residential Buildings
Kim, H., Kang, K., & Kim, T. (2020) · Sustainability · doi:10.3390/su12219201 · Cited by 17
“The analysis concluded that indoor fine particle concentration is affected in combination with indoor and outdoor sources [31].”
Segalin, B., Fornaro, A., Kumar, P., Klemm, O., Andrade, M. D. F., Trezza, B. M., Busse, A. L., Filho, W. J., & Gonçalves, F. L. T. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2019.09.0462 · Cited by 17
“Certainly, outdoor air is also a source for indoor PM, which holds especially for qUFP and UFP because they can best penetrate the natural and artificial ventilation systems (Abt et al. , 2000).”
Effect of Flow Rate and Filter Efficiency on Indoor PM2.5 in Ventilation and Filtration Control
Kim, J., & Yeo, M.-S. (2020) · Atmosphere · doi:10.3390/atmos11101061 · Cited by 16
Liao, C., Chen, J.-W., & Huang, S.-J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(03)00291-7 · Cited by 16
“Thatcher and Layton (1995); Abt et al. (2000) ; Riley et al. (2002) have developed rigorous indoor air quality models for studying the PM I/O relationships and sizedependent removal mechanisms in a residence, in which the model employed by them applied also to our study.”
MethodAlotaibi, S., Chakroun, W. M., Habchi, C., Ghali, K., & Ghaddar, N. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100855 · Cited by 17
Geographic differences in inter-individual variability of human exposure to fine particulate matter
Cao, Y., & Frey, H. C. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.07.034 · Cited by 15
“The highest mean value of ACH was observed in the winter and the lowest in the summer, a reversal of the typical pattern in other studies (Abt et al., 2000; Long et al., 2001).”
ResultIndoor Dose Conversion Coefficients for Radon Progeny for Different Ambient Environments
Yu, K. N., Wong, B. T. Y., Law, J. Y. P., Lau, B. M. F., & Nikezic, D. R. (2001) · Environmental Science & Technology · doi:10.1021/es001920k · Cited by 15
Bathula, S., Anand, S., Thajudeen, T., Mayya, Y. S., Chaudhury, P., & Shashank, C. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200547 · Cited by 15
“In the singlecompartment indoor model, it is assumed that the indoor pollutants/aerosols are uniformly distributed inside the whole room volume instantaneously, irrespective of the mixing and ventilation rates (Abt et al., 2000; Mosley et al., 2001; Thornburg et al., 2001; Riley et al., 2002; Asmi et al., 2004; Jamris…”
BackgroundHe, R., Zhang, J., & Mainelis, G. (2022) · Indoor Air · doi:10.1111/ina.13157 · Cited by 15
Social indicators are predictors of airborne outdoor exposures in Berlin
Franck, U. F., Klimeczek, H.-J., & Kindler, A. (2013) · Ecological Indicators · doi:10.1016/j.ecolind.2013.08.023 · Cited by 14
Davenport, J. J., Hodgkinson, J., Saffell, J. R., & Tatam, R. P. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/27/1/015802 · Cited by 14
“The concentrations of many airborne particles are decreasing due to legal restrictions on certain sources, but it is difficult to draw general trends [27, 49, 50].”
BackgroundSagona, J. A., Shalat, S. L., Wang, Z., Ramagopal, M., Black, K., Hernandez, M., & Mainelis, G. (2016) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.24 · Cited by 14
Chiesa, M. R., Urgnani, R., Marzuoli, R., Finco, A., & Gerosa, G. A. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106181 · Cited by 15
Blower-door estimates of PM 2.5 deposition rates and penetration factors in an idealized room
Lai, Y., Ridley, I. A., & Brimblecombe, P. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20944427 · Cited by 14
“Several previous studies have also applied this method.(9,32) The penetration factor (Pf) can be found from kCO2, v, ci and cout according to equation (4).”
BackgroundKazzaz, M., Habchi, C., Ghali, K., Ghaddar, N., Alotaibi, S., & Chakroun, W. M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.07.011 · Cited by 13
Feng, S., Miao, J., Wang, M., Jiang, N., Dou, S., Yang, L., Ma, Y., Yu, P., Ye, T., Wu, Y. Y., et al. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.158150 · Cited by 13
Park, S., Lee, S., Yeo, M.-S., & Rim, D. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110412 · Cited by 13
Fine Particulate Matter Exposure and Health Impacts from Indoor Activities
Bhoonah, R., Micolier, A., Jolliet, O., & Fantke, P. (2023) · Indoor Air · doi:10.1155/2023/8857446 · Cited by 13
“Since particle size distributions are only available for some speci fi c activities, we select a more general indoor distribution, irrespective of the emission source [39].”
BackgroundParticle characterization in retail environments: concentrations, sources, and removal mechanisms
Zaatari, M., & Siegel, J. A. (2013) · Indoor Air · doi:10.1111/ina.12088 · Cited by 13
Kim, J., Park, S., Kim, H., & Yeo, M.-S. (2017) · Indoor and Built Environment · doi:10.1177/1420326x17707565 · Cited by 13
“The penetration coefficient (Pj) was obtained using equation (13) with the previously determined AER ( ) and deposition rate (kj).”
BackgroundMethodINDOOR AND OUTDOOR AEROSOL PARTICLE SIZE CHARACTERIZATION IN HELSINKI
Hussein, T. (2005) · Työväentutkimus Vuosikirja · Cited by 13
Wang, Z., & Liu, J. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.06.003 · Cited by 12
Outdoor/Indoor Contaminant Transport by Atmospheric Dust and Aerosol at an Active Smelter Site
Rodríguez-Chávez, T. B., Rine, K. P., Almusawi, R. M., O’Brien-Metzger, R., Ramírez‐Andreotta, M. D., Betterton, E. A., & Sáez, A. E. (2021) · Water Air & Soil Pollution · doi:10.1007/s11270-021-05168-2 · Cited by 12
Mihailovic, D. T., Alapaty, K., & Podraščanin, Z. (2009) · Environmental Science and Pollution Research · doi:10.1007/s11356-008-0086-0 · Cited by 12
Optimizing indoor air models through k-means clustering of nanoparticle size distribution data
Cebolla-Alemany, J., Macarulla, M., Viana, M., Moreno-Martín, V., Sanfélix, V., & Bou, D. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112091 · Cited by 11
Estimating the Potential Health Benefits of Air Quality Warnings
Buonocore, J. J., Robinson, L. A., Hammitt, J. K., & O’Keeffe, L. (2020) · Risk Analysis · doi:10.1111/risa.13640 · Cited by 11
“5 For fine particles, recent reviews (Abt et al., 2000; Chen & Zhao, 2011; Diapouli, Chaloulakou, & Koutrakis, 2013) find infiltration ranging from 0 to 100% depending on the particle size, the size of the gap through which the particles travel, and the differences between air pressure indoors and outdoors.”
BackgroundInfluentialPeng, Z., Cheng, Y., Jiang, M., Shu, S., & Geng, X. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107065 · Cited by 11
Tang, Z., Hu, X., Qiao, J., & Lian, H. (2018) · Atmosphere · doi:10.3390/atmos9090340 · Cited by 11
Ouaret, R., Ionescu, A., & Ramalho, O. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108055 · Cited by 11
Improving Flow Patterns and Spillage Characteristics of a Box-Type Commercial Kitchen Hood
Huang, R. F., Chen, J., Han, M.-J., & Priyambodo, Y. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.858822 · Cited by 11
Analyses of human exposure to urban air quality in a children population
Garcia, J., Coelho, L., Gouveia, C. M., Cerdeira, R., Louro, C., Ferreira, T. M., & Baptista, M. N. A. (2010) · International Journal of Environment and Pollution · doi:10.1504/ijep.2010.030886 · Cited by 11
“There are several studies about indoor air quality, pollutant sources, concentrations and proposals to improve indoor air quality (Abt et al., 2000; Schneider et al., 2004).”
BackgroundIn-Field Ambient Fine Particle Monitoring of an Outdoor Wood Boiler: Public Health Concerns
Johnson, P. R. S. (2006) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807030600977202 · Cited by 11
“Studies have found that indoor fine particles are comprised from about an average of 20% to 80% of outdoor fine particles, depending on climate, building characteristics, and other factors (Abt et al. 2000; Allen et al. 2003; Dockery and Spengler 1981; Meng et al. 2005).”
BackgroundKamboj, S., Arnish, J. J., & Yu, C. (2002) · Cited by 11
Zhu, Y.-S., Yang, W.-D., Li, X., Ni, H., & Zeng, H. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.10.013 · Cited by 10
“…deposition, indoor source emission rate and removal efficiency of heating, ventilation and air condition systems and other mechanisms of aerosol particles (Abt et al., 2000; Bennett and Koutrakis, 2006; Li and Chen, 2003; Long et al., 2001; Thatcher and Layton, 1995; Thornburg et al., 2001).”
BackgroundMethodSimulation and evaluation of sheltering efficiency of houses equipped with ventilation systems
Wang, W., Kato, N., Kimoto, S., Matsui, Y., & Yoneda, M. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106491 · Cited by 10
Impact of air quality on students’ behavior in the Educational Centers
Oroji, B., Sadighzadeh, A., Solgi, E., & Oliaei, M. S. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-00979-y · Cited by 10
“Some studies done in this area by Oroji et al. (2018), Long et al. (2000, 2001), Deng et al. (2017), Li and Lin (2003), Funasaka et al. (2000), Abt et al. (2000), and Ramachandran et al. (2000) focused on particulate matter and its chemical characteristics, the contribution of indoor/outdoor…”
BackgroundInfluentialAir pollution and individual productivity: Evidence from the Ironman Triathlon results
Naidenova, I., Паршаков, П. А., & Suvorov, S. (2022) · Economics & Human Biology · doi:10.1016/j.ehb.2022.101159 · Cited by 10
Health effects of aerosols: Mechanisms and epidemiology
Tager, I. B. (2004) · CRC Press eBooks · doi:10.1201/9780203493182.ch24 · Cited by 10
Orola, B. A. (2020) · Sustainable buildings · doi:10.1051/sbuild/2020001 · Cited by 13
Elemental composition of indoor and outdoor coarse particulate matter at an inner-city high school
Williamson, K., Das, S., Ferro, A. R., & Chellam, S. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118559 · Cited by 10
REPORT TO THE CALIFORNIA LEGISLATURE
Orenstein, M. R., Gutiérrez, N. L., Rice, T., Cooper, J. F., & Ragland, D. R. (2007) · Cited by 10
An Assessment of Risk from Particulate Released from Outdoor Wood Boilers
Brown, D. R., Callahan, B. G., & Boissevain, A. L. (2007) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807030601105126 · Cited by 12
“Assessing potential indoor exposures using a box model5 Exposures to indoor air, infiltrated by PM-contaminated “fresh air” will add to a person’s total exposure; therefore the importance of indoor exposures should not be overlooked (Abt et al. 2000; Meng et al. 2005; Molnár et al. 2005).”
BackgroundMethod
Metadata
- Authors
- Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P.
- Affiliations
- Harvard University (US)
- Corresponding author
- Abt, Eileen
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-02
- Volume
- 34
- Issue
- 17
- Pages
- 3579-3587
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2068336202
- Cited by
- 411
- References
- 17
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 15 · 2021: 29 · 2020: 23 · 2019: 18 · 2018: 19 · 2017: 11 · 2016: 16 · 2015: 29 · 2014: 21 · 2013: 22 · 2012: 19
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air pollution, particulate matter, cooking emissions, indoor work, air exchange rate, penetration efficiency, particle size distribution, particle decay rates, gravitational settling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.