Relative Contribution of Outdoor and Indoor Particle Sources to Indoor Concentrations
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The effect of indoor particle sources on indoor particle size distributions and concentrations was previously investigated using real-time indoor and outdoor particle size distribution data collected in four homes in Boston in 1996. These data demonstrated the importance of indoor sources (i.e., cooking, cleaning, and movement of people) and air exchange rates on observed indoor concentrations. As part of the continued analyses of these data, a simple physical model was used to determine the source emission and infiltration rates for specific particle sizes. Decay rates were also estimated. Cooking, cleaning, and indoor work (characterized by movement of people) significantly increased PM (0.7 - 10) concentrations by 0.27, 0.27, and 0.25 μm 3 cm - 3 min - 1, respectively. Cooking was the only variable significantly associated with generation of particles less than 0.5 μm in diameter. Outdoor particles (0.02−0.5 and 0.7−10 μm) were found to contribute significantly to indoor particle levels. Effective penetration efficiencies ranged from 0.38 to 0.94 for 0.02−0.5 μm particles and from 0.12 to 0.53 for 0.7−10 μm particles. Estimates for 0.7−10 μm particles decreased with increasing particle size, reflecting the influence of deposition losses from gravitational settling. The real-time particle size distribution data in conjunction with time−activity information provides valuable information on the origin and fate of indoor particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Abt et al. [12] found that cleaning activities and the movement of people significantly increased PM (0.7-10) concentrations by 0.27 µm 3 /cm 3 and 0.25 µm 3 /cm 3 , respectively, per minute in domestic buildings in Boston.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [12]
Citations
Cites
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Özkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Atmospheric Chemistry: Fundamentals and Experimental Techniques
Ronneau, C. (1987) · Eos, Transactions American Geophysical Union · doi:10.1029/eo068i049p01643-01 · Cited by 381
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Self-citationSource apportionment of indoor aerosols in Suffolk and Onondaga counties, New York
Koutrakis, P., Briggs, S. L. K., & Leaderer, B. P. (1992) · Environmental Science & Technology · doi:10.1021/es00027a012 · Cited by 184
Self-citationA study of characterize indoor particles in three non-smoking homes
Kamens, R. M., Lee, C.-T., Wiener, R. W., & Leith, D. E. (1991) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(91)90136-u · Cited by 139
Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles
Raunemaa, T. M., Kulmala, M., Saari, H., Olin, M., & Kulmala, M. H. (1989) · Aerosol Science and Technology · doi:10.1080/02786828908959296 · Cited by 96
Modeling of Indoor Air Quality and Exposure
Nagda, N. L. (1993) · doi:10.1520/stp1205-eb · Cited by 71
The relationship between airborne acidity and ammonia in indoor environments.
Suh, H. H., Koutrakis, P., & Spengler, J. D. (1994) · PubMed · Cited by 51
Self-citation
Research works printed but not linked: 6
- Wallace, L.; Quackenboss, J.; Rhodes, C. InAWMA/EPA Symposium on the Measurement of Toxic and Related Air Pollutants; Research Triangle Park, NC, 1997; pp 860−871.
- Özkaynak H., The Particle TEAM (PTEAM) Study: Analysis of the Data−Final Report, 1994
- Özkaynak H., 1996, J. Exp. Anal. Environ. Epidemiol, 6, 57
- Brüel, 1990, Instruction Manual for the Multi-Gas Monitor Type 1302
- Suh H. H., 1994, J. Exp. Anal. Environ. Epidemiol, 4, 1
- Milford J. B., 1987, J. Air Pollut. Control Assoc, 37, 125
Cited by
Items 301–400 of 419
Chemical composition of indoor and outdoor PM2.5 in the eastern Arabian Peninsula
Tutsak, E., Alföldy, B., Mahfouz, M. M. K., Al-Thani, J. A., Yiğiterhan, O., Shahid, I., Isaifan, R. J., & Koçak, M. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-024-34482-5 · Cited by 9
“This may be attributed to the resuspension of the particles from the floor surfaces due to active human activities such as walking and vacuum cleaning (Abt et al. 2000; Wang et al. 2021).”
BackgroundWu, X., Yue, F., Wang, J., Yu, X., Liu, H., Gu, W., Han, M., Li, J., & Xie, Z. (2022) · Journal of Environmental Sciences · doi:10.1016/j.jes.2022.04.045 · Cited by 9
Liang, C.-Y., Hsu, P.-T., Yuan, M.-H., Chen, Y., Chang, C.-M., Chang, C.-Y., Chou, S.-C., & Liang, C. (2022) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2022.06.054 · Cited by 9
Research on an adaptive prediction method for restaurant air quality based on occupancy detection
Zhao, Y., Xiong, C., Rong, L., Luo, Z., Hussein, T., & Zhao, T. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112145 · Cited by 12
Measuring Ambient Acidic Ultrafine Particles Using Iron Nanofilm Detectors: Method Development
Wang, D., Guo, H. F., & Chan, C. K. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2011.643258 · Cited by 9
“…(USEPA 1996; Wichmann et al. 2000; Sioutas et al. 2005; Guo et al. 2008; Solomon et al. 2008; Zhu et al. 2008; Buonanno et al. 2009; Hagler et al. 2009) and indoor air (Abt et al. 2000; Wallace and Howard-Reed 2002; Wallace et al. 2008; Guo et al. 2010; Zhang and Zhu 2010; Wallace and Ott 2011).”
BackgroundThe impact of control strategies on filtration performance
Li, T., & Siegel, J. A. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111378 · Cited by 9
Or, V. W., Alves, M. R., Wade, M., Schwab, S., Corsi, R. L., & Grassian, V. H. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c06260 · Cited by 9
Noble, C., Lawless, P. A., & Rodes, C. E. (2005) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.200490014 · Cited by 9
Trassierra, C. V., Cardellini, F., Buonanno, G., & Felice, P. D. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.017 · Cited by 9
Behavioral characteristics to airborne particles generated from commercial spray products
Kim, T., Park, J., Seo, J., Yoon, H., Lee, B., Lim, H., Lee, D., Kim, P., Yoon, C., Lee, K., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105747 · Cited by 9
Kim, B., Park, J., & Jeong, J. (2019) · Sustainability · doi:10.3390/su11041036 · Cited by 8
Sarnosky, K., Benden, M. E., Cizmas, L. H., Regan, A. K., & Sansom, G. (2021) · International Journal of Environmental Monitoring and Analysis · doi:10.11648/j.ijema.20210902.12 · Cited by 8
“5 were collected due to their clinical relevance [10-12] and established presence in residential spaces [13, 14].”
BackgroundAttachment rate characteristics of different wide used aerosol sources in indoor air
Mostafa, M. Y. A., Khalaf, H. N. B., & Zhukovsky, M. V. (2021) · Journal of Environmental Health Science and Engineering · doi:10.1007/s40201-021-00653-6 · Cited by 8
Monitoring and control of particulate matter in indoor air: A review
Gupta, A. K., & Bhandari, M. (2011) · Journal of Applied and Natural Science · doi:10.31018/jans.v3i1.172 · Cited by 8
Metal Exposure for Residents Near Diesel Transport Routes
Kuo, C., Wang, J., Yeh, C., Chen, M., Kuo, C.-W., Chiang, C.-Y., & Chou, H.-L. (2010) · Journal of Environmental Science and Health Part C · doi:10.1080/10590500903585374 · Cited by 7
Aerodynamic Resuspension of Particles Due to a Falling Flat Disk
Elhadidi, B., & Khalifa, H. E. (2013) · Particulate Science And Technology · doi:10.1080/02726351.2011.639047 · Cited by 7
“Recent studies identified human activities such as walking= stomping, vacuuming, and dropping of objects as major contributors to increased indoor concentrations of suspended particles (Brauer et al. 1999; Abt et al. 2000; Ferro et al. 2004a; Zhang et al. 2009).”
BackgroundImpact of Outdoor Particles on Indoor Air
Chen, C., & Zhao, B. (2021) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_9-1 · Cited by 7
A Numerical Study of the Particle Penetration Coefficient of Multibended Building Crack
Yang, Y. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.02.0058 · Cited by 7
“Using real-time indoor and outdoor particle size distribution data, Abt et al. (2000) found that 20%–43% of 2–10-µm indoor particles and 63%–92% of 0.02–0.3-µm indoor particles originate outdoors.”
InfluentialUser Influence on Indoor Aerosol Model Calibration
Hussein, T., Mølgaard, B., & Hämeri, K. J. (2011) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2010.12.0104 · Cited by 7
“…compartment; an approach that can be also found in the literature (e.g. Thatcher and Layton, 1995; Jamriska et al., 1999; Kulmala et al., 1999; Abt et al., 2000a, b; Mosley et al., 2001; Thornburg et al., 2001; Riley et al., 2002; Thatcher et al., 2002; Jamriska et al., 2003; Asmi et al.,…”
BackgroundMarín-Centeno, H., & Díaz‐Toro, E. C. (2010) · PubMed · Cited by 7
Protecting building occupants against the inhalation of outdoor-origin aerosols
Dillon, M. B., Sextro, R. G., & Delp, W. W. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118773 · Cited by 7
Anti-perspirant deodorant particulate matter temporal concentrations during home usage
Seller, V. T., Brilliant, C. D., Morgan, C., Lewis, S. P., Duckers, J. M., Boy, F., & Lewis, P. D. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107738 · Cited by 6
El-Batrawy, O. (2010) · Cited by 6
Pagel, É. C., Reis, N. C., de Alvarez, C. E., Santos, J. M., Beghi, S., Boechat, J. L., Nishikawa, M. M., Antunes, P. W. P., & Cassini, S. T. A. (2017) · Indoor and Built Environment · doi:10.1177/1420326x17719953 · Cited by 6
“For urban areas, Abt et al.(29) have shown that for low air exchange rates, 57–80% of indoor particles from 2 to 10 mm are from indoor sources, including cooking, cleaning and movement of people and only 20–43% from outdoor sources.”
BackgroundChang, L., Lee, Y., Kim, C.-K., & Lee, D. S. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.07.009 · Cited by 6
Shinohara, N., & Yoshida, H. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2021.129934 · Cited by 8
Che, W., Li, A. T. Y., & Lau, A. K. H. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-01093-9 · Cited by 6
“Factors that may possibly affect the abundance of the selected pollutants indoor were screened based on literature review, including outdoor concentration, ventilation and filtration, indoor thermal condition, air conditioning, and occupants’ activity (Abt et al. 2000; Che et al. 2021; Che et al. 2019a, 2019b; El-Shar…”
BackgroundCharacterization of decay and emission rates of ultrafine particles in indoor ice rink
Kim, J., & Lee, K. (2012) · Indoor Air · doi:10.1111/ina.12018 · Cited by 6
Air pollutant penetration through airflow leaks into buildings
Lawrence Berkeley National Lab. (LBNL), B., Liu, D.-L., & USDOE Office of Energy Efficiency and Renewable Energy (EERE) (2002) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/816065 · Cited by 6
Assessment of exposure effects of indoor particles in different microenvironments
Özlü, E. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-01071-1 · Cited by 6
Potential exposure of adults and children to particles from resuspended nano-enabled consumer sprays
He, R., McAtee, J., & Mainelis, G. (2024) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.171459 · Cited by 6
Li, K., Liu, F., Luo, Y., & Khoso, M. A. (2025) · Energies · doi:10.3390/en18092332 · Cited by 6
Zhao, Y., Zheng, W., Ma, S., Kong, W., Han, B., & Yu, J. (2023) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220357 · Cited by 5
Lai, Y., Ridley, I. A., & Brimblecombe, P. (2020) · Urban Science · doi:10.3390/urbansci5010002 · Cited by 5
Measuring Particle Concentrations and Composition in Indoor Air
Wallace, L. A., & Hopke, P. K. (2021) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_19-2 · Cited by 5
Kobayashi, R., Liu, X., Wong, P., Wu, D., Kaur, R., Chiang, T., & Kado, N. Y. (2010) · Cited by 5
Park, S., Kim, J.-H., Joe, G.-S., Yeo, M.-S., & Kim, K.-W. (2015) · 대한건축학회 논문집 - 계획계 · doi:10.5659/jaik_pd.2015.31.12.215 · Cited by 5
Sjaastad, A. K. (2010) · NORA - Norwegian Open Research Archives · Cited by 12
Evaluation of fixed and adaptive concentration thresholds for particle filter systems
Mendell, A. Y., Olson, A. W., & Siegel, J. A. (2022) · Indoor Air · doi:10.1111/ina.13134 · Cited by 4
Cerqueira, M., Marques, D. L., Caseiro, A., & Pio, C. A. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.11.043 · Cited by 4
The impacts of building opening characteristics on dust particle deposition indoors
Mohammed, M. A., Bulama, K., Bukar, A. M., Modu, M. A., Usman, A. A., Lawan, A. K., & Habib, G. A. (2023) · International Journal of Building Pathology and Adaptation · doi:10.1108/ijbpa-10-2022-0162 · Cited by 4
Thermally Modified Calcium Oxalate Phytoliths as Markers for Biomass Fire Sources
Crutcher, R., & Crutcher, H. (2020) · The Microscope · doi:10.59082/qimk8305 · Cited by 4
Evaluating Human Exposure to Fine Particulate Matter Part I: Measurements
Millar, G., Abel, T., Allen, J. M., Barn, P. K., Noullett, M., Spagnol, J., & Jackson, P. L. (2010) · Geography Compass · doi:10.1111/j.1749-8198.2010.00325.x · Cited by 6
Pagel, É. C., Reis, N. C., de Alvarez, C. E., & Santos, J. M. (2017) · Ambiente Construído · doi:10.1590/s1678-86212018000100232 · Cited by 5
“Real-time particle size distribution data is used in conjunction with time-activity data to provide information on the concentration and origin of indoor particles (ABT et al., 2000).”
MethodWallace, L. A., & Smith, K. R. (2006) · CRC Press eBooks · doi:10.1201/9781420012637.ch8 · Cited by 4
Moisture and fungal spore transport in outdoor air-ventilated crawl spaces in a cold climate
Airaksinen, M. (2003) · Aaltodoc (Aalto University) · Cited by 4
Yoshihara, J., Yamanaka, T., Kobayashi, T., Yamasawa, H., Kobayashi, N., Nagata, H., & Okamoto, S. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114360 · Cited by 3
Contextual Factors That Impact the Performance of Portable Air Cleaners: A Critical Review
Mendell, A. Y., Lee, S., & Siegel, J. A. (2026) · Environmental Science & Technology · doi:10.1021/acs.est.5c12929 · Cited by 3
Pollutions of Cooking Oil Fume and Health Risks
Li, A., & Kosonen, R. (2019) · Springer eBooks · doi:10.1007/978-981-13-6496-9_3 · Cited by 4
Vega, E., Wellens, A., Namdeo, A. K., Meza‐Figueroa, D., Ornelas, O., Entwistle, J., & Bramwell, L. (2025) · Atmosphere · doi:10.3390/atmos16091039 · Cited by 3
Reducing in-home exposure to air pollution
Singer, B. C. (2016) · Cited by 3
Measuring Particle Concentration and Compositions in Indoor Air
Wallace, L. A., & Hopke, P. K. (2021) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_19-1 · Cited by 3
Lazaridis, M., & Colbeck, I. (2010) · Environmental pollution · doi:10.1007/978-90-481-8663-1_1 · Cited by 3
Marsik, T., & Johnson, R. (2007) · Indoor and Built Environment · doi:10.1177/1420326x07084288 · Cited by 3
Kousa, A. (2002) · Työväentutkimus Vuosikirja · Cited by 3
Chen, C., Wang, W., Zhong, X., Deng, C., Lu, Y., Zhang, W., Chen, C., & Shi, F. (2026) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2026.141423 · Cited by 2
Impact of traffic densities on indoor air quality
Abdel-Aziz, R. A.-Z., & Radwan, S. M. (2019) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2019.1.3.0027 · Cited by 2
“(2000) [36] found that indoor activities especially cleaning, contributed 50% to 80% of the concentrations of indoor particles.”
BackgroundPedata, P. (2025) · Giornale italiano di medicina del lavoro ed ergonomia · doi:10.4081/gimle.463 · Cited by 2
“Short-term studies including residential indoor ultrafine particle measurements have been carried out by several investigators (25-27).”
Impact of Outdoor Particles on Indoor Air
Chen, C., & Zhao, B. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_9 · Cited by 2
Wang, S., Cohen, J. B., Wang, X., Chen, W., Deng, W., Tiwari, P., Yang, Y., & Lolli, S. (2023) · Environmental Research Communications · doi:10.1088/2515-7620/ad1422 · Cited by 2
HVAC filters as “passive ” samplers: fate analysis of indoor particles
Noris, F., Kinney, K. A., & Siegel, J. A. (2015) · Cited by 2
Indoor Air Pollutants Influenced by Haze and Their Health Impacts on Malaysian students
Elbayoumi, M. (2020) · Israa University Journal for Applied Science · doi:10.52865/mbvn8941 · Cited by 3
Wang, W., Kimoto, S., Huang, R., Matsui, Y., Yoneda, M., Wang, H., & Wang, B. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.151527 · Cited by 2
Air filtration : predicting and improving indoor air quality and energy performance
Montgomery, J. (2015) · cIRcle (University of British Columbia) · doi:10.14288/1.0166381 · Cited by 2
Indoor PM10 Upregulates Pro-inflammatory Mediators in Bronchial Epithelial CellsPreprint
Zhang, C., Asif, H., Calcagno, T., Kumar, N., Fregien, N. L., & Mirsaeidi, M. S. (2020) · Preprints.org · doi:10.20944/preprints202008.0315.v1 · Cited by 2
“Indoor PM10 may come from indoor activities like cooking, or it may be transported from outdoor air pollution [1, 2].”
BackgroundFiltration Efficiency of Intermediate Ventilation Air Filters on Ultrafine and Submicron Particles
Maroto, M. D. (2011) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 2
Um, C. Y., Preble, C. V., Zhao, H., Delp, W. W., Kirchstetter, T. W., Li, J., Schiavon, S., & Singer, B. C. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114333 · Cited by 1
Relationship between Indoor/Outdoor Concentrations of Particles: A Critical Review
He, C., & Morawska, L. (2003) · Cited by 1
A modelling tool for PM10 exposure assessment: an application example
Angelino, E., Costa, M. P., Peroni, E., & Sala, C. (2008) · WIT transactions on ecology and the environment · doi:10.2495/air080211 · Cited by 1
Frey, S. E. (2014) · PhDT · Cited by 1
Hussein, T., & Kulmala, M. (2010) · Environmental pollution · doi:10.1007/978-90-481-8663-1_8 · Cited by 1
“Thatcher et al. 2002; Long et al. 2001; Abt et al. 2000; Thatcher and Layton 1995).”
BackgroundAerosol chemistry and physics: Indoor perspective
Sextro, R. G., & Gundel, L. A. (2004) · CRC Press eBooks · doi:10.1201/9780203493182.ch10 · Cited by 1
Indoor–Outdoor Relationships of Particle Number and Mass in European Cities
Hoek, G., Hänninen, O., & Cyrys, J. (2013) · The handbook of environmental chemistry · doi:10.1007/698_2012_212 · Cited by 1
Measuring Particle Concentrations and Composition in Indoor Air
Wallace, L. A., & Hopke, P. K. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_19 · Cited by 2
Bernal, S. M. (2018) · UA Campus Repository (The University of Arizona) · Cited by 1
Evaluation of the global performance of smart ventilation in low energy housing
Poirier, B. (2023) · theses.fr (ABES) · doi:10.70675/c267634cz22c8z4b44zb0e3za4078e77ebb1 · Cited by 3
Exposure assessment and source apportionment of size fractions of airborne particulate matter
Arhami, M. (2009) · University of Southern California Digital Library · doi:10.25549/usctheses-m2085
Measuring Aerosol Particle Behaviour due to Human Activity Indoors for Re-Exposure Evaluation
McDonagh, A. (2013) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/17958
DEVELOPING METHODOLOGY FOR EXPOSURE ASSESSMENT OF AIR POLLUTANTS IN SCHOOLS
Anopa, Y. (2011) · OpenGrey (Institut de l'Information Scientifique et Technique)
Cheung, K. (. (2012) · University of Southern California Digital Library · doi:10.25549/usctheses-c3-49632
Stephens, B. R. (2012) · Texas ScholarWorks (Texas Digital Library)
Lee, W. (2015) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
A Novel, Periodic Sampling Method to Assess Airborne Bacteria Populations
Chatterjee, K. (2011) · OhioLink ETD Center (Ohio Library and Information Network)
California, I. (2004) · Cited by 5
Zwerfrook en alternatieven voor rookruimten
Opperhuizen, A., Sleijffers, A., Cremers, H., Jacobs, P., Knoll, B., Borsboom, W., & Gbo (2010) · Rivm Repository (Netherlands National Institute for Public Health and the Environment)
Mathematical modeling of particle deposition and distribution in indoor environments
Chen, F. (2006) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/5245
Ouaret, R. (2016) · theses.fr (ABES) · doi:10.70675/b2ebe192z625dz4fdfzba49z69990f2854b3 · Cited by 1
“Une analyse par régression linéaire multiple a été appliquée afin d’estimer la contribution des différentes activités domestiques : la cuisine (cuisson, griller, faire sauter etc) ; le nettoyage (aspirateur etc) ; l’occupation (caractérisée par le mouvement des occupants) et le lavage (Abt et al., 2000).”
MethodPagel, É. C. (2015) · Americanae (AECID Library) · Cited by 2
Howard-Reed, C., Wallace, L. A., & Emmerich, S. J. (2003) · doi:10.1002/https://dx.doi.org/10.6028/nist.ir.7068
“…conducted either in controlled test houses (Offermann et al., 1985; Xu et al. 1994; Thatcher et al., 2002; Emmerich and Nabinger, 2001) or in occupied or unoccupied houses (Thatcher and Layton 1995; Wallace et al., 1997; Fogh et al., 1997; Abt et al., 2000; Long et al., 2001; Vette et al., 2001).”
BackgroundMethodResultInfluentialParticulate matter inside residences of elderly in the Metropolitan Area of São Paulo
Segalin, B. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.14.2019.tde-29052018-134910
Habchi, C., Ghali, K., & Ghaddar, N. (2019) · Renewable Energy and Power Quality Journal · doi:10.24084/repqj17.244
Kang, K., Kim, H., Lee, Y. G., & Kim, T. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/609/4/042105
Impact of Residential HVAC Filters on Particle Concentration and Exposure
Zhang, Y. (2020) · TSpace (University of Toronto)
Li, H., & Yi, W. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1992/2/022002
(2003) · CRC Press eBooks · doi:10.1201/9780203911693.bmatt1
Gómez, S. I. S. (2021) · Repositorio Institucional Zaloamati (Universidad Autónoma Metropolitana) · doi:10.24275/uama.6734.8743
Análise do material particulado (indoor/outdoor) e efeitos na saúde em um Lar de idosos de São Paulo
Sousa, N. A. (2021) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.14.2021.tde-26042022-142742
Metadata
- Authors
- Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P.
- Affiliations
- Harvard University (US)
- Corresponding author
- Abt, Eileen
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-02
- Volume
- 34
- Issue
- 17
- Pages
- 3579-3587
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2068336202
- Cited by
- 411
- References
- 17
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 15 · 2021: 29 · 2020: 23 · 2019: 18 · 2018: 19 · 2017: 11 · 2016: 16 · 2015: 29 · 2014: 21 · 2013: 22 · 2012: 19
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air pollution, particulate matter, cooking emissions, indoor work, air exchange rate, penetration efficiency, particle size distribution, particle decay rates, gravitational settling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.