Relative Contribution of Outdoor and Indoor Particle Sources to Indoor Concentrations
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The effect of indoor particle sources on indoor particle size distributions and concentrations was previously investigated using real-time indoor and outdoor particle size distribution data collected in four homes in Boston in 1996. These data demonstrated the importance of indoor sources (i.e., cooking, cleaning, and movement of people) and air exchange rates on observed indoor concentrations. As part of the continued analyses of these data, a simple physical model was used to determine the source emission and infiltration rates for specific particle sizes. Decay rates were also estimated. Cooking, cleaning, and indoor work (characterized by movement of people) significantly increased PM (0.7 - 10) concentrations by 0.27, 0.27, and 0.25 μm 3 cm - 3 min - 1, respectively. Cooking was the only variable significantly associated with generation of particles less than 0.5 μm in diameter. Outdoor particles (0.02−0.5 and 0.7−10 μm) were found to contribute significantly to indoor particle levels. Effective penetration efficiencies ranged from 0.38 to 0.94 for 0.02−0.5 μm particles and from 0.12 to 0.53 for 0.7−10 μm particles. Estimates for 0.7−10 μm particles decreased with increasing particle size, reflecting the influence of deposition losses from gravitational settling. The real-time particle size distribution data in conjunction with time−activity information provides valuable information on the origin and fate of indoor particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Abt et al. [12] found that cleaning activities and the movement of people significantly increased PM (0.7-10) concentrations by 0.27 µm 3 /cm 3 and 0.25 µm 3 /cm 3 , respectively, per minute in domestic buildings in Boston.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [12]
Citations
Cites
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Özkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Atmospheric Chemistry: Fundamentals and Experimental Techniques
Ronneau, C. (1987) · Eos, Transactions American Geophysical Union · doi:10.1029/eo068i049p01643-01 · Cited by 381
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Self-citationSource apportionment of indoor aerosols in Suffolk and Onondaga counties, New York
Koutrakis, P., Briggs, S. L. K., & Leaderer, B. P. (1992) · Environmental Science & Technology · doi:10.1021/es00027a012 · Cited by 184
Self-citationA study of characterize indoor particles in three non-smoking homes
Kamens, R. M., Lee, C.-T., Wiener, R. W., & Leith, D. E. (1991) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(91)90136-u · Cited by 139
Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles
Raunemaa, T. M., Kulmala, M., Saari, H., Olin, M., & Kulmala, M. H. (1989) · Aerosol Science and Technology · doi:10.1080/02786828908959296 · Cited by 96
Modeling of Indoor Air Quality and Exposure
Nagda, N. L. (1993) · doi:10.1520/stp1205-eb · Cited by 71
The relationship between airborne acidity and ammonia in indoor environments.
Suh, H. H., Koutrakis, P., & Spengler, J. D. (1994) · PubMed · Cited by 51
Self-citation
Research works printed but not linked: 6
- Wallace, L.; Quackenboss, J.; Rhodes, C. InAWMA/EPA Symposium on the Measurement of Toxic and Related Air Pollutants; Research Triangle Park, NC, 1997; pp 860−871.
- Özkaynak H., The Particle TEAM (PTEAM) Study: Analysis of the Data−Final Report, 1994
- Özkaynak H., 1996, J. Exp. Anal. Environ. Epidemiol, 6, 57
- Brüel, 1990, Instruction Manual for the Multi-Gas Monitor Type 1302
- Suh H. H., 1994, J. Exp. Anal. Environ. Epidemiol, 4, 1
- Milford J. B., 1987, J. Air Pollut. Control Assoc, 37, 125
Cited by
Items 401–419 of 419
Seigneur, C. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108674614.012
Komae, S., Sato, K., & Sekiguchi, K. (2022) · Research Square · doi:10.21203/rs.3.rs-1668041/v1
Development of information and optimisation solutions for real-time monitoring of indoor air quality
Nguyen, T. H. (2022) · theses.fr (ABES) · doi:10.70675/351b6541z3d27z442dzba1eze873046143c9
Development of Airborne Particle Filtering System Using IoT
Mahesh, N., Mrunalini, T., Dhanush, M., Prabu, P., Janadharshini, V., & Ashok, S. (2024) · International Conference on Electronics, Communication and Aerospace Technology (ICECA) · doi:10.1109/iceca63461.2024.10800917
Yee, S., Won, Y., Cummings, B. E., Waring, M. S., Bahnfleth, W. P., & Rim, D. (2025) · Environmental Science Processes & Impacts · doi:10.1039/d5em00036j
Implementación y evaluación de políticas para el control del tabaquismo en los hospitales
Martínez, C. (2011) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) · Cited by 1
Božič, T. (2023) · Repository of the University of Ljubljana (University of Ljubljana)
Yock, Y. (2021) · eScholarship (California Digital Library)
Indoor air quality and health exposure in an educational campus in Western India
Shrivastava, A., Konwar, D., & Bhattu, D. (2026) · Atmospheric Environment · doi:10.1016/j.atmosenv.2026.121790
Particle Filtration in the Home
Mendell, A. Y. (2025) · TSpace (University of Toronto)
Integration of indoor air quality in the life cycle assessment of buildings
Bhoonah, R. (2023) · theses.fr (ABES) · doi:10.70675/fe3275d8zd009z4f21z9513zf935fade36d1
Advancing the Applications of Low-Cost Sensors for Indoor and Outdoor Air Quality Monitoring
Lekamge, S. A. (2026) · Queensland University of Technology · doi:10.5204/thesis.eprints.267132
Determination of deposition rates from indoor particle dynamics
Kulmala, I. K., Siilin, N., Hakala, J., Ehder-Gahm, I., Kultanen, M., & Säämänen, A. J. (2026) · Aerosol Science and Technology · doi:10.1080/02786826.2026.2754776
Ironing as a Source of Indoor Aerosol Particles: Effects of Ventilation and Ironing Conditions
Blanco‐Alegre, C., Vicente, E. D., Calvo, A., Oduber, F., Alves, C. A., & Fraile, R. (2026) · Atmosphere · doi:10.3390/atmos17111063
Data-dependent Performance of Machine Learning Calibration for Low-Cost Indoor Particle Sensors
Park, S., Jeong, K., Rim, D., Lee, J., & Lee, J. (2026) · Environmental Pollution · doi:10.1016/j.envpol.2026.129522
Characterisation of the chemical properties and behaviour of aerosols in the urban environment
Young, D. E. (2014) · Research Explorer (The University of Manchester)
Połednik, B., Dudzińska, M. R., & Skwarczyński, M. (2009) · Archives of Environmental Protection
Metadata
- Authors
- Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P.
- Affiliations
- Harvard University (US)
- Corresponding author
- Abt, Eileen
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-02
- Volume
- 34
- Issue
- 17
- Pages
- 3579-3587
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2068336202
- Cited by
- 411
- References
- 17
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 15 · 2021: 29 · 2020: 23 · 2019: 18 · 2018: 19 · 2017: 11 · 2016: 16 · 2015: 29 · 2014: 21 · 2013: 22 · 2012: 19
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air pollution, particulate matter, cooking emissions, indoor work, air exchange rate, penetration efficiency, particle size distribution, particle decay rates, gravitational settling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.