Relative Contribution of Outdoor and Indoor Particle Sources to Indoor Concentrations
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The effect of indoor particle sources on indoor particle size distributions and concentrations was previously investigated using real-time indoor and outdoor particle size distribution data collected in four homes in Boston in 1996. These data demonstrated the importance of indoor sources (i.e., cooking, cleaning, and movement of people) and air exchange rates on observed indoor concentrations. As part of the continued analyses of these data, a simple physical model was used to determine the source emission and infiltration rates for specific particle sizes. Decay rates were also estimated. Cooking, cleaning, and indoor work (characterized by movement of people) significantly increased PM (0.7 - 10) concentrations by 0.27, 0.27, and 0.25 μm 3 cm - 3 min - 1, respectively. Cooking was the only variable significantly associated with generation of particles less than 0.5 μm in diameter. Outdoor particles (0.02−0.5 and 0.7−10 μm) were found to contribute significantly to indoor particle levels. Effective penetration efficiencies ranged from 0.38 to 0.94 for 0.02−0.5 μm particles and from 0.12 to 0.53 for 0.7−10 μm particles. Estimates for 0.7−10 μm particles decreased with increasing particle size, reflecting the influence of deposition losses from gravitational settling. The real-time particle size distribution data in conjunction with time−activity information provides valuable information on the origin and fate of indoor particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Abt et al. [12] found that cleaning activities and the movement of people significantly increased PM (0.7-10) concentrations by 0.27 µm 3 /cm 3 and 0.25 µm 3 /cm 3 , respectively, per minute in domestic buildings in Boston.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [12]
Citations
Cites
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Özkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Atmospheric Chemistry: Fundamentals and Experimental Techniques
Ronneau, C. (1987) · Eos, Transactions American Geophysical Union · doi:10.1029/eo068i049p01643-01 · Cited by 381
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Self-citationSource apportionment of indoor aerosols in Suffolk and Onondaga counties, New York
Koutrakis, P., Briggs, S. L. K., & Leaderer, B. P. (1992) · Environmental Science & Technology · doi:10.1021/es00027a012 · Cited by 184
Self-citationA study of characterize indoor particles in three non-smoking homes
Kamens, R. M., Lee, C.-T., Wiener, R. W., & Leith, D. E. (1991) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(91)90136-u · Cited by 139
Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles
Raunemaa, T. M., Kulmala, M., Saari, H., Olin, M., & Kulmala, M. H. (1989) · Aerosol Science and Technology · doi:10.1080/02786828908959296 · Cited by 96
Modeling of Indoor Air Quality and Exposure
Nagda, N. L. (1993) · doi:10.1520/stp1205-eb · Cited by 71
The relationship between airborne acidity and ammonia in indoor environments.
Suh, H. H., Koutrakis, P., & Spengler, J. D. (1994) · PubMed · Cited by 51
Self-citation
Research works printed but not linked: 6
- Wallace, L.; Quackenboss, J.; Rhodes, C. InAWMA/EPA Symposium on the Measurement of Toxic and Related Air Pollutants; Research Triangle Park, NC, 1997; pp 860−871.
- Özkaynak H., The Particle TEAM (PTEAM) Study: Analysis of the Data−Final Report, 1994
- Özkaynak H., 1996, J. Exp. Anal. Environ. Epidemiol, 6, 57
- Brüel, 1990, Instruction Manual for the Multi-Gas Monitor Type 1302
- Suh H. H., 1994, J. Exp. Anal. Environ. Epidemiol, 4, 1
- Milford J. B., 1987, J. Air Pollut. Control Assoc, 37, 125
Cited by
Items 101–200 of 419
Liao, C., Chen, S., Chen, J.-W., & Liang, H. (2005) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2005.03.026 · Cited by 69
The influence of human physical activity and contaminated clothing type on particle resuspension
McDonagh, A., & Byrne, M. (2013) · Journal of Environmental Radioactivity · doi:10.1016/j.jenvrad.2013.10.012 · Cited by 68
“…activity, but resuspension studies focus on quantifying the level of resuspension from flooring surfaces (Ferro et al, 2004, Long et al, 2000, Abt et al, 2000); contamination on, and its removal from, clothing surfaces has received little attention, apart from a few studies in the medical…”
BackgroundSerfozo, N., Chatoutsidou, S. E., & Lazaridis, M. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.017 · Cited by 70
Indoor Residence Times of Semivolatile Organic Compounds: Model Estimation and Field Evaluation
Shin, H., McKone, T. E., Tulve, N. S., Clifton, M. S., & Bennett, D. H. (2012) · Environmental Science & Technology · doi:10.1021/es303316d · Cited by 72
Krebs, B., Burney, J. A., Zivin, J. G., & Neidell, M. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c08469 · Cited by 74
A Significant Role for Nitrate and Peroxide Groups on Indoor Secondary Organic Aerosol
Carslaw, N., Mota, T., Jenkin, M. E., Barley, M. H., & McFiggans, G. B. (2012) · Environmental Science & Technology · doi:10.1021/es301350x · Cited by 70
Cheung, K., Shafer, M. M., Schauer, J. J., & Sioutas, C. (2012) · Environmental Science & Technology · doi:10.1021/es204211v · Cited by 67
Indoor particulate matter and lung function in children
Isiugo, K., Jandarov, R., Cox, J., Ryan, P., Newman, N. C., Grinshpun, S. A., Indugula, R., Vesper, S., & Reponen, T. A. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.01.309 · Cited by 67
“(6) This estimate can be 53-73% during low indoor activity,(7) and is modified by particle penetration efficiency(8) and geographical location.”
BackgroundA study of the size distribution of aerosol particles resuspended from clothing surfaces
McDonagh, A., & Byrne, M. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2014.05.007 · Cited by 64
“Abt et al. (2000) concluded that particle emission rates significantly increased (for 0.7 – 1 µm particles) with increasing particle size during cleaning and indoor work, due to the resuspension of particles greater than 1 µm.”
InfluentialRenzetti, G., Silvestre, G., D’Amario, C., Bottini, E., Gloria‐Bottini, F., Bottini, N., Auais, A., Perez, M. K., & Piedimonte, G. (2009) · PEDIATRICS · doi:10.1542/peds.2008-1153 · Cited by 70
MacIntosh, D. L., Myatt, T. A., Ludwig, J. F., Baker, B. J., Suh, H. H., & Spengler, J. D. (2008) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.58.11.1474 · Cited by 64
Self-citationHong, B., Lin, B., & Qin, H. (2017) · Sustainable Cities and Society · doi:10.1016/j.scs.2017.07.005 · Cited by 68
Zhao, J., Birmili, W., Wehner, B., Daniels, A., Weinhold, K., Wang, L., Merkel, M., Kecorius, S., Tuch, T., Franck, U. F., et al. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2019.09.0444 · Cited by 68
“However, only relatively few studies have investigated the residential particle concentration level with a full picture of particles from 10 nm to 10 µm size range, with size-resolved information (Abt et al. , 2000; Long et al. , 2000; Diapouli, 2011; Hussein, 2017).”
Modeling indoor air pollution of outdoor origin in homes of SAPALDIA subjects in Switzerland
Meier, R., Schindler, C., Eeftens, M., Aguilera, I., Ducret-Stich, R. E., Ineichen, A., Davey, M. E., Phuleria, H. C., Probst-Hensch, N. M., Tsai, M., et al. (2015) · Environment International · doi:10.1016/j.envint.2015.05.013 · Cited by 63
“Contributions of both sources have been described previously: cooking as an important source for particles from the ultrafine to the coarse fraction (Abt et al., 2000; Baxter et al., 2007a; Beko et al., 2013; Gu et al., 2015; Kearney et al., 2011; Lai et al., 2006; Lanki et al., 2007; Wallace et al., 2003) and gas sto…”
BackgroundKopperud, R. J., Ferro, A. R., & Hildemann, L. M. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470983 · Cited by 61
Sánchez-Soberón, F., Mari, M., Kumar, V., Rovira, J., Nadal, M., & Schuhmacher, M. (2015) · Environmental Research · doi:10.1016/j.envres.2015.09.008 · Cited by 61
“…to simulate the PM levels in the indoor ME in winter and summer since amount of time that the windows are opened and the use of ventilation systems have been demonstrated to strongly influence the air exchange rates (Abt et al., 2000; Chen and Zhao, 2011; Korhonen et al., 2000; Wang et al., 2015).”
BackgroundMethodSpilak, M. P., Karottki, G. D., Kolarik, B. D., Frederiksen, M., Loft, S. H., & Gunnarsen, L. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.11.020 · Cited by 60
Managing In-home Environments through Sensing, Annotating, and Visualizing Air Quality Data
Moore, J., Goffin, P., Meyer, M., Lundrigan, P. B., Patwari, N., Sward, K. A., & Wiese, J. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3264938 · Cited by 62
Control of asthma triggers in indoor air with air cleaners: a modeling analysis
Myatt, T. A., Minegishi, T., Allen, J. G., & MacIntosh, D. L. (2008) · Environmental Health · doi:10.1186/1476-069x-7-43 · Cited by 63
“Particle deposition has been reported to be positively associated with air exchange rate due to increased turbulence of indoor air [63,64].”
Backgroundde Gennaro, G., Dambruoso, P. R., Gilio, A. D., Palma, V. D., Marzocca, A., & Tutino, M. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13010078 · Cited by 58
“Tobacco smoking, cooking, kerosene heating [15], gas burners [15,16], burning of candles [17], incense sticks [18] and biomass in open fireplaces [8,19–21] are the main indoor sources of fine and ultrafine particles [22–25].”
BackgroundKang, K., Kim, T., & Kim, H. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125852 · Cited by 60
Normal and dusty days comparison of culturable indoor airborne bacteria in Ahvaz, Iran
Soleimani, Z., Parhizgari, N., Rad, H. D., Akhoond, M. R., Kermani, M., Marzouni, M. B., Goudarzi, H., & Goudarzi, G. (2014) · Aerobiologia · doi:10.1007/s10453-014-9352-4 · Cited by 57
“It is mostly believed one of the major factors influencing indoor particulate levels is the outdoor source (Abt et al. 2000).”
BackgroundImpact of vacuum cleaning on indoor air quality
Vicente, E. D., Vicente, A., Evtyugina, M. G., Calvo, A., Oduber, F., Blanco‐Alegre, C., Castro, A., Fraile, R., Nunes, T., Lucarelli, F., et al. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107059 · Cited by 59
“The particle removal rate is the slope obtained by plotting ln(Cin/Cin0) versus time [22,51,52].”
MethodIndoor PM2.5 in Santiago, Chile, spring 2012: Source apportionment and outdoor contributions
Barraza, F., Jorquera, H., Valdivia, G. G., & Montoya, L. D. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.014 · Cited by 59
“5 concentrations of 23e67% have been estimated in previous studies (Abt et al., 2000; Meng et al., 2005a).”
BackgroundMethodResultInfluentialPerrino, C., Tofful, L., & Canepari, S. (2015) · Indoor Air · doi:10.1111/ina.12235 · Cited by 55
Hong, S., Bhardwaj, J., Han, C.-H., & Jang, J. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b03464 · Cited by 58
Tunno, B. J., Shields, K. N., Cambal, L. K., Tripathy, S., Holguín, F., Lioy, P. J., & Clougherty, J. E. (2015) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2015.06.117 · Cited by 54
“Indoor concentrations are a composite of outdoor concentrations (which vary by residential location) and indoor sources, modified by ventilation characteristics (Baxter et al., 2007a; Abt et al., 2000a).”
Wu, C., Delfino, R. J., Floro, J. N., Quintana, P. J. E., Samimi, B. S., Kleinman, M. T., Allen, R. W., & Liu, L.-J. S. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.01.061 · Cited by 53
Effect of Gas and Kerosene Space Heaters on Indoor Air Quality: A Study in Homes of Santiago, Chile
Ruiz-Rudolph, P., Toro, C., Cáceres, J., López, G., Oyola, P., & Koutrakis, P. (2010) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.60.1.98 · Cited by 57
Self-citationSegalin, B., Kumar, P., Micadei, K., Fornaro, A., & Gonçalves, F. L. T. (2016) · Atmospheric Environment · doi:10.1016/j.atmosenv.2016.10.004 · Cited by 66
“Furthermore, windows were closed during the construction inhibiting the penetration of coarse particles, but very fine particles (PM 0.25) could still infiltrate indoors through the residential shells such as cracks and fissures (Abt et al., 2000).”
InfluentialKulshreshtha, P., & Khare, M. (2011) · Atmospheric Pollution Research · doi:10.5094/apr.2011.038 · Cited by 52
Particle dose estimation from frying in residential settings
Evans, G. J., Peers, A., & Sabaliauskas, K. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00551.x · Cited by 53
Characteristics of ultrafine particle sources and deposition rates in primary school classrooms
Laiman, R., He, C., Mazaheri, M., Clifford, S., Salimi, F., Crilley, L. R., Mokhtar, M. A. M., & Morawska, L. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.05.013 · Cited by 51
“A number of studies have been published on particle emission and deposition rates, which mainly focused on residential houses (Abt et al., 2000; He et al., 2005; Long et al., 2001; Thatcher et al., 2002; Thatcher and Layton, 1995) or office buildings (Jamriska et al.”
BackgroundMethodDynamic behavior of indoor ultrafine particles (2.3‐64 nm) due to burning candles in a residence
Wallace, L. A., Jeong, S., & Rim, D. (2019) · Indoor Air · doi:10.1111/ina.12592 · Cited by 51
Indoor Particle Levels in Small- and Medium-Sized Commercial Buildings in California
Wu, X., Apte, M. G., & Bennett, D. H. (2012) · Environmental Science & Technology · doi:10.1021/es302140h · Cited by 51
Ultrafine Particles Deposition Inside Passenger Vehicles
Gong, L., Xu, B., & Zhu, Y. (2009) · Aerosol Science and Technology · doi:10.1080/02786820902791901 · Cited by 55
Montagne, D. R., Hoek, G., Nieuwenhuijsen, M. J., Lanki, T., Pennanen, A. S., Portella, M., Meliefste, K., Eeftens, M., Yli‐Tuomi, T., Cirach, M., et al. (2013) · Environmental Science & Technology · doi:10.1021/es400920a · Cited by 57
Čiužas, D., Prasauskas, T., Krugly, E., Sidaraviciute, R., Jurelionis, A., Šeduikytė, L., Kaunelienė, V., Wierzbicka, A., & Martuzevičius, D. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.07.044 · Cited by 52
Lunden, M. M., Thatcher, T. L., Hering, S. V., & Brown, N. J. (2003) · Environmental Science & Technology · doi:10.1021/es026387i · Cited by 48
Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown
Kaliszewski, M., Włodarski, M., Młyńczak, J., & Kopczyński, K. (2020) · Sensors · doi:10.3390/s20247290 · Cited by 53
Numerical study of the effects of trees on outdoor particle concentration distributions
Ji, W., & Zhao, B. (2014) · Building Simulation · doi:10.1007/s12273-014-0180-9 · Cited by 48
“2001), but outdoor particles contribute significantly to indoor particle pollution (Abt et al. 2000; Kopperud et al. 2004; Lee et al. 2001; Letz et al. 1984; Turpin et al. 2007; Chen and Zhao 2011).”
BackgroundRohra, H., Tiwari, R., Khare, P., & Taneja, A. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.03.095 · Cited by 52
Fine and Ultrafine Particle Decay Rates in Multiple Homes
Wallace, L. A., Kindzierski, W. B., Kearney, J. P., MacNeill, M., Héroux, M.-È., & Wheeler, A. J. (2013) · Environmental Science & Technology · doi:10.1021/es402580t · Cited by 48
Fungal spore transport through a building structure
Airaksinen, M., Kurnitski, J., Pasanen, P. O., & Seppänen, O. (2004) · Indoor Air · doi:10.1046/j.1600-0668.2003.00215.x · Cited by 47
“The highest deposition rates had been reported mainly from field settings (Abt et al. 2000, Long et al. 2001, Vette et al. 2001), where the control of experimental settings is limited.”
BackgroundBrandl, H., Fricker-Feer, C., Ziegler, D., Mandal, J., Stephan, R., & Lehner, A. (2013) · Journal of Dairy Science · doi:10.3168/jds.2013-7028 · Cited by 47
“Wet and dry cleaning operations often result in the formation of bioaerosols in the form of water droplets or dry dust originating from sweeping or directly from the exhaust of vacuum cleaners (Abt et al., 2000).”
BackgroundSalma, I., Dosztály, K., Borsós, T., Söveges, B., Weidinger, T., Kristóf, G., Peter, N.-K., & Kertész, Z. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.09.070 · Cited by 49
“The material flows for the halls with a HVAC facility can be expressed as (Abt et al., 2000): Fin ¼ coutpQinf þ ð1 hÞðcoutQma þ cinQretÞ; (2) Fout ¼ cinQexf þ cinQexh þ cinQret; (3) where cout is the concentration in the outdoor air, p is the penetration factor, Qma, Qret, Qexh, Qinf and Qexf are…”
BackgroundNa, K., & COCKERIII, D. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.01.054 · Cited by 47
“According to a study by Abt et al. (2000) on contribution of outdoor and indoor particle sources to indoor concentrations, effective penetration efficiencies for 0.02–0.5mm particles was higher than 0.7–10mm by a factor of two.”
BackgroundInfluentialRojas‐Bracho, L., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470897 · Cited by 47
Self-citationChen, R., Zhou, B., Kan, H., & Zhao, B. (2013) · Environmental Pollution · doi:10.1016/j.envpol.2013.07.024 · Cited by 47
Human-Induced Particle Re-Suspension in a Room
Oberoi, R. C., Choi, J., Edwards, J. R., Rosati, J. A., Thornburg, J. W., & Rodes, C. E. (2010) · Aerosol Science and Technology · doi:10.1080/02786820903530852 · Cited by 46
Polidori, A., Cheung, K., Arhami, M., Delfino, R. J., Schauer, J. J., & Sioutas, C. (2009) · Atmospheric chemistry and physics · doi:10.5194/acp-9-4521-2009 · Cited by 46
“Because one of the aims of this study is to evaluate the effects of outdoor air pollutants on indoor exposure, we estimated air exchange rates (AER) from CO measurements during periods affected by a dominant indoor source (Abt et al., 2000) and determined infiltration factors ( Finf), which are key determinants of the…”
BackgroundFluorine mass balance analysis and per- and polyfluoroalkyl substances in the atmosphere
Lin, H., Taniyasu, S., Yamazaki, E., Wu, R., Lam, P. K. S., Eun, H., & Yamashita, N. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129025 · Cited by 47
Co-optimisation of indoor environmental quality and energy consumption within urban office buildings
Quang, T. N., He, C., Knibbs, L. D., de Dear, R., & Morawska, L. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.09.021 · Cited by 55
Indoor air quality in 24 California residences designed as high-performance homes
Less, B. D., Mullen, N. A., Singer, B. C., & Walker, I. S. (2015) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.961850 · Cited by 45
“Another limitation was that particles were not measured outside, even though outside concentrations are known to impact those indoors (Abt et al. 2000b; Weisel et al. 2005).”
BackgroundHappo, M. S., Sippula, O., Jalava, P., Rintala, H., Leskinen, A., Komppula, M., Kuuspalo, K., Mikkonen, S. J., Lehtinen, K. E. J., Jokiniemi, J. K., et al. (2014) · Particle and Fibre Toxicology · doi:10.1186/s12989-014-0060-6 · Cited by 50
“5 μm<Dp <10 μm) are filtrated or they rapidly deposit on surfaces during the house air intake [14,17].”
BackgroundLazaridis, M., Aleksandropoulou, V., Hanssen, J. E., Dye, C., Eleftheriadis, K., & Katsivela, E. (2008) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.58.3.346 · Cited by 44
Hong, B., Qin, H., & Lin, B. (2018) · Atmosphere · doi:10.3390/atmos9020039 · Cited by 45
To breathe or not to breathe: Inhalational exposure to heavy metals and related health risk
Khoshakhlagh, A. H., Ghobakhloo, S., Peijnenburg, W. J. G. M., Gruszecka‐Kosowska, A., & Cicchella, D. (2024) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.172556 · Cited by 45
Tran, D.-T., Alleman, L., Coddeville, P., & Galloo, J.-C. (2015) · Indoor and Built Environment · doi:10.1177/1420326x15610798 · Cited by 43
“and Abt et al..(57) For instance, in this work the deposition loss rate coefficient for the particles of 3.”
BackgroundAerosols generated by hardcopy devices and other electrical appliances
Salthammer, T., Schripp, T., Uhde, E., & Wensing, M. (2012) · Environmental Pollution · doi:10.1016/j.envpol.2012.01.028 · Cited by 43
“The indoor/ outdoor (I/O) ratio of particle concentrations as a function of their size and chemical composition forms the subject of various studies (Abt et al., 2000; Götschi et al., 2002; Kuhn et al., 2005; Lunden et al., 2003; Monn, 2001; Poupard et al., 2005; Riley et al., 2002).”
BackgroundSanderson, E. G., & Farant, J.-P. (2004) · Environmental Science & Technology · doi:10.1021/es030715c · Cited by 43
Residents' particle exposures in six different communities in Taiwan
Lung, S. C., Mao, I., & LIU, L. (2007) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2007.01.092 · Cited by 42
Or, V. W., Alves, M. R., Wade, M., Schwab, S., Corsi, R. L., & Grassian, V. H. (2018) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.8b00355 · Cited by 44
Identification of tobacco smoke components in indoor breathable particles by SEM–EDS
Slezáková, K., Pires, J. C. M., Martins, F. G., Pereira, M. D. C., & Alvim-Ferraz, M. C. M. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.11.019 · Cited by 41
Indoor and outdoor measurements of particle number concentration in near-highway homes
Fuller, C. H., Brugge, D., Williams, P. L., Mittleman, M. A., Lane, K., Durant, J. L., & Spengler, J. D. (2013) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2012.116 · Cited by 40
Elbayoumi, M., Ramli, N. A., & Yusof, N. F. F. M. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.036 · Cited by 42
Financial implications of modifications to building filtration systems
Montgomery, J. F., Reynolds, C. C. O., Rogak, S. N., & Green, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.11.005 · Cited by 42
Infiltration of Ambient PM2.5 through Building Envelope in Apartment Housing Units in Korea
Choi, D. H., & Kang, D. H. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.06.0287 · Cited by 40
“…the infiltration process through building leakage, three parameters have been used widely, i.e., the indoor/outdoor (I/O) ratio (Monn et al. , 1995; Abt et al. , 2000; Long and Sarnat, 2004; Lunden et al. , 2008), the infiltration factor (Lee et al. , 1997; Landis et al. , 2001; Wallace and…”
Investigation of PM2.5 and carbon dioxide levels in urban homes
Abdel-Salam, M. M. M. (2015) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2015.1040138 · Cited by 44
“5 can largely contribute to indoor PM concentrations when air exchange rates are high (Abt et al., 2000; Meng et al., 2005).”
BackgroundExposure to ultrafine particles in relation to indoor events and dwelling characteristics
Spilak, M. P., Frederiksen, M., Kolarik, B. D., & Gunnarsen, L. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.01.007 · Cited by 44
Multi-zone simulation of outdoor particle penetration and transport in a multi-story building
Lee, B. H., Yee, S.-W., Kang, D. H., Yeo, M.-S., & Kim, K. W. (2016) · Building Simulation · doi:10.1007/s12273-016-0340-1 · Cited by 40
“(Alzona et al. 1979; Ligocki et al. 1993; Ozlaynnak et al. 1996; Abt et al. 2000; Lee and Chang 2000; Long et al. 2001; Liu et al. 2003; Wallace et al. 2003; Cao et al. 2005; Kuo and Shen 2010; Chatoutsidou et al. 2015).”
BackgroundChen, X., Jahn, H. J., Engling, G., Ward, T. J., Kraemer, A., Ho, K., Yim, S. H. L., & Chan, C. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.08.062 · Cited by 38
Eom, Y. S., Kang, D. H., Rim, D., & Yeo, M.-S. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.109986 · Cited by 39
Chatoutsidou, S. E., Mašková, L., Ondráčková, L., Ondráček, J., Lazaridis, M., & Smolík, J. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.029 · Cited by 41
“The above findings are in agreement with other studies [13,14,34,35,39,40,44,50,51] where deposition was found to depend considerably on particle size.”
MethodResultNoh, K.-C., & Hwang, J. (2010) · Indoor and Built Environment · doi:10.1177/1420326x10373213 · Cited by 37
Characteristics and control strategies of indoor particles: An updated review
Li, J., Fan, G., Ou, Y., & Deng, Q. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113232 · Cited by 37
Bari, M. A., MacNeill, M., Kindzierski, W. B., Wallace, L. A., Héroux, M.-È., & Wheeler, A. J. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.04.025 · Cited by 38
Pollutants emission scenarios for residential ventilation performance assessment. A review
Poirier, B., Guyot, G., Geoffroy, H., Woloszyn, M., Ondarts, M., & Gonze, E. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102488 · Cited by 40
Custódio, Ð., de Pinho, I. G., Cerqueira, M., Nunes, T., & Pio, C. A. (2013) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2013.12.009 · Cited by 39
Penetration of fine particles through rough cracks
Lai, A. C. K., Fung, J. L. S., Li, M., & Leung, K. Y. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.06.053 · Cited by 36
Lazaridis, M., Aleksandropoulou, V., Smolík, J., Hansen, J., Glytsos, T., Kalogerakis, N. E., & Dahlin, E. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00425.x · Cited by 36
Fazli, T., & Stephens, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.047 · Cited by 35
“…removal efficiency for MERV 6 filters of 8% and 8%, respectively, which we estimated by matching size-resolved removal efficiency data for MERV 6 filters reported in Hecker and Hofacre (2008) [123] to typical indoor particle size distributions reported by Abt et al. (2000) [119] (SI Appendix D).”
MethodInfluentialStudy on particle penetration through straight, L, Z and wedge-shaped cracks in buildings
Li, A., Ren, T., Yang, C., Lv, W., & Zhang, F. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.12.024 · Cited by 35
Xia, T., & Chen, C. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.10.046 · Cited by 35
Alshitawi, M. S., & Awbi, H. (2011) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.583708 · Cited by 36
“It is also noted that the penetration factor is generally higher for fine particles than for coarse ones (Abt et al. 2000).”
BackgroundAllen, R. W., Wallace, L. A., Larson, T. V., Sheppard, L. A., & Liu, L.-J. S. (2006) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500539 · Cited by 35
“Much recent research has focused on quantifying the PM infiltration efficiency (Finf) and the building characteristics and human behaviors that govern Finf (Abt et al., 2000; Wilson et al., 2000; Long et al., 2001; Allen et al., 2003; Williams et al., 2003; Wallace et al., 2006; Wu et al., 2006).”
BackgroundIndoor Aerosol Particle Deposition in an Empty Office
Smolík, J., Lazaridis, M., Moravec, P., Schwarz, J., Zaripov, S. K., & Ždímal, V. (2005) · Water Air & Soil Pollution · doi:10.1007/s11270-005-7146-6 · Cited by 35
Li, B., Zhu, C., Yao, R., Wang, H., Yu, W., Bu, Z., Xiong, J., Zhang, T., Essah, E., Luo, Z., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.10.045 · Cited by 34
Estimating hourly average indoor PM2.5 using the random forest approach in two megacities, China
Xu, C., Xu, D., Liu, Z., Li, Y., Li, N., Chartier, R., Chang, J., Wang, Q., Wu, Y., & Li, N. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107025 · Cited by 34
Boedicker, E. K., Emerson, E., McMeeking, G. R., Patel, S., Vance, M. E., & Farmer, D. K. (2021) · Environmental Science Processes & Impacts · doi:10.1039/d1em00087j · Cited by 34
Particle Levitation Due to a Uniformly Descending Flat Object
Khalifa, H. E., & Elhadidi, B. (2007) · Aerosol Science and Technology · doi:10.1080/02786820601064857 · Cited by 34
“Several other studies (e.g., Abt et al. 2000; Nazaroff 2004) also indicate that there is a significant increase in PM concentration in the 5–10 μm size range after human walking.”
BackgroundParticulate matter analysis at elementary schools in Curitiba, Brazil
Avigo, D., Godoi, A. F. L., Janissek, P. R., Makarovska, Y., Krata, A., Potgieter-Vermaak, S. S., Alföldy, B., Grieken, R. V., & Godoi, R. H. M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2031-y · Cited by 39
Fernández, E., Fu, M., Martínez, C., Martínez-Sánchez, J. M., López, M. J., Martín‐Pujol, A., Centrich, F., Muñoz, G., Nebot, M., & Saltó, E. (2008) · Preventive Medicine · doi:10.1016/j.ypmed.2008.09.003 · Cited by 34
Zheng, H., Deng, W., Cheng, Y., & Guo, W. F. (2016) · Environmental Geochemistry and Health · doi:10.1007/s10653-016-9844-y · Cited by 33
Zhang, Z., Gao, Y., Yuan, Q., Tan, Y., Li, H., Cui, L., Huang, Y. H., Cheng, Y., Xiu, G., Lai, S., et al. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.139684 · Cited by 34
Stephens, B. (2015) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.961849 · Cited by 33
“2004), exfiltration by air exchange (Abt et al. 2000) or dedicated exhaust fans (Singer et al.”
BackgroundArhami, M., Polidori, A., Delfino, R. J., Tjoa, T. T., & Sioutas, C. (2009) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.59.4.392 · Cited by 33
Suspension and resuspension of dry soil indoors following track-in on footwear
Hunt, A. G., & Johnson, D. L. (2011) · Environmental Geochemistry and Health · doi:10.1007/s10653-011-9400-8 · Cited by 33
“Abt et al. (2000) modeled source emissions, infiltration rates, and associated decay rates to define the subsequent distribution of particles indoors.”
BackgroundRim, D., & Novoselac, A. (2008) · Cited by 33
Levels and indoor–outdoor relationships of PM10 and soluble inorganic ions in Beirut, Lebanon
Saliba, N. A., Atallah, M., & Al-Kadamany, G. (2008) · Atmospheric Research · doi:10.1016/j.atmosres.2008.09.010 · Cited by 36
Metadata
- Authors
- Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P.
- Affiliations
- Harvard University (US)
- Corresponding author
- Abt, Eileen
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-02
- Volume
- 34
- Issue
- 17
- Pages
- 3579-3587
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2068336202
- Cited by
- 411
- References
- 17
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 15 · 2021: 29 · 2020: 23 · 2019: 18 · 2018: 19 · 2017: 11 · 2016: 16 · 2015: 29 · 2014: 21 · 2013: 22 · 2012: 19
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air pollution, particulate matter, cooking emissions, indoor work, air exchange rate, penetration efficiency, particle size distribution, particle decay rates, gravitational settling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.