Relative Contribution of Outdoor and Indoor Particle Sources to Indoor Concentrations
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The effect of indoor particle sources on indoor particle size distributions and concentrations was previously investigated using real-time indoor and outdoor particle size distribution data collected in four homes in Boston in 1996. These data demonstrated the importance of indoor sources (i.e., cooking, cleaning, and movement of people) and air exchange rates on observed indoor concentrations. As part of the continued analyses of these data, a simple physical model was used to determine the source emission and infiltration rates for specific particle sizes. Decay rates were also estimated. Cooking, cleaning, and indoor work (characterized by movement of people) significantly increased PM (0.7 - 10) concentrations by 0.27, 0.27, and 0.25 μm 3 cm - 3 min - 1, respectively. Cooking was the only variable significantly associated with generation of particles less than 0.5 μm in diameter. Outdoor particles (0.02−0.5 and 0.7−10 μm) were found to contribute significantly to indoor particle levels. Effective penetration efficiencies ranged from 0.38 to 0.94 for 0.02−0.5 μm particles and from 0.12 to 0.53 for 0.7−10 μm particles. Estimates for 0.7−10 μm particles decreased with increasing particle size, reflecting the influence of deposition losses from gravitational settling. The real-time particle size distribution data in conjunction with time−activity information provides valuable information on the origin and fate of indoor particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Abt et al. [12] found that cleaning activities and the movement of people significantly increased PM (0.7-10) concentrations by 0.27 µm 3 /cm 3 and 0.25 µm 3 /cm 3 , respectively, per minute in domestic buildings in Boston.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [12]
Citations
Cites
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Özkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Atmospheric Chemistry: Fundamentals and Experimental Techniques
Ronneau, C. (1987) · Eos, Transactions American Geophysical Union · doi:10.1029/eo068i049p01643-01 · Cited by 381
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Self-citationSource apportionment of indoor aerosols in Suffolk and Onondaga counties, New York
Koutrakis, P., Briggs, S. L. K., & Leaderer, B. P. (1992) · Environmental Science & Technology · doi:10.1021/es00027a012 · Cited by 184
Self-citationA study of characterize indoor particles in three non-smoking homes
Kamens, R. M., Lee, C.-T., Wiener, R. W., & Leith, D. E. (1991) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(91)90136-u · Cited by 139
Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles
Raunemaa, T. M., Kulmala, M., Saari, H., Olin, M., & Kulmala, M. H. (1989) · Aerosol Science and Technology · doi:10.1080/02786828908959296 · Cited by 96
Modeling of Indoor Air Quality and Exposure
Nagda, N. L. (1993) · doi:10.1520/stp1205-eb · Cited by 71
The relationship between airborne acidity and ammonia in indoor environments.
Suh, H. H., Koutrakis, P., & Spengler, J. D. (1994) · PubMed · Cited by 51
Self-citation
Research works printed but not linked: 6
- Wallace, L.; Quackenboss, J.; Rhodes, C. InAWMA/EPA Symposium on the Measurement of Toxic and Related Air Pollutants; Research Triangle Park, NC, 1997; pp 860−871.
- Özkaynak H., The Particle TEAM (PTEAM) Study: Analysis of the Data−Final Report, 1994
- Özkaynak H., 1996, J. Exp. Anal. Environ. Epidemiol, 6, 57
- Brüel, 1990, Instruction Manual for the Multi-Gas Monitor Type 1302
- Suh H. H., 1994, J. Exp. Anal. Environ. Epidemiol, 4, 1
- Milford J. B., 1987, J. Air Pollut. Control Assoc, 37, 125
Cited by
The Impact of Pollution on Worker Productivity
Zivin, J. G., & Neidell, M. (2012) · American Economic Review · doi:10.1257/aer.102.7.3652 · Cited by 1,067
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Respiratory risks from household air pollution in low and middle income countries
Gordon, S. B., Bruce, N. G., Grigg, J., Hibberd, P. L., Kurmi, O. P., Lam, K.-B. H., Mortimer, K., Asante, K. P., Balakrishnan, K., Balmes, J., et al. (2014) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(14)70168-7 · Cited by 953
Changes in indoor pollutants since the 1950s
Weschler, C. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.044 · Cited by 669
“There are multiple sources of indoor airborne particles (Abt et al., 2000), including outdoor air, indoor combustion (especially smoking and cooking), abrasion, vacuuming, re-suspension, laser printers (He et al., 2007) and ozoneinitiated chemistry (see Section 3.1).”
BackgroundInfluentialContribution from indoor sources to particle number and mass concentrations in residential houses
HE, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.027 · Cited by 585
“3 μm in diameter (Helsper et al., 1993), and were thus not measured by Lioy et. al. (1999), while they were measured in this study.”
MethodOutdoor-indoor air pollution in urban environment: challenges and opportunity
Leung, D. Y. C. (2015) · Frontiers in Environmental Science · doi:10.3389/fenvs.2014.00069 · Cited by 401
“…and outdoor environment under different measuring and ventilation conditions (Dockery and Spengler, 1981; Baek et al., 1997; Monn et al., 1997; Abt et al., 2000; Koponen et al., 2001; Adgate et al., 2002; Chan, 2002; Cyrys et al., 2004; Cao et al., 2005; Meng et al., 2007; Diapouli et al.,…”
BackgroundEffects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416
Particle emission factors during cooking activities
Buonanno, G., Morawska, L., & Stabile, L. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.03.044 · Cited by 401
“…cooking, several studies have attempted to measure the particle number concentration and size distribution of particles generated during cooking (Abt et al., 2000a, b; Brauer et al., 2000, Dennekamp et al., 2001; Hussein et al., 2006; Li et al., 1993; See and Balasubramanian, 2006a, b; He et…”
BackgroundMorawska, L., Ayoko, G. A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Clifford, S., Fu, S. C., Hänninen, O., He, C., Isaxon, C., et al. (2017) · Environment International · doi:10.1016/j.envint.2017.07.025 · Cited by 374
“5 due to different type of cooking were reported to range between 2 and 100 times more than background (pre-activity level) or outdoor concentrations (Abt et al., 2000b; He et al., 2004; Morawska et al., 2003a; Wallace et al., 2004; Wierzbicka et al., 2015).”
BackgroundAfshari, A., Matson, U., & Ekberg, L. E. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00332.x · Cited by 316
Walking-induced particle resuspension in indoor environments
Qian, J., Peccia, J., & Ferro, A. R. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.02.035 · Cited by 305
Particle deposition indoors: a review
Lai, A. C. K. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01159.x · Cited by 226
Source Strengths of Ultrafine and Fine Particles Due to Cooking with a Gas Stove
Wallace, L. A., Emmerich, S. J., & Howard-Reed, C. (2004) · Environmental Science & Technology · doi:10.1021/es0306260 · Cited by 290
Personal Exposure to Ultrafine Particles and Oxidative DNA Damage
Vinzents, P. S., Møller, P., Sørensen, M., Knudsen, L. E., Hertel, O., Jensen, F. P., Schibye, B., & Loft, S. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7562 · Cited by 288
“Major indoor sources of UFPs include smoking, cooking, candle burning, and other combustion-related processes as well as chemical reactions between, for example, terpenes and ozone (Abt et al. 2000; Dennekamp et al. 2001; Levy et al. 2000; Long et al. 2000; Ozkaynak et al. 1996).”
BackgroundParticle size characterization and emission rates during indoor activities in a house
Hussein, T., Glytsos, T., Ondráček, J., Dohányosová, P., Ždímal, V., Hämeri, K., Lazaridis, M., Smolík, J., & Kulmala, M. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.03.053 · Cited by 271
Meng, Q. Y., Turpin, B. J., Korn, L., Weisel, C. P., Morandi, M., Colome, S., Zhang, J., Stock, T., Spektor, D., Winer, A., et al. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500378 · Cited by 266
“In scenario ‘‘C’’, P (1.0) and k (0.5 h 1) are composites from other studies (Thatcher and Layton, 1995; Abt et al., 2000b; Long et al., 2001; Thornburg et al., 2001; Vette et al., 2001).”
BackgroundMethodInfluentialImpact of the 2002 Canadian Forest Fires on Particulate Matter Air Quality in Baltimore City
Sapkota, A., Symons, J. M., Kleissl, J., Wang, L., Parlange, M. B., Ondov, J., Breysse, P. N., Diette, G. B., Eggleston, P. A., & Buckley, T. J. (2005) · Environmental Science & Technology · doi:10.1021/es035311z · Cited by 249
Performance and costs of particle air filtration technologies: Air filtration technology
Fisk, W. J., Faulkner, D., Palonen, J., & Seppanen, O. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01136.x · Cited by 242
“A few supplementary calculations were performed with the alternate deposition coefficient curve shown in Figure 2, which fits the data of Abt et al. (2000) and Fogh et al. (1997).”
MethodInfluentialLinking exposure to environmental pollutants with biological effects
Sørensen, M., Autrup, H., Møller, P., Hertel, O., Jensen, S. S., Vinzents, P., Knudsen, L. E., & Loft, S. (2003) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2003.06.010 · Cited by 237
Personal exposure to ultrafine particles
Wallace, L., & Ott, W. (2011) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2009.59 · Cited by 241
“Residential indoor concentrations have also been reported (Abt et al., 2000; Dennekamp et al., 2001; Long et al., 2001; Wallace and Howard-Reed, 2002; Klepeis et al., 2003; He et al., 2004; Wallace, 2000, 2005, 2006; Wallace et al., 2004, 2008; Hoek et al., 2008).”
BackgroundOverview of HOMEChem: House Observations of Microbial and Environmental Chemistry
Farmer, D. K., Vance, M. E., Abbatt, J. P. D., Abeleira, A., Alves, M. R., Arata, C., Boedicker, E., Bourne, S., Cardoso-Saldaña, F., Corsi, R., et al. (2019) · Environmental Science: Processes & Impacts · doi:10.1039/c9em00228f · Cited by 220
A population exposure model for particulate matter: case study results for PM2.5 in Philadelphia, PA
BURKE, J. M., ZUFALL, M. J., & ÖZKAYNAK, H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500188 · Cited by 223
Development and evaluation of a personal cascade impactor sampler (PCIS)
Misra, C., Singh, M., Shen, S., Sioutas, C., & Hall, P. M. (2002) · Journal of Aerosol Science · doi:10.1016/s0021-8502(02)00055-1 · Cited by 216
Particle deposition rates in residential houses
He, C., Morawska, L., & Gilbert, D. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.03.016 · Cited by 189
“This assumption simplifies Equation 3, however, it should be noted that a number of studies have indicated that the penetration efficiency is less then one and is a function of particle size (Abt et al., 2000; Long et al., 2001).”
BackgroundMethodResultInfluentialExposure to Ambient and Nonambient Components of Particulate Matter: A Comparison of Health Effects
Ebelt, S. T., Wilson, W. E., & Brauer, M. (2005) · Epidemiology · doi:10.1097/01.ede.0000158918.57071.3e · Cited by 196
Hänninen, O. O., Lebret, E., Ilacqua, V., Katsouyanni, K., Künzli, N., Srám, R. J., & Jantunen, M. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.07.015 · Cited by 186
Wallace, L. (2006) · Aerosol Science and Technology · doi:10.1080/02786820600612250 · Cited by 187
“Indoor sources have been identified as gas stoves ( Abt et al. 2000 ; He et al.”
BackgroundEstimating the concentration of indoor particles of outdoor origin: A review
Diapouli, E., Chaloulakou, A., & Koutrakis, P. (2013) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2013.791649 · Cited by 173
“(a) and (b) Infiltration factor as a function of particle size (Abt et al., 2000). Diapouli et al. / Journal of the Air & Waste Management Association 63 (2013) 1113–1129 1115”
BackgroundMethodInfluentialSelf-citationWichmann, J., Lind, T., Nilsson, M. A.-M., & Bellander, T. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.08.023 · Cited by 182
Indoor–outdoor relationships of particle number and mass in four European cities
Hoek, G., Kos, G., Harrison, R., de Hartog, J., Meliefste, K., ten Brink, H., Katsouyanni, K., Karakatsani, A., Lianou, M., & Kotronarou, A. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.09.026 · Cited by 180
“Several studies in the USA that measured particle size distributions have also found lower infiltration factors for particles in the ultrafine range [17, 18, 20, 21].”
BackgroundInfiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness
Barn, P., Larson, T., Noullett, M., Kennedy, S., Copes, R., & Brauer, M. (2008) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500640 · Cited by 166
“Further, due to the typically short duration of forest fire events, a shorter sampling time of 48–60 h was used to estimate infiltration compared to other studies of infiltration in which sampling times ranged from 24 h to 12-month periods (Abt et al., 2000; Long et al., 2001; Wallace et al., 2005).”
MethodSinger, B. C., Pass, R. Z., Delp, W. W., Lorenzetti, D. M., & Maddalena, R. L. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.021 · Cited by 162
Bhangar, S., Mullen, N. A., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00689.x · Cited by 158
Howard-Reed, C. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.012 · Cited by 157
“, 2002; Emmerich and Nabinger, 2001) or in occupied or unoccupied houses (Thatcher and Layton, 1995; Wallace et al., 1997; Fogh et al., 1997; Abt et al., 2000; Long et al., 2001; Vette et al., 2001).”
BackgroundInfluentialCyrys, J., Pitz, M., Bischof, W., Wichmann, H. ‐., & Heinrich, J. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500317 · Cited by 149
“This model is based on the indoor air mass balance equation that has been applied in previous exposure and indoor studies (Özkaynak et al., 1996; Abt et al., 2000a).”
BackgroundMethodThatcher, T. L., Lunden, M. M., Revzan, K. L., Sextro, R. G., & Brown, N. J. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300940 · Cited by 147
“Abt et al. (2000) calculated a factor they termed the ‘effective penetration efficiency’, which combines both deposition and penetration losses for outdoor particles.”
BackgroundInfluentialWallace, L. A., & Williams, R. W. (2005) · Environmental Science & Technology · doi:10.1021/es049547u · Cited by 142
Geller, M. D., Chang, M.-C., Sioutas, C., Ostro, B. D., & Lipsett, M. J. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00340-5 · Cited by 147
Deposition rates on smooth surfaces and coagulation of aerosol particles inside a test chamber
Hussein, T., Hruška, A., Dohányosová, P., Džumbová, L., Hemerka, J., Kulmala, M., & Smolík, J. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.10.059 · Cited by 136
Rivas, I., Viana, M., Moreno, T., Bouso, L., Pandolfi, M., Alvarez-Pedrerol, M., Forns, J., Alástuey, A., Sunyer, J., & Querol, X. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.01.055 · Cited by 145
“The I/O ratio is an extensively used value of the relationship between indoor and outdoor PM concentrations (Abt et al., 2000; Arhami et al., 2010; among many others).”
BackgroundThe Impact of Pollution on Worker Productivity
Zivin, J. G., & Neidell, M. (2011) · National Bureau of Economic Research · doi:10.3386/w17004 · Cited by 154
Levy, J. I., Dumyahn, T. S., & Spengler, J. D. (2002) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500203 · Cited by 134
Chen, C., Zhao, B., Zhou, W., Jiang, X., & Tan, Z. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.07.004 · Cited by 128
Stephens, B., & Siegel, J. A. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00779.x · Cited by 127
Indoor and outdoor particle size characterization at a family house in Espoo–Finland
Hussein, T., Hämeri, K. J., Heikkinen, M. S. A., & Kulmala, M. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.03.011 · Cited by 127
Wallace, L. A. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.10.003 · Cited by 127
“…test houses (Offermann et al., 1985; Xu et al., 1994; Emmerich and Nabinger, 2001; Thatcher et al., 2002) or in occupied or unoccupied houses (Thatcher and Layton, 1995; Wallace et al., 1997; Fogh et al., 1997; Abt et al., 2000; Long et al., 2001a; Vette et al., 2001; Howard-Reed et al., 2003).”
BackgroundGas/particle distribution of polycyclic aromatic hydrocarbons in coupled outdoor/indoor atmospheres
Naumova, Y. Y., Offenberg, J. H., Eisenreich, S. J., Meng, Q., Polidori, A., Turpin, B. J., Weisel, C. P., Morandi, M. T., Colome, S. D., Stock, T. H., et al. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00820-8 · Cited by 126
Lim, J.-M., Jeong, J.-H., Lee, J.-H., Moon, J. H., Chung, Y. S., & Kim, K. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00691.x · Cited by 125
Physical Characteristics of Ultrafine Particles Emitted from Different Gas Cooking Methods
See, S. W., & Balasubramanian, R. (2006) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2006.03.0007 · Cited by 125
“…of the relationship between particulate air pollution and gas cooking, several studies have attempted to measure the concentration and size distribution of particles associated with gas cooking (Abt et al., 2000a; Abt et al., 2000b; Dennekamp et al., 2001; Li et al., 1993; Wallace et al., 2004).”
BackgroundResuspension of Particulate Matter from Carpet Due to Human Activity
Rosati, J. A., Thornburg, J. W., & Rodes, C. E. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802187069 · Cited by 122
“Previous studies have developed resuspension rates by particle size and activity from horizontal surfaces using various methods ( Thatcher and Layton 1995 ; Abt et al.”
BackgroundMethodValente, P., Forastiere, F., Bacosi, A., Cattani, G., Carlo, S. D., Ferri, M., Figà-Talamanca, I., Marconi, A., Paoletti, L., Perucci, C. A., et al. (2007) · Tobacco Control · doi:10.1136/tc.2006.019646 · Cited by 121
“Bars 46.8 30.2 to 63.5 39.6 28.0 to 56 Pre-law ( 14 )”
InfluentialInfluence of ventilation and filtration on indoor particle concentrations in urban office buildings
Quang, T. N., He, C., Morawska, L., & Knibbs, L. D. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.06.009 · Cited by 119
“Indoor activities, such as movement of building occupants, can 25 also affect and increase indoor particle levels (Abt et al., 2000a; Long et al., 2000).”
BackgroundResultWallace, L. A., Williams, R. W., Rea, A. W., & Croghan, C. W. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.08.042 · Cited by 113
Characterization of particles emitted by incense burning in an experimental house
Ji, X., Bihan, O. L., Ramalho, O., Mandin, C., D’Anna, B., Martinon, L., Nicolas, M., Bard, D., & Pairon, J. ‐. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00634.x · Cited by 112
“…contribution of indoor sources of fine and ultrafine particles but the spatial and temporal changes of the indoor levels of particles of different sizes in various rooms of the house have been described to a lesser extent (Abt et al., 2000; Ogulei et al., 2006; Wallace, 2006; Wallace et al., 2008).”
BackgroundPeng, Z., Deng, W., & Tenorio, R. (2017) · Sustainability · doi:10.3390/su9071180 · Cited by 109
“[12] found that cleaning activities and the movement of people significantly increased PM(0.”
BackgroundHan, Y., Qi, M., Chen, Y., Shen, H., Liu, J., Huang, Y., Chen, H., Liu, W., Wang, X., Liu, J., et al. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.04.026 · Cited by 109
Determining the infiltration of outdoor particles in the indoor environment using a dynamic model
Bennett, D. H., & Koutrakis, P. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2005.05.020 · Cited by 108
Self-citationFactors influencing variability in the infiltration of PM2.5 mass and its components
MacNeill, M., Wallace, L. A., Kearney, J. P., Allen, R. W., Ryswyk, K. V., Judek, S., Xu, X., & Wheeler, A. J. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.07.005 · Cited by 106
MacNeill, M., Kearney, J. P., Wallace, L. A., Gibson, M., Héroux, M. E., Kuchta, J., Guernsey, J., & Wheeler, A. J. (2013) · Indoor Air · doi:10.1111/ina.12084 · Cited by 106
Estimating Mortality Derived from Indoor Exposure to Particles of Outdoor Origin
Ji, W., & Zhao, B. (2015) · PLoS ONE · doi:10.1371/journal.pone.0124238 · Cited by 110
Wallace, L. A., & Howard-Reed, C. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470823 · Cited by 105
Volatility Characterization of Cooking-Generated Aerosol Particles
Buonanno, G., Johnson, G. R., Morawska, L., & Stabile, L. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.580797 · Cited by 104
“2000a , 2000b ; See and Balasubramanian 2006a , 2006b; Wallace et al.”
BackgroundChithra, V. S., & Nagendra, S. M. S. (2018) · Asian Journal of Atmospheric Environment · doi:10.5572/ajae.2018.12.2.87 · Cited by 107
“Furthermore, the relative impact of indoor and outdoor emissions on exposures has not been addressed in a systematic and comprehensive manner (Abt et al. , 2000; Sexton and Hay-ward, 1987).”
BackgroundCao, J., Lee, S., Chow, J. C., Cheng, Y., Ho, K., Fung, K., Liu, S. X., & Watson, J. G. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00336.x · Cited by 102
Indoor inhalation intake fractions of fine particulate matter: review of influencing factors
Hodas, N. O., Loh, M. M., Shin, H., Li, D., Bennett, D. H., McKone, T. E., Jolliet, O., Weschler, C. J., Jantunen, M. J., Lioy, P. J., et al. (2015) · Indoor Air · doi:10.1111/ina.12268 · Cited by 101
“…has provided particle size distributions and/or size-resolved emissions rates for a range of common indoor activities or sources including cooking (Abt et al., 2000; Hussein et al., 2006; Li and Hopke, 1993; Long et al., 2000; Ogulei et al., 2006; Wallace, 2006; Wallace et al., 2004), cleaning…”
Dutta, R. R., & Puzari, P. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.050 · Cited by 99
Polidori, A., Arhami, M., Sioutas, C., Delfino, R. J., & Allen, R. W. (2007) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2007.10465339 · Cited by 97
Sørensen, M., Loft, S. H., Andersen, H. V., Raaschou‐Nielsen, O., Skovgaard, L. T., Knudsen, L. E., Nielsen, I. V., & Hertel, O. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500419 · Cited by 97
“Other factors that influence the indoor air quality are air exchange rates, ventilation and indoor work (Thatcher and Layton, 1995; Abt et al., 2000).”
BackgroundImpact of biomass burning sources on seasonal aerosol air quality
Reisen, F., Meyer, C. P. M., & Keywood, M. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.11.004 · Cited by 96
Coombs, K., Chew, G. L., Schaffer, C., Ryan, P., Brokamp, C., Grinshpun, S. A., Adamkiewicz, G., Chillrud, S. N., Hedman, C. J., Colton, M. D., et al. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.02.136 · Cited by 96
“It has been shown in previous studies that both indoor (tobacco smoke, etc.) and outdoor sources (automobile exhaust, etc.) contribute to PM 2.5 concentrations in the indoor environment (Abt et al., 2000; Na and Cocker, 2005; Götschi et al., 2002).”
InfluentialSarnat, S. E., Coull, B. A., Ruiz-Rudolph, P., Koutrakis, P., & Suh, H. H. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464449 · Cited by 95
Self-citationParticulate pollution in different housing types in a UK suburban location
Nasir, Z. A., & Colbeck, I. (2013) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2012.12.042 · Cited by 93
“…include cooking, kerosene heating and wood burning (e.g. Sjaastad and Svendsen, 2008), while sources such as cleaning, dusting and vacuuming, showering, electric motors, movement of people and gas-to-particle conversion have also been investigated (e.g. Abt et al. 2000a and b; Waring et al., 2008).”
BackgroundINDAIR: A probabilistic model of indoor air pollution in UK homes
Dimitroulopoulou, S., ASHMORE, M. R., Hill, M. T. R., Byrne, M., & Kinnersley, R. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.05.047 · Cited by 92
Exposure to particle number, surface area and PM concentrations in pizzerias
Buonanno, G., Morawska, L., Stabile, L., & Viola, A. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.07.002 · Cited by 91
Arhami, M., Minguillón, M. C., Polidori, A., Schauer, J. J., Delfino, R. J., & Sioutas, C. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00620.x · Cited by 89
“, 2008), we estimated air exchange rates (AER) from CO measurements during periods affected by a dominant indoor source (Abt et al., 2000) and infiltration factors (Finf; defined as the equilibrium fraction of the outdoor species of interest that penetrate indoors and remain suspended) at each site.”
BackgroundDeposition of aerosol particles from a subway microenvironment in the human respiratory tract
Martins, V., Minguillón, M. C., Moreno, T., Querol, X., de Miguel, E., Capdevila, M., Centelles, S., & Lazaridis, M. (2015) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2015.08.008 · Cited by 95
“Abt et al. (2000a, 2000b) conducted an intensive study characterizing sources of indoor particles and they found that cooking activities, cleaning and the movement of people has a significant impact on indoor particle concentrations.”
BackgroundIndoor/outdoor particulate matter number and mass concentration in modern offices
Chatoutsidou, S. E., Ondráček, J., Tesař, O., Tørseth, K., Ždímal, V., & Lazaridis, M. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.05.023 · Cited by 97
Wheeler, A. J., Wallace, L. A., Kearney, J. P., Ryswyk, K. V., You, H., Kulka, R., Brook, J. R., & Xu, X. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.580798 · Cited by 87
“Very few studies have measured UFP in a large number of homes over extended periods, although they were included in early studies of 4 homes by Abt et al. (2000), 10 homes by Long et al. (2001), fourteen homes by Morawska et al. (2003), and thirty-six homes by Weichenthal et al. (2007).”
BackgroundMartuzevičius, D., Grinshpun, S. A., Lee, T., Hu, S., Biswas, P., Reponen, T. A., & LeMasters, G. K. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.05.009 · Cited by 87
“All rights reserved. doi:10.1016/j.atmosenv.2008.05.009 contribution of outdoor particles to the indoor particle concentration levels (Abt et al., 2000; Morawska et al., 2001; Vette et al., 2001; Riley et al., 2002; Franck et al., 2003; Cyrys et al., 2004; Maston, 2005; Meng et al., 2005; Hoek et…”
BackgroundInfluentialMartins, V., Faria, T., Diapouli, E., Manousakas, M. I., Eleftheriadis, K., Viana, M., & Almeida, S. M. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109203 · Cited by 85
Indoor Aerosol Modeling: Basic Principles and Practical Applications
Hussein, T., & Kulmala, M. (2007) · Water Air and Soil Pollution Focus · doi:10.1007/s11267-007-9134-x · Cited by 85
“A common example of multiple-component indoor air models is the sectional (size-resolved) indoor air model in which the dynamic behavior of indoor particle size distributions is the main interest (e.g. Asmi et al. 2004; Nazaroff 2004; Thatcher et al. 2002; Long et al. 2000; Abt et al. 2000; Thatcher and Layton 1995).”
BackgroundQi, M., Zhu, X., Du, W., Chen, Y., Chen, Y., Huang, T., Pan, X., Zhong, Q., Sun, X., Zeng, E. Y., et al. (2016) · Environmental Pollution · doi:10.1016/j.envpol.2016.10.035 · Cited by 84
“Other common sources include smoking, cooking fumes, and many other human activities (Abt et al., 2000; Kearney et al., 2014; Massey et al., 2016; Pagel et al., 2016).”
BackgroundIndoor PM2.5 in an urban zone with heavy wood smoke pollution: The case of Temuco, Chile
Jorquera, H., Barraza, F., Heyer, J., Valdivia, G. G., Schiappacasse, L., & Montoya, L. D. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2018.01.085 · Cited by 88
Shen, S., Jaques, P. A., Zhu, Y., Geller, M. D., & Sioutas, C. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00330-8 · Cited by 81
Chu, H., Liu, Y., Xu, N., & Xu, J. (2022) · Environmental Chemistry Letters · doi:10.1007/s10311-022-01546-2 · Cited by 79
Koehler, K. A., Good, N., Wilson, A., Mölter, A., Moore, B. F., Carpenter, T., Peel, J. L., & Volckens, J. (2018) · Indoor Air · doi:10.1111/ina.12533 · Cited by 79
“Median number of observations per participant; range 9 (3-13)”
BackgroundLunderberg, D. M., Liang, Y., Singer, B. C., Apte, J. S., Nazaroff, W. W., & Goldstein, A. H. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2308832120 · Cited by 80
“Applying source - attribution methods to Western residences has yielded estimates that approximately 50 to 80% of residential indoor PM 2.5 originates from outdoor PM 2.5 that penetrates indoors and remains suspended (20, 23–29).”
InfluentialViana, M., Rivas, I., Querol, X., Alástuey, A., Sunyer, J., Álvarez‐Pedrerol, M., Bouso, L., & Sioutas, C. (2014) · Atmospheric chemistry and physics · doi:10.5194/acp-14-4459-2014 · Cited by 83
“Quasi-UFPs are expected to penetrate indoors more efficiently because the effective penetration efficiency is known to be greatest for particles in the 100 to 200 nm range, where particle losses from diffusion and impaction are minimal (Abt et al., 2000).”
BackgroundImpact of wood combustion on indoor air quality
Vicente, E. D., Vicente, A., Evtyugina, M. G., Oduber, F., Amato, F., Querol, X., & Alves, C. A. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135769 · Cited by 80
Bouilly, J., Limam, K., Béghein, C., & Allard, F. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.04.033 · Cited by 75
Gurley, E. S., Salje, H., Homaira, N., Ram, P. K., Haque, R., Petri, W. A., Bresee, J., Moss, W. J., Luby, S. P., Breysse, P. N., et al. (2012) · Environmental Research · doi:10.1016/j.envres.2012.10.004 · Cited by 75
“Penetration of ambient pollution indoors has been established in other settings (Abt et al. 2000; Sapkota et al. 2005).”
Stephens, B., & Siegel, J. A. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2011.642825 · Cited by 73
“There are also many indoor sources of particles present in most indoor environments, particularly in residences (Abt et al. 2000; Afshari et al. 2005; Hussein et al. 2006; Wallace 2006).”
BackgroundMeier, R., Eeftens, M., Phuleria, H. C., Ineichen, A., Corradi, E., Davey, M. E., Fierz, M., Ducret-Stich, R. E., Aguilera, I., Schindler, C., et al. (2015) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2015.3 · Cited by 74
Meng, Q. Y., Turpin, B. J., Lee, J., Polidori, A., Weisel, C. P., Morandi, M. T., Colome, S. D., Zhang, J. J., Stock, T. H., & Winer, A. (2007) · Environmental Science & Technology · doi:10.1021/es070037k · Cited by 75
Measurements of children's exposures to particles and nitrogen dioxide in Santiago, Chile
Rojas‐Bracho, L., Suh, H. H., Oyola, P., & Koutrakis, P. (2002) · The Science of The Total Environment · doi:10.1016/s0048-9697(01)00987-1 · Cited by 73
Self-citationHussein, T., Korhonen, H., Herrmann, E., Hämeri, K. J., Lehtinen, K. E. J., & Kulmala, M. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500421513 · Cited by 72
“…other hand, fine aerosol particles are typically generated with huge amounts during cooking, sauna heating, and fireplace (Afshari et al. 2005; Hussein et al. 2005; Dennekamp et al. 2001; Abt et al. 2000a and 2000b; Flückiger et al. 2000; Wallace 2000; Sohn et al. 1999; Siegmann and Sattler 1996).”
BackgroundThe impact of particle filtration on indoor air quality in a classroom near a highway
van der Zee, S. C., Strak, M., Dijkema, M., Brunekreef, B., & Janssen, N. (2016) · Indoor Air · doi:10.1111/ina.12308 · Cited by 72
“High ventilation rates contribute to the effective removal of indoor-generated particles (Abt et al., 2000; Chen and Zhao, 2011; Goyal and Khare, 2009); consequently, low ventilation rates result in a higher concentration of indoor-generated particles.”
Long, C. M., & Sarnat, J. A. (2004) · Aerosol Science and Technology · doi:10.1080/027868290502281 · Cited by 72
“Air exchange rates (AERs) were measured in each home every 5 min using continuous injection of sulfur hexafluoride (SF6) tracer gas and measurement via a photoacoustic monitor (Abt et al. 2000a; Long et al. 2000).”
BackgroundMethodInfluentialBrown, K. W., Sarnat, J. A., Suh, H. H., Coull, B. A., Spengler, J. D., & Koutrakis, P. (2008) · Journal of Environmental Monitoring · doi:10.1039/b805991h · Cited by 70
Self-citationPredicting the energy use and operation cost of HVAC air filters
Montgomery, J. F., Green, S., Rogak, S. N., & Bartlett, K. H. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.01.001 · Cited by 70
Metadata
- Authors
- Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P.
- Affiliations
- Harvard University (US)
- Corresponding author
- Abt, Eileen
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-02
- Volume
- 34
- Issue
- 17
- Pages
- 3579-3587
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2068336202
- Cited by
- 411
- References
- 17
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 15 · 2021: 29 · 2020: 23 · 2019: 18 · 2018: 19 · 2017: 11 · 2016: 16 · 2015: 29 · 2014: 21 · 2013: 22 · 2012: 19
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air pollution, particulate matter, cooking emissions, indoor work, air exchange rate, penetration efficiency, particle size distribution, particle decay rates, gravitational settling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.